Categories
No result found for your search.
Need help? Contact us
+90 542 203 61013
info@stoklink.com
Your cart is empty
- Home
- All Collections
- RCCB (Residual Current Circuit Breakers)
Circuit Breakers & Protection
/
Residual Current Devices (RCD)
/
RCCB (Residual Current Circuit Breakers)
Filter
RCCB (Residual Current Circuit Breakers)
Schneider Electric A9R35440 iID 4P 40A Residual Current Circuit Breaker Acti 9
Schneider Electric A9R34463 iID 4P 63A Residual Current Circuit Breaker Acti9 Series
Schneider Electric A9R14491 iID 4P 100A Residual Current Circuit Breaker Acti 9
Schneider Electric A9R14480 iID 4P 80A Residual Current Circuit Breaker Acti 9
Schneider Electric A9R11491 iID 4P 100A Residual Current Circuit Breaker Acti 9
Schneider Electric A9R11480 iID 4P 80A Residual Current Circuit Breaker Acti 9
ABB 2CSF204001R3400 F204 AC-40/0.3 4P 40A 0.3A DIN-Rail Residual Current Circuit Breaker (RCCB)
ABB 2CSF204001R1400 F204 AC-40/0.03 4P 40A 30mA DIN-Rail Residual Current Circuit Breaker
ABB 2CSF202001R1400 F202 AC-40/0.03 2P 40A 30mA Type AC Residual Current Circuit Breaker
ABB 2CSF202001R1250 F202 AC-25/0.03 2P 25A 30mA DIN-Rail Residual Current Circuit Breaker
ABB 2CSF204001R1250 F204 AC-25/0.03 4P 25A RCCB DIN-Rail Residual Current Circuit Breaker
ABB 2CSF204001R3250 F204 AC-25/0.3 4P 25A Residual Current Circuit Breaker (RCCB) DIN-Rail
ABB 2CSR255080R3254 DS201 C25 AC300 25A 2P 6kA 230V AC Earth Leakage Circuit Breaker
ABB 2CSR255080R3164 DS201 C16 AC300 1P+N 16A 10kA Type AC 300mA Earth Leakage Circuit Breaker RCBO
ABB 2CSR255080R1404 DS201 C40 AC30 1P+N 40A 30mA 10kA Type AC Earth Leakage Circuit Breaker RCBO
ABB 2CSR255080R1204 DS201 C20 AC30 1P+N 20A 10kA Type AC 30mA Earth Leakage Circuit Breaker RCBO
ABB 2CSR255080R1164 DS201 C16 AC30 1P+N 16A 30mA Type AC 6kA Earth Leakage Circuit Breaker RCBO
ABB 2CSR255080R1104 DS201 C10 AC30 1P+N 10A 30mA Type AC 10kA Earth Leakage Circuit Breaker RCBO
ABB 2CSR255080R1064 DS201 C6 AC30 1P+N 6A 30mA 10kA Type AC Earth Leakage Circuit Breaker RCBO
ABB 2CSF204568R3400 F204 B-40/0.3 4P 40A 300mA Type B Residual Current Circuit Breaker
Residual current circuit breakers (RCCB) from ABB, Siemens and Schneider Electric protect people and installations against earth leakage on DIN-rail panels. The range includes F200, FH200, 5SV3, 5SV5, Acti 9 iID and Easy9 Pro in 2-pole, 4-pole and 1+N versions, with sensitivities from 30 mA to 300 mA. Stoklink ships worldwide from Turkey and quotes project volumes.
What's in this range
- ABB F200 and FH200 series in Type AC, A and B, including high-current versions up to 125 A.
- Siemens SENTRON 5SV3 and 5SV5 devices in 2P and 4P, 230 V and 400 V.
- Schneider Electric Acti 9 iID and Easy9 RCCBs.
- Type B devices for drive circuits.
How to choose
- Rated current: at least the total load current of the downstream circuits.
- Sensitivity: 30 mA for personal protection, 300 mA for fire protection or as a selective upstream device.
- Type: AC for resistive loads, A for electronics, B for drives and inverters.
- Short-circuit protection: an RCCB has none. Pair it with an upstream MCB or fuse.
- Poles: 2P for single-phase, 4P for three-phase with neutral.
FAQ
Can an RCCB replace an MCB?
No. An RCCB does not trip on overload or short circuit. It must be protected by an upstream MCB or fuse.
What does Type A mean on an RCCB?
Type A detects sinusoidal AC and pulsating DC residual currents. Type AC detects sinusoidal AC only.
Can I order RCCBs for a project in bulk?
Yes. Request a quote with the part numbers and quantities. Stoklink ships from Turkey, EXW.