Filter

Residual Current Devices (RCD)

Filter
Showing 1 - 220 of 277 items

Schneider Electric A9R14480 iID 4P 80A Residual Current Circuit Breaker Acti 9

Reference No: A9R14480
Rated Current (A): 80
Number of Poles: 4P
51 pcs in stock
$105.65

Schneider Electric A9R11491 iID 4P 100A Residual Current Circuit Breaker Acti 9

Reference No: A9R11491
Rated Current (A): 100
Number of Poles: 4P
100 pcs in stock
$202.30

Schneider Electric A9R11480 iID 4P 80A Residual Current Circuit Breaker Acti 9

Reference No: A9R11480
Rated Current (A): 80
Number of Poles: 4P
78 pcs in stock
$123.98

Schneider Electric A9D34616 iDPNa Vigi 1P+N 16A 4.5kA Residual Current Breaker with Overcurrent Protection RCBO

Reference No: A9D34616
Rated Current (A): 16
Number of Poles: 1P+N
56 pcs in stock
$54.65

Schneider Electric A9D34610 iDPNa Vigi 1P+N 10A 4.5kA Acti9 Residual Current Breaker with Overcurrent Protection RCBO

Reference No: A9D34610
Rated Current (A): 10
Number of Poles: 1P+N
100 pcs in stock
$55.53

Schneider Electric A9D31620 iDPN N Vigi 1P+N 20A 6kA Residual Current Breaker with Overcurrent Protection RCBO

Reference No: A9D31620
Rated Current (A): 20
Number of Poles: 1P+N
100 pcs in stock
$62.23

Schneider Electric A9DE3725 iCV40N 3P+N 25A 6kA RCBO Residual Current Breaker with Overcurrent Protection

Reference No: A9DE3725
Rated Current (A): 25
Number of Poles: 3P+N
6 pcs in stock
$111.27

Schneider Electric LV481010 Vigirex RHB Type B 30 mA-3 A 100-250 V AC/DC Residual Current Monitoring Relay

Reference No: LV481010
Rated Voltage (VAC): 100/250 V AC/DC
0 pcs in stock
$1,147.99

Schneider Electric LV481004 Vigirex RMH 30 mA-30 A 220-240 V AC Multiplexed Residual Current Monitoring Relay

Reference No: LV481004
Rated Voltage (VAC): 220/240 V AC
0 pcs in stock
$735.60

Schneider Electric LV481003 Vigirex RHU Modbus 30 mA-30 A 220-240 V AC Residual Current Monitoring Relay

Reference No: LV481003
Rated Voltage (VAC): 220/240 V AC
0 pcs in stock
$656.54

Schneider Electric LV481001 Vigirex RHUs 30 mA-30 A 0-4.5 s 220-240 V AC Residual Current Monitoring Relay

Reference No: LV481001
Rated Voltage (VAC): 220/240 V AC
0 pcs in stock
$631.24

ABB 2CSF204001R3400 F204 AC-40/0.3 4P 40A 0.3A DIN-Rail Residual Current Circuit Breaker (RCCB)

Reference No: 2CSF204001R3400
Catalog No: F204 AC-40/0.3
Rated Current (A): 40
Number of Poles: 4P
3 pcs in stock
$75.35

ABB 2CSF204001R1400 F204 AC-40/0.03 4P 40A 30mA DIN-Rail Residual Current Circuit Breaker

Reference No: 2CSF204001R1400
Catalog No: F204 AC-40/0.03
Rated Current (A): 40
Number of Poles: 4P
1 pcs in stock
$118.66

ABB 2CSF202001R1400 F202 AC-40/0.03 2P 40A 30mA Type AC Residual Current Circuit Breaker

Reference No: 2CSF202001R1400
Catalog No: F202 AC-40/0.03
Rated Current (A): 40
Number of Poles: 2P
0 pcs in stock
$64.40

ABB 2CSF202001R1250 F202 AC-25/0.03 2P 25A 30mA DIN-Rail Residual Current Circuit Breaker

Reference No: 2CSF202001R1250
Catalog No: F202 AC-25/0.03
Rated Current (A): 25
Number of Poles: 2P
0 pcs in stock
$70.22

ABB 2CSF204001R1250 F204 AC-25/0.03 4P 25A RCCB DIN-Rail Residual Current Circuit Breaker

Reference No: 2CSF204001R1250
Catalog No: F204 AC-25/0.03
Rated Current (A): 25
Number of Poles: 4P
0 pcs in stock
$64.40

ABB 2CSF204001R3250 F204 AC-25/0.3 4P 25A Residual Current Circuit Breaker (RCCB) DIN-Rail

Reference No: 2CSF204001R3250
Catalog No: F204 AC-25/0.3
Rated Current (A): 25
Number of Poles: 4P
1 pcs in stock
$57.95

ABB 2CSJ203001R0002 RD3P 500mA 230-400V AC DIN-Rail Residual Current Monitoring Relay

Reference No: 2CSJ203001R0002
Catalog No: RD3P
Rated Voltage (VAC): 230/400 V AC
0 pcs in stock
$415.96

ABB 2CSJ202001R0002 RD3M 1-500mA 230-400V AC DIN-Rail Residual Current Monitoring Relay

Reference No: 2CSJ202001R0002
Catalog No: RD3M
Rated Voltage (VAC): 230/400 V AC
0 pcs in stock
$408.23

ABB 2CSJ201001R0002 RD3 Type A 500mA 230-400V AC 3.6W Residual Current Monitor

Reference No: 2CSJ201001R0002
Catalog No: RD3
Rated Voltage (VAC): 230/400 V AC
169 pcs in stock
$257.44

Residual current devices (RCD) from ABB, Siemens and Schneider Electric detect earth leakage and disconnect the circuit before it becomes a shock or fire risk. The range covers RCCBs, RCBOs and add-on blocks in 1+N, 2, 3 and 4 poles, with sensitivities from 30 mA to 300 mA. Stoklink ships worldwide from Turkey and quotes project volumes on request.

What's in this range

How to choose

  • Sensitivity: 30 mA for personal protection, 100 to 300 mA for fire protection and selectivity.
  • Type: AC, A or B, depending on whether the load can produce pulsating or smooth DC leakage, as with drives and inverters.
  • Rated current and poles: the RCD must carry the total load of the circuits behind it. Match 2P to single-phase and 4P to three-phase with neutral.
  • Standard: IEC 61008-1 for RCCBs and IEC 61009-1 for RCBOs.
  • Selectivity: use a time-delayed or S-type RCD upstream of an instantaneous one.

FAQ

What is the difference between an RCCB and an RCBO?

An RCCB only detects earth leakage, so it needs a separate MCB or fuse for overload and short-circuit protection. An RCBO combines both in one module.

Which RCD type do I need for a variable frequency drive?

Drives can produce DC leakage components that Type AC and Type A devices may not detect. Type B is normally specified for three-phase drive circuits. Check the drive manual.

Do you ship RCDs outside Turkey?

Yes. Stoklink ships worldwide from Turkey, EXW. Lead time depends on distributor stock, and we quote bulk project volumes on request.