Categories
No result found for your search.
Need help? Contact us
+90 542 203 61013
info@stoklink.com
Your cart is empty
- Home
- All Collections
- RCCB (Residual Current Circuit Breakers)
Circuit Breakers & Protection
/
Residual Current Devices (RCD)
/
RCCB (Residual Current Circuit Breakers)
Filter
RCCB (Residual Current Circuit Breakers)
ABB 2CSF204001R3900 F204 AC-100/0.3 4P 100A RCCB Residual Current Circuit Breaker DIN-Rail
ABB 2CSF204001R1950 F204 AC-125/0.03 4P 125A 30mA 10kA Residual Current Circuit Breaker
ABB 2CSF204001R1900 F204 AC-100/0.03 4P 100A 30mA DIN-Rail Residual Current Circuit Breaker (RCCB)
ABB 2CSF204001R1800 F204 AC-80/0.03 4P 80A DIN-Rail Residual Current Circuit Breaker (RCCB)
ABB 2CSF202001R3900 F202 AC-100/0.3 2P 100A 30mA DIN-Rail Residual Current Circuit Breaker (RCCB)
ABB 2CSF202001R3800 F202 AC-80/0.3 2P 80A 300mA DIN-Rail Residual Current Circuit Breaker (RCCB)
ABB 2CSF202001R1900 F202 AC-100/0.03 2P 100A 30mA Type AC Residual Current Circuit Breaker
ABB 2CSF202001R1800 F202 AC-80/0.03 2P 80A 30mA DIN-Rail Residual Current Circuit Breaker (RCCB)
ABB 2CSF204003R3630 FH204 AC-63/0.3 4P 63A 6kA Residual Current Circuit Breaker
ABB 2CSF204003R3400 FH204 AC-40/0.3 4P 40A 300mA Type AC Residual Current Circuit Breaker
ABB 2CSF204003R3250 FH204 AC-25/0.3 4P 25A 300mA Type AC Residual Current Circuit Breaker
ABB 2CSF204004R1630 FH204 AC-63/0.03 4P 63A 30mA Type AC Residual Current Circuit Breaker
ABB 2CSF204004R1400 FH204 AC-40/0.03 4P 40A 6kA 30mA Residual Current Circuit Breaker
ABB 2CSF204004R1250 FH204 AC-25/0.03 4P 25A 6kA Residual Current Circuit Breaker
ABB 2CSF202003R3630 FH202 AC-63/0.3 2P 63A 6kA DIN Rail Residual Current Circuit Breaker (RCCB)
ABB 2CSF202003R3400 FH202 AC-40/0.3 2P 40A 300mA DIN-Rail Residual Current Circuit Breaker RCCB
ABB 2CSF202003R3250 FH202 AC-25/0.3 2P 25A RCCB Residual Current Circuit Breaker DIN Rail
ABB 2CSF202004R1630 FH202 AC-63/0.03 2P 63A 30mA 6kA Type AC Residual Current Circuit Breaker
ABB 2CSF202004R1400 FH202 AC-40/0.03 2P 40A 30mA DIN-Rail Residual Current Circuit Breaker (RCCB)
ABB 2CSF202004R1250 FH202 AC-25/0.03 2P 25A 6kA 30mA Type AC Residual Current Circuit Breaker
Residual current circuit breakers (RCCB) from ABB, Siemens and Schneider Electric protect people and installations against earth leakage on DIN-rail panels. The range includes F200, FH200, 5SV3, 5SV5, Acti 9 iID and Easy9 Pro in 2-pole, 4-pole and 1+N versions, with sensitivities from 30 mA to 300 mA. Stoklink ships worldwide from Turkey and quotes project volumes.
What's in this range
- ABB F200 and FH200 series in Type AC, A and B, including high-current versions up to 125 A.
- Siemens SENTRON 5SV3 and 5SV5 devices in 2P and 4P, 230 V and 400 V.
- Schneider Electric Acti 9 iID and Easy9 RCCBs.
- Type B devices for drive circuits.
How to choose
- Rated current: at least the total load current of the downstream circuits.
- Sensitivity: 30 mA for personal protection, 300 mA for fire protection or as a selective upstream device.
- Type: AC for resistive loads, A for electronics, B for drives and inverters.
- Short-circuit protection: an RCCB has none. Pair it with an upstream MCB or fuse.
- Poles: 2P for single-phase, 4P for three-phase with neutral.
FAQ
Can an RCCB replace an MCB?
No. An RCCB does not trip on overload or short circuit. It must be protected by an upstream MCB or fuse.
What does Type A mean on an RCCB?
Type A detects sinusoidal AC and pulsating DC residual currents. Type AC detects sinusoidal AC only.
Can I order RCCBs for a project in bulk?
Yes. Request a quote with the part numbers and quantities. Stoklink ships from Turkey, EXW.