Residual Current Devices (RCD)
ABB 2CSF202568R1250 F202 B-25/0.03 2P 25A 30mA DIN-Rail Residual Current Circuit Breaker
ABB 2CSF202568R1160 F202 B-16/0.03 2P 16A 30mA DIN-Rail Residual Current Circuit Breaker
ABB 2CSF204401R1900 F204 A-100/0.03 AP-R 4P 100A 30mA Type A AP-R Residual Current Circuit Breaker
ABB 2CSF204401R1630 F204 A-63/0.03 AP-R 4P 63A 30mA Type A-APR Residual Current Circuit Breaker
ABB 2CSF204401R1400 F204 A-40/0.03 AP-R 4P 40A 30mA Type A-APR Residual Current Circuit Breaker
ABB 2CSF204401R1250 F204 A-25/0.03 AP-R 4P 25A 30mA Type A-APR Residual Current Circuit Breaker
ABB 2CSF202401R1630 F202 A-63/0.03 AP-R 2P 63A 30mA Type A-APR Residual Current Circuit Breaker
ABB 2CSF202401R1400 F202 A-40/0.03 AP-R 2P 40A 30mA Residual Current Circuit Breaker
ABB 2CSF202401R1250 F202 A-25/0.03 AP-R 2P 25A 30mA Type A-APR Residual Current Circuit Breaker
ABB 2CSF204201R3900 F204 A S-100/0.3 4P 100A Residual Current Circuit Breaker (RCCB) DIN-Rail
ABB 2CSF204201R3400 F204 A S-40/0.3 4P 40A 300mA DIN-Rail Residual Current Circuit Breaker
ABB 2CSF204102R1630 FH204 A-63/0.03 4P 63A 30mA 6kA Type A Residual Current Circuit Breaker
ABB 2CSF204102R1400 FH204 A-40/0.03 4P 40A 6kA 30mA Residual Current Circuit Breaker RCCB
ABB 2CSF204102R1250 FH204 A-25/0.03 4P 25A 6kA Residual Current Circuit Breaker
ABB 2CSF202102R1630 FH202 A-63/0.03 2P 63A 30mA Type A Residual Current Circuit Breaker
ABB 2CSF202102R1400 FH202 A-40/0.03 2P 40A 6kA 30mA DIN-Rail Residual Current Circuit Breaker (RCCB)
ABB 2CSF202102R1250 FH202 A-25/0.03 2P 25A 30mA 6kA Type A Residual Current Circuit Breaker
ABB 2CSF204001R3900 F204 AC-100/0.3 4P 100A RCCB Residual Current Circuit Breaker DIN-Rail
ABB 2CSF204001R1950 F204 AC-125/0.03 4P 125A 30mA 10kA Residual Current Circuit Breaker
ABB 2CSF204001R1900 F204 AC-100/0.03 4P 100A 30mA DIN-Rail Residual Current Circuit Breaker (RCCB)
Residual current devices (RCD) from ABB, Siemens and Schneider Electric detect earth leakage and disconnect the circuit before it becomes a shock or fire risk. The range covers RCCBs, RCBOs and add-on blocks in 1+N, 2, 3 and 4 poles, with sensitivities from 30 mA to 300 mA. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- RCCB (Residual Current Circuit Breakers) – earth leakage protection only, used with an upstream MCB or fuse.
- RCBO (Residual Current Breakers with Overcurrent Protection) – leakage, overload and short-circuit protection in one device.
- RCD Add-on Blocks & Earth Leakage Relays – blocks that clip onto an MCB, and relays for leakage monitoring.
How to choose
- Sensitivity: 30 mA for personal protection, 100 to 300 mA for fire protection and selectivity.
- Type: AC, A or B, depending on whether the load can produce pulsating or smooth DC leakage, as with drives and inverters.
- Rated current and poles: the RCD must carry the total load of the circuits behind it. Match 2P to single-phase and 4P to three-phase with neutral.
- Standard: IEC 61008-1 for RCCBs and IEC 61009-1 for RCBOs.
- Selectivity: use a time-delayed or S-type RCD upstream of an instantaneous one.
FAQ
What is the difference between an RCCB and an RCBO?
An RCCB only detects earth leakage, so it needs a separate MCB or fuse for overload and short-circuit protection. An RCBO combines both in one module.
Which RCD type do I need for a variable frequency drive?
Drives can produce DC leakage components that Type AC and Type A devices may not detect. Type B is normally specified for three-phase drive circuits. Check the drive manual.
Do you ship RCDs outside Turkey?
Yes. Stoklink ships worldwide from Turkey, EXW. Lead time depends on distributor stock, and we quote bulk project volumes on request.