Filter

Residual Current Devices (RCD)

Filter
Showing 1 - 200 of 277 items

Schneider Electric A9R61463 iID 4P 63A Residual Current Circuit Breaker Acti 9

Reference No: A9R61463
Rated Current (A): 63
Number of Poles: 4P
100 pcs in stock
$97.49

Schneider Electric A9R61425 iID 4P 25A Residual Current Circuit Breaker Acti 9 Series

Reference No: A9R61425
Rated Current (A): 25
Number of Poles: 4P
67 pcs in stock
$81.04

Schneider Electric A9R61240 iID 2P 40A Residual Current Circuit Breaker (RCCB) Acti 9

Reference No: A9R61240
Rated Current (A): 40
Number of Poles: 2P
100 pcs in stock
$60.35

Schneider Electric A9R61225 iID 2P 25A Residual Current Circuit Breaker (RCCB) Acti 9

Reference No: A9R61225
Rated Current (A): 25
Number of Poles: 2P
100 pcs in stock
$57.90

Schneider Electric A9R44463 iID 4P 63A Residual Current Circuit Breaker (RCCB) Acti9

Reference No: A9R44463
Rated Current (A): 63
Number of Poles: 4P
100 pcs in stock
$65.38

Schneider Electric A9R44440 iID 4P 40A Residual Current Circuit Breaker (RCCB) Acti 9

Reference No: A9R44440
Rated Current (A): 40
Number of Poles: 4P
100 pcs in stock
$57.41

Schneider Electric A9R44425 iID 4P 25A Residual Current Circuit Breaker Acti 9

Reference No: A9R44425
Rated Current (A): 25
Number of Poles: 4P
100 pcs in stock
$55.92

Schneider Electric A9R44263 iID 2P 63A Residual Current Circuit Breaker Acti 9

Reference No: A9R44263
Rated Current (A): 63
Number of Poles: 2P
1 pcs in stock
$49.34

Schneider Electric A9R44240 iID 2P 40A Residual Current Circuit Breaker Acti 9

Reference No: A9R44240
Rated Current (A): 40
Number of Poles: 2P
71 pcs in stock
$41.35

Schneider Electric A9R44225 iID 2P 25A Residual Current Circuit Breaker Acti 9

Reference No: A9R44225
Rated Current (A): 25
Number of Poles: 2P
100 pcs in stock
$39.97

Schneider Electric A9R41463 iID 4P 63A Residual Current Circuit Breaker Acti 9

Reference No: A9R41463
Rated Current (A): 63
Number of Poles: 4P
100 pcs in stock
$71.29

Schneider Electric A9R41440 iID 4P 40A Residual Current Circuit Breaker Acti 9

Reference No: A9R41440
Rated Current (A): 40
Number of Poles: 4P
100 pcs in stock
$60.85

Schneider Electric A9R41425 iID 4P 25A 10kA 400/415V AC Earth Leakage Protection RCCB DIN Rail

Reference No: A9R41425
Rated Current (A): 25
Rated Voltage (VAC): 400/415 V AC
Number of Poles: 4P
100 pcs in stock
$60.17

Schneider Electric A9R41263 iID 2P 63A Residual Current Circuit Breaker (RCCB) Acti9

Reference No: A9R41263
Rated Current (A): 63
Number of Poles: 2P
100 pcs in stock
$55.64

Schneider Electric A9R41240 iID 2P 40A Residual Current Circuit Breaker Acti 9

Reference No: A9R41240
Rated Current (A): 40
Number of Poles: 2P
100 pcs in stock
$51.00

Schneider Electric A9R41225 iID 2P 25A Residual Current Circuit Breaker (RCCB) Acti 9

Reference No: A9R41225
Rated Current (A): 25
Number of Poles: 2P
100 pcs in stock
$42.34

Schneider Electric A9R35463 iID 4P 63A Residual Current Circuit Breaker (RCCB) Acti 9

Reference No: A9R35463
Rated Current (A): 63
Number of Poles: 4P
52 pcs in stock
$162.91

Schneider Electric A9R35440 iID 4P 40A Residual Current Circuit Breaker Acti 9

Reference No: A9R35440
Rated Current (A): 40
Number of Poles: 4P
84 pcs in stock
$146.80

Schneider Electric A9R34463 iID 4P 63A Residual Current Circuit Breaker Acti9 Series

Reference No: A9R34463
Rated Current (A): 63
Number of Poles: 4P
100 pcs in stock
$94.92

Schneider Electric A9R14491 iID 4P 100A Residual Current Circuit Breaker Acti 9

Reference No: A9R14491
Rated Current (A): 100
Number of Poles: 4P
83 pcs in stock
$165.60

Residual current devices (RCD) from ABB, Siemens and Schneider Electric detect earth leakage and disconnect the circuit before it becomes a shock or fire risk. The range covers RCCBs, RCBOs and add-on blocks in 1+N, 2, 3 and 4 poles, with sensitivities from 30 mA to 300 mA. Stoklink ships worldwide from Turkey and quotes project volumes on request.

What's in this range

How to choose

  • Sensitivity: 30 mA for personal protection, 100 to 300 mA for fire protection and selectivity.
  • Type: AC, A or B, depending on whether the load can produce pulsating or smooth DC leakage, as with drives and inverters.
  • Rated current and poles: the RCD must carry the total load of the circuits behind it. Match 2P to single-phase and 4P to three-phase with neutral.
  • Standard: IEC 61008-1 for RCCBs and IEC 61009-1 for RCBOs.
  • Selectivity: use a time-delayed or S-type RCD upstream of an instantaneous one.

FAQ

What is the difference between an RCCB and an RCBO?

An RCCB only detects earth leakage, so it needs a separate MCB or fuse for overload and short-circuit protection. An RCBO combines both in one module.

Which RCD type do I need for a variable frequency drive?

Drives can produce DC leakage components that Type AC and Type A devices may not detect. Type B is normally specified for three-phase drive circuits. Check the drive manual.

Do you ship RCDs outside Turkey?

Yes. Stoklink ships worldwide from Turkey, EXW. Lead time depends on distributor stock, and we quote bulk project volumes on request.