- Home
- All Collections
- Residual Current Devices (RCD)
Residual Current Devices (RCD)
ABB 2CSM142120R1201 RD2 Type A 2000mA 230-400V AC DIN-Rail Residual Current Monitoring Relay
ABB 2CSR255080R3254 DS201 C25 AC300 25A 2P 6kA 230V AC Earth Leakage Circuit Breaker
ABB 2CSR255080R3164 DS201 C16 AC300 1P+N 16A 10kA Type AC 300mA Earth Leakage Circuit Breaker RCBO
ABB 2CSR255080R1404 DS201 C40 AC30 1P+N 40A 30mA 10kA Type AC Earth Leakage Circuit Breaker RCBO
ABB 2CSR255080R1204 DS201 C20 AC30 1P+N 20A 10kA Type AC 30mA Earth Leakage Circuit Breaker RCBO
ABB 2CSR255080R1164 DS201 C16 AC30 1P+N 16A 30mA Type AC 6kA Earth Leakage Circuit Breaker RCBO
ABB 2CSR255080R1104 DS201 C10 AC30 1P+N 10A 30mA Type AC 10kA Earth Leakage Circuit Breaker RCBO
ABB 2CSR255080R1064 DS201 C6 AC30 1P+N 6A 30mA 10kA Type AC Earth Leakage Circuit Breaker RCBO
ABB 2CSB204001R3400 DDA204 AC-40/0.3 4P 40A 300mA Type AC Residual Current Circuit Breaker Module
ABB 2CSB204001R1630 DDA204 AC-63/0.03 4P 63A 30mA Type AC Residual Current Circuit Breaker Module
ABB 2CSB204001R1400 DDA204 AC-40/0.03 4P 40A 30mA Type AC Residual Current Circuit Breaker Module
ABB 2CSB204001R1250 DDA204 AC-25/0.03 4P 25A 30mA Type AC Residual Current Circuit Breaker Module
ABB 2CSB203001R1630 DDA203 AC-63/0.03 3P 63A 30mA Type AC Residual Current Circuit Breaker RCCB Module
ABB 2CSB202001R3250 DDA202 AC-25/0.3 2P 25A 300mA Type AC Residual Current Circuit Breaker Module
ABB 2CSB202001R1400 DDA202 AC-40/0.03 2P 40A 30mA Type AC Residual Current Circuit Breaker Module
ABB 2CSB202001R1250 DDA202 AC-25/0.03 2P 25A 30mA Type AC Residual Current Circuit Breaker Module
ABB 2CSF204568R3400 F204 B-40/0.3 4P 40A 300mA Type B Residual Current Circuit Breaker
ABB 2CSF204568R1630 F204 B-63/0.03 4P 63A 30mA DIN-Rail Residual Current Circuit Breaker (RCCB)
ABB 2CSF204568R1400 F204 B-40/0.03 4P 40A 30mA DIN-Rail Residual Current Circuit Breaker (RCCB)
ABB 2CSF204568R1250 F204 B-25/0.03 4P 25A 30mA DIN-Rail Residual Current Circuit Breaker
Residual current devices (RCD) from ABB, Siemens and Schneider Electric detect earth leakage and disconnect the circuit before it becomes a shock or fire risk. The range covers RCCBs, RCBOs and add-on blocks in 1+N, 2, 3 and 4 poles, with sensitivities from 30 mA to 300 mA. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- RCCB (Residual Current Circuit Breakers) – earth leakage protection only, used with an upstream MCB or fuse.
- RCBO (Residual Current Breakers with Overcurrent Protection) – leakage, overload and short-circuit protection in one device.
- RCD Add-on Blocks & Earth Leakage Relays – blocks that clip onto an MCB, and relays for leakage monitoring.
How to choose
- Sensitivity: 30 mA for personal protection, 100 to 300 mA for fire protection and selectivity.
- Type: AC, A or B, depending on whether the load can produce pulsating or smooth DC leakage, as with drives and inverters.
- Rated current and poles: the RCD must carry the total load of the circuits behind it. Match 2P to single-phase and 4P to three-phase with neutral.
- Standard: IEC 61008-1 for RCCBs and IEC 61009-1 for RCBOs.
- Selectivity: use a time-delayed or S-type RCD upstream of an instantaneous one.
FAQ
What is the difference between an RCCB and an RCBO?
An RCCB only detects earth leakage, so it needs a separate MCB or fuse for overload and short-circuit protection. An RCBO combines both in one module.
Which RCD type do I need for a variable frequency drive?
Drives can produce DC leakage components that Type AC and Type A devices may not detect. Type B is normally specified for three-phase drive circuits. Check the drive manual.
Do you ship RCDs outside Turkey?
Yes. Stoklink ships worldwide from Turkey, EXW. Lead time depends on distributor stock, and we quote bulk project volumes on request.