Filter

RCCB (Residual Current Circuit Breakers)

Filter
Showing 1 - 100 of 160 items

Schneider Electric EZ9R05425 Easy9 RCCB Residual Current Circuit Breaker

Reference No: EZ9R05425
100 pcs in stock
$44.48

Schneider Electric EZ9R05263 Easy9 RCCB Industrial Electrical Component

Reference No: EZ9R05263
3 pcs in stock
$43.14

Schneider Electric EZ9R05240 Easy9 RCCB 2P 40A 230V Residual Current Device

Reference No: EZ9R05240
Rated Current (A): 40
Rated Voltage (VAC): 230 V
Number of Poles: 2P
100 pcs in stock
$34.65

Schneider Electric EZ9R05225 Easy9 RCCB 2P 25A 230V AC DIN Rail Residual Current Circuit Breaker

Reference No: EZ9R05225
Rated Current (A): 25
Rated Voltage (VAC): 230 V AC
Number of Poles: 2P
100 pcs in stock
$33.30

Schneider Electric A9R61463 iID 4P 63A Residual Current Circuit Breaker Acti 9

Reference No: A9R61463
Rated Current (A): 63
Number of Poles: 4P
100 pcs in stock
$97.49

Schneider Electric A9R61425 iID 4P 25A Residual Current Circuit Breaker Acti 9 Series

Reference No: A9R61425
Rated Current (A): 25
Number of Poles: 4P
67 pcs in stock
$81.04

Schneider Electric A9R61240 iID 2P 40A Residual Current Circuit Breaker (RCCB) Acti 9

Reference No: A9R61240
Rated Current (A): 40
Number of Poles: 2P
100 pcs in stock
$60.35

Schneider Electric A9R61225 iID 2P 25A Residual Current Circuit Breaker (RCCB) Acti 9

Reference No: A9R61225
Rated Current (A): 25
Number of Poles: 2P
100 pcs in stock
$57.90

Schneider Electric A9R44463 iID 4P 63A Residual Current Circuit Breaker (RCCB) Acti9

Reference No: A9R44463
Rated Current (A): 63
Number of Poles: 4P
100 pcs in stock
$65.38

Schneider Electric A9R44440 iID 4P 40A Residual Current Circuit Breaker (RCCB) Acti 9

Reference No: A9R44440
Rated Current (A): 40
Number of Poles: 4P
100 pcs in stock
$57.41

Schneider Electric A9R44425 iID 4P 25A Residual Current Circuit Breaker Acti 9

Reference No: A9R44425
Rated Current (A): 25
Number of Poles: 4P
100 pcs in stock
$55.92

Schneider Electric A9R44263 iID 2P 63A Residual Current Circuit Breaker Acti 9

Reference No: A9R44263
Rated Current (A): 63
Number of Poles: 2P
1 pcs in stock
$49.34

Schneider Electric A9R44240 iID 2P 40A Residual Current Circuit Breaker Acti 9

Reference No: A9R44240
Rated Current (A): 40
Number of Poles: 2P
71 pcs in stock
$41.35

Schneider Electric A9R44225 iID 2P 25A Residual Current Circuit Breaker Acti 9

Reference No: A9R44225
Rated Current (A): 25
Number of Poles: 2P
100 pcs in stock
$39.97

Schneider Electric A9R41463 iID 4P 63A Residual Current Circuit Breaker Acti 9

Reference No: A9R41463
Rated Current (A): 63
Number of Poles: 4P
100 pcs in stock
$71.29

Schneider Electric A9R41440 iID 4P 40A Residual Current Circuit Breaker Acti 9

Reference No: A9R41440
Rated Current (A): 40
Number of Poles: 4P
100 pcs in stock
$60.85

Schneider Electric A9R41263 iID 2P 63A Residual Current Circuit Breaker (RCCB) Acti9

Reference No: A9R41263
Rated Current (A): 63
Number of Poles: 2P
100 pcs in stock
$55.64

Schneider Electric A9R41240 iID 2P 40A Residual Current Circuit Breaker Acti 9

Reference No: A9R41240
Rated Current (A): 40
Number of Poles: 2P
100 pcs in stock
$51.00

Schneider Electric A9R41225 iID 2P 25A Residual Current Circuit Breaker (RCCB) Acti 9

Reference No: A9R41225
Rated Current (A): 25
Number of Poles: 2P
100 pcs in stock
$42.34

Schneider Electric A9R35463 iID 4P 63A Residual Current Circuit Breaker (RCCB) Acti 9

Reference No: A9R35463
Rated Current (A): 63
Number of Poles: 4P
52 pcs in stock
$162.91

Residual current circuit breakers (RCCB) from ABB, Siemens and Schneider Electric protect people and installations against earth leakage on DIN-rail panels. The range includes F200, FH200, 5SV3, 5SV5, Acti 9 iID and Easy9 Pro in 2-pole, 4-pole and 1+N versions, with sensitivities from 30 mA to 300 mA. Stoklink ships worldwide from Turkey and quotes project volumes.

What's in this range

  • ABB F200 and FH200 series in Type AC, A and B, including high-current versions up to 125 A.
  • Siemens SENTRON 5SV3 and 5SV5 devices in 2P and 4P, 230 V and 400 V.
  • Schneider Electric Acti 9 iID and Easy9 RCCBs.
  • Type B devices for drive circuits.

How to choose

  • Rated current: at least the total load current of the downstream circuits.
  • Sensitivity: 30 mA for personal protection, 300 mA for fire protection or as a selective upstream device.
  • Type: AC for resistive loads, A for electronics, B for drives and inverters.
  • Short-circuit protection: an RCCB has none. Pair it with an upstream MCB or fuse.
  • Poles: 2P for single-phase, 4P for three-phase with neutral.

FAQ

Can an RCCB replace an MCB?

No. An RCCB does not trip on overload or short circuit. It must be protected by an upstream MCB or fuse.

What does Type A mean on an RCCB?

Type A detects sinusoidal AC and pulsating DC residual currents. Type AC detects sinusoidal AC only.

Can I order RCCBs for a project in bulk?

Yes. Request a quote with the part numbers and quantities. Stoklink ships from Turkey, EXW.