- Home
- All Collections
- Residual Current Devices (RCD)
Residual Current Devices (RCD)
Schneider Electric EZ9R69463 Easy9 Pro 4P 63A Residual Current Circuit Breaker (RCCB)
Schneider Electric EZ9R69440 Easy9 Pro 4P 40A Residual Current Circuit Breaker RCCB
Schneider Electric EZ9R69425 Easy9 Pro RCCB 4P 25A Residual Current Circuit Breaker
Schneider Electric EZ9R69240 Easy9 Pro RCCB 2P 40A Residual Current Circuit Breaker
Schneider Electric EZ9R69225 Easy9 Pro RCCB 2P 25A Residual Current Circuit Breaker
Schneider Electric EZ9R39463 Easy9 Pro RCCB 4P 63A Residual Current Circuit Breaker
Schneider Electric EZ9R39440 Easy9 Pro RCCB 4P 40A Residual Current Circuit Breaker
Schneider Electric EZ9R39425 Easy9 Pro RCCB 4P 25A Residual Current Circuit Breaker
Schneider Electric EZ9R39263 Easy9 Pro RCCB 2P 63A Residual Current Circuit Breaker
Schneider Electric EZ9R39240 Easy9 Pro RCCB 4P Residual Current Circuit Breaker
Schneider Electric EZ9R39225 Easy9 Pro RCCB 2P 25A Residual Current Circuit Breaker
Schneider Electric EZ9R63463 Easy9 RCCB 4P 63A Residual Current Circuit Breaker
Schneider Electric EZ9R63440 Easy9 RCCB 4P 40A 400V Residual Current Circuit Breaker
Schneider Electric EZ9R63240 Easy9 RCCB 2P 40A 230V Residual Current Circuit Breaker
Schneider Electric EZ9R05463 Easy9 RCCB Industrial Electrical Component
Schneider Electric EZ9R05440 Easy9 RCCB 4P 40A 30mA Residual Current Circuit Breaker
Schneider Electric EZ9R05425 Easy9 RCCB Residual Current Circuit Breaker
Schneider Electric EZ9R05263 Easy9 RCCB Industrial Electrical Component
Schneider Electric EZ9R05240 Easy9 RCCB 2P 40A 230V Residual Current Device
Schneider Electric EZ9R05225 Easy9 RCCB 2P 25A 230V AC DIN Rail Residual Current Circuit Breaker
Residual current devices (RCD) from ABB, Siemens and Schneider Electric detect earth leakage and disconnect the circuit before it becomes a shock or fire risk. The range covers RCCBs, RCBOs and add-on blocks in 1+N, 2, 3 and 4 poles, with sensitivities from 30 mA to 300 mA. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- RCCB (Residual Current Circuit Breakers) – earth leakage protection only, used with an upstream MCB or fuse.
- RCBO (Residual Current Breakers with Overcurrent Protection) – leakage, overload and short-circuit protection in one device.
- RCD Add-on Blocks & Earth Leakage Relays – blocks that clip onto an MCB, and relays for leakage monitoring.
How to choose
- Sensitivity: 30 mA for personal protection, 100 to 300 mA for fire protection and selectivity.
- Type: AC, A or B, depending on whether the load can produce pulsating or smooth DC leakage, as with drives and inverters.
- Rated current and poles: the RCD must carry the total load of the circuits behind it. Match 2P to single-phase and 4P to three-phase with neutral.
- Standard: IEC 61008-1 for RCCBs and IEC 61009-1 for RCBOs.
- Selectivity: use a time-delayed or S-type RCD upstream of an instantaneous one.
FAQ
What is the difference between an RCCB and an RCBO?
An RCCB only detects earth leakage, so it needs a separate MCB or fuse for overload and short-circuit protection. An RCBO combines both in one module.
Which RCD type do I need for a variable frequency drive?
Drives can produce DC leakage components that Type AC and Type A devices may not detect. Type B is normally specified for three-phase drive circuits. Check the drive manual.
Do you ship RCDs outside Turkey?