Categories
No result found for your search.
Need help? Contact us
+90 542 203 61013
info@stoklink.com
Your cart is empty
- Home
- All Collections
- RCCB (Residual Current Circuit Breakers)
Circuit Breakers & Protection
/
Residual Current Devices (RCD)
/
RCCB (Residual Current Circuit Breakers)
Filter
RCCB (Residual Current Circuit Breakers)
ABB 2CSF204568R1630 F204 B-63/0.03 4P 63A 30mA DIN-Rail Residual Current Circuit Breaker (RCCB)
ABB 2CSF204568R1400 F204 B-40/0.03 4P 40A 30mA DIN-Rail Residual Current Circuit Breaker (RCCB)
ABB 2CSF204568R1250 F204 B-25/0.03 4P 25A 30mA DIN-Rail Residual Current Circuit Breaker
ABB 2CSF202568R1250 F202 B-25/0.03 2P 25A 30mA DIN-Rail Residual Current Circuit Breaker
ABB 2CSF202568R1160 F202 B-16/0.03 2P 16A 30mA DIN-Rail Residual Current Circuit Breaker
ABB 2CSF204401R1900 F204 A-100/0.03 AP-R 4P 100A 30mA Type A AP-R Residual Current Circuit Breaker
ABB 2CSF204401R1630 F204 A-63/0.03 AP-R 4P 63A 30mA Type A-APR Residual Current Circuit Breaker
ABB 2CSF204401R1400 F204 A-40/0.03 AP-R 4P 40A 30mA Type A-APR Residual Current Circuit Breaker
ABB 2CSF204401R1250 F204 A-25/0.03 AP-R 4P 25A 30mA Type A-APR Residual Current Circuit Breaker
ABB 2CSF202401R1630 F202 A-63/0.03 AP-R 2P 63A 30mA Type A-APR Residual Current Circuit Breaker
ABB 2CSF202401R1400 F202 A-40/0.03 AP-R 2P 40A 30mA Residual Current Circuit Breaker
ABB 2CSF202401R1250 F202 A-25/0.03 AP-R 2P 25A 30mA Type A-APR Residual Current Circuit Breaker
ABB 2CSF204201R3900 F204 A S-100/0.3 4P 100A Residual Current Circuit Breaker (RCCB) DIN-Rail
ABB 2CSF204201R3400 F204 A S-40/0.3 4P 40A 300mA DIN-Rail Residual Current Circuit Breaker
ABB 2CSF204102R1630 FH204 A-63/0.03 4P 63A 30mA 6kA Type A Residual Current Circuit Breaker
ABB 2CSF204102R1400 FH204 A-40/0.03 4P 40A 6kA 30mA Residual Current Circuit Breaker RCCB
ABB 2CSF204102R1250 FH204 A-25/0.03 4P 25A 6kA Residual Current Circuit Breaker
ABB 2CSF202102R1630 FH202 A-63/0.03 2P 63A 30mA Type A Residual Current Circuit Breaker
ABB 2CSF202102R1400 FH202 A-40/0.03 2P 40A 6kA 30mA DIN-Rail Residual Current Circuit Breaker (RCCB)
ABB 2CSF202102R1250 FH202 A-25/0.03 2P 25A 30mA 6kA Type A Residual Current Circuit Breaker
Residual current circuit breakers (RCCB) from ABB, Siemens and Schneider Electric protect people and installations against earth leakage on DIN-rail panels. The range includes F200, FH200, 5SV3, 5SV5, Acti 9 iID and Easy9 Pro in 2-pole, 4-pole and 1+N versions, with sensitivities from 30 mA to 300 mA. Stoklink ships worldwide from Turkey and quotes project volumes.
What's in this range
- ABB F200 and FH200 series in Type AC, A and B, including high-current versions up to 125 A.
- Siemens SENTRON 5SV3 and 5SV5 devices in 2P and 4P, 230 V and 400 V.
- Schneider Electric Acti 9 iID and Easy9 RCCBs.
- Type B devices for drive circuits.
How to choose
- Rated current: at least the total load current of the downstream circuits.
- Sensitivity: 30 mA for personal protection, 300 mA for fire protection or as a selective upstream device.
- Type: AC for resistive loads, A for electronics, B for drives and inverters.
- Short-circuit protection: an RCCB has none. Pair it with an upstream MCB or fuse.
- Poles: 2P for single-phase, 4P for three-phase with neutral.
FAQ
Can an RCCB replace an MCB?
No. An RCCB does not trip on overload or short circuit. It must be protected by an upstream MCB or fuse.
What does Type A mean on an RCCB?
Type A detects sinusoidal AC and pulsating DC residual currents. Type AC detects sinusoidal AC only.
Can I order RCCBs for a project in bulk?
Yes. Request a quote with the part numbers and quantities. Stoklink ships from Turkey, EXW.