Categories
No result found for your search.
Need help? Contact us
+90 542 203 61013
info@stoklink.com
Your cart is empty
- Home
- All Collections
- RCCB (Residual Current Circuit Breakers)
Circuit Breakers & Protection
/
Residual Current Devices (RCD)
/
RCCB (Residual Current Circuit Breakers)
Filter
RCCB (Residual Current Circuit Breakers)
Schneider Electric EZ9R05425 Easy9 RCCB Residual Current Circuit Breaker
Schneider Electric EZ9R05263 Easy9 RCCB Industrial Electrical Component
Schneider Electric EZ9R05240 Easy9 RCCB 2P 40A 230V Residual Current Device
Schneider Electric EZ9R05225 Easy9 RCCB 2P 25A 230V AC DIN Rail Residual Current Circuit Breaker
Schneider Electric A9R61463 iID 4P 63A Residual Current Circuit Breaker Acti 9
Schneider Electric A9R61425 iID 4P 25A Residual Current Circuit Breaker Acti 9 Series
Schneider Electric A9R61240 iID 2P 40A Residual Current Circuit Breaker (RCCB) Acti 9
Schneider Electric A9R61225 iID 2P 25A Residual Current Circuit Breaker (RCCB) Acti 9
Schneider Electric A9R44463 iID 4P 63A Residual Current Circuit Breaker (RCCB) Acti9
Schneider Electric A9R44440 iID 4P 40A Residual Current Circuit Breaker (RCCB) Acti 9
Schneider Electric A9R44425 iID 4P 25A Residual Current Circuit Breaker Acti 9
Schneider Electric A9R44263 iID 2P 63A Residual Current Circuit Breaker Acti 9
Schneider Electric A9R44240 iID 2P 40A Residual Current Circuit Breaker Acti 9
Schneider Electric A9R44225 iID 2P 25A Residual Current Circuit Breaker Acti 9
Schneider Electric A9R41463 iID 4P 63A Residual Current Circuit Breaker Acti 9
Schneider Electric A9R41440 iID 4P 40A Residual Current Circuit Breaker Acti 9
Schneider Electric A9R41263 iID 2P 63A Residual Current Circuit Breaker (RCCB) Acti9
Schneider Electric A9R41240 iID 2P 40A Residual Current Circuit Breaker Acti 9
Schneider Electric A9R41225 iID 2P 25A Residual Current Circuit Breaker (RCCB) Acti 9
Schneider Electric A9R35463 iID 4P 63A Residual Current Circuit Breaker (RCCB) Acti 9
Residual current circuit breakers (RCCB) from ABB, Siemens and Schneider Electric protect people and installations against earth leakage on DIN-rail panels. The range includes F200, FH200, 5SV3, 5SV5, Acti 9 iID and Easy9 Pro in 2-pole, 4-pole and 1+N versions, with sensitivities from 30 mA to 300 mA. Stoklink ships worldwide from Turkey and quotes project volumes.
What's in this range
- ABB F200 and FH200 series in Type AC, A and B, including high-current versions up to 125 A.
- Siemens SENTRON 5SV3 and 5SV5 devices in 2P and 4P, 230 V and 400 V.
- Schneider Electric Acti 9 iID and Easy9 RCCBs.
- Type B devices for drive circuits.
How to choose
- Rated current: at least the total load current of the downstream circuits.
- Sensitivity: 30 mA for personal protection, 300 mA for fire protection or as a selective upstream device.
- Type: AC for resistive loads, A for electronics, B for drives and inverters.
- Short-circuit protection: an RCCB has none. Pair it with an upstream MCB or fuse.
- Poles: 2P for single-phase, 4P for three-phase with neutral.
FAQ
Can an RCCB replace an MCB?
No. An RCCB does not trip on overload or short circuit. It must be protected by an upstream MCB or fuse.
What does Type A mean on an RCCB?
Type A detects sinusoidal AC and pulsating DC residual currents. Type AC detects sinusoidal AC only.
Can I order RCCBs for a project in bulk?
Yes. Request a quote with the part numbers and quantities. Stoklink ships from Turkey, EXW.