Categories
No result found for your search.
Need help? Contact us
+90 542 203 61013
info@stoklink.com
Your cart is empty
- Home
- ABB
- ABB 1SDA067440R1 XT1S 160 TMD 63-630 4p F F 4-Pole 63A Fixed Molded Case Circuit Breaker ABB 1SDA067440R1 XT1S 160 TMD 63-630 4p F F 4-Pole 63A Fixed Molded Case Circuit Breaker
Circuit Breakers & Protection
/
Molded Case Circuit Breakers (MCCB)
/
ABB Tmax XT MCCBs
/
ABB 1SDA067440R1 XT1S 160 TMD 63-630 4p F F 4-Pole 63A Fixed Molded Case Circuit Breaker
% $-174.54
ABB 1SDA067440R1 XT1S 160 TMD 63-630 4p F F 4-Pole 63A Fixed Molded Case Circuit Breaker
Brand:
ABB
Reference No:
1SDA067440R1
Catalog No:
XT1S 160 TMD 63-630 4p F F
Series:
Tmax XT1
Tariff Code (HS):
85362090
Get Quote
Rated Current:
63
Breaking Capacity:
(400 V AC) 50 kA
Breaking Type:
TMD
Poles:
4P
Stock:
24
Delivery time:
1-2 business day(s)
Shipping Origin:
Türkiye EXW
$174.54
- Description
The ABB 1SDA067440R1 (XT1S 160 TMD 63-630 4p F F) is a 63 A, 4-pole, fixed-mounted molded case circuit breaker (MCCB) from the Tmax XT1 range, ABB's current-generation MCCB series (160 A frame). It is fitted with a thermal-magnetic (TMD) trip unit and is rated 50 kA Icu at 400 V AC. Weight is 1.4 kg.
Technical Specifications
| Catalog Number | XT1S 160 TMD 63-630 4p F F |
| SKU | 1SDA067440R1 |
| Brand | ABB |
| Series | Tmax XT1 |
| Product Type | Molded Case Circuit Breaker (MCCB) |
| Model | XT1S |
| Rated Current | 63 A |
| Magnetic Trip (Im) | 630 A |
| Number of Poles | 4 |
| Trip Unit | TMD (Thermal-Magnetic) |
| Mounting Type | Fixed (F F) |
| Weight | 1.4 kg |
| EAN / Barcode | 8015644013349 |
Certifications & Standards
- RoHS: Compliant with the Restriction of Hazardous Substances Directive, ensuring reduced environmental impact
- REACH: Compliant with EU REACH regulation on chemical safety and substances of concern
- EU Directive 2011/65/EU & Amendment 2015/863: Fully compliant as of July 22, 2019, confirming restriction of hazardous substances in electrical and electronic equipment
Selection Notes
- Rated current is 63 A with a magnetic trip (Im) of 630 A; check it against the continuous load current of the circuit being protected.
- Icu is 50 kA at 400 V AC; confirm it is equal to or higher than the prospective fault current at the installation point.
- This is a 4-pole version; use it where the neutral conductor must be switched, and confirm the pole count matches the system. Mounting is fixed (not plug-in or withdrawable).
- The TMD trip unit is thermal-magnetic; check the thermal setting and magnetic trip values in the ABB catalog against the load and the protection coordination plan.
Technical Details
Rated Current (Ampere)
63
Breaking Capacity (kA)
(400 V AC) 50 kA
Mounting Type
Fixed
Catalog No
XT1S 160 TMD 63-630 4p F F
Number of Poles
4P
Delivery Date (Days)
1-2 days
Model Number
XT1S
Tariff Code
85362090