Categories
No result found for your search.
Need help? Contact us
+90 542 203 61013
info@stoklink.com
Your cart is empty
- Home
- All Collections
- RCCB (Residual Current Circuit Breakers)
Circuit Breakers & Protection
/
Residual Current Devices (RCD)
/
RCCB (Residual Current Circuit Breakers)
Filter
RCCB (Residual Current Circuit Breakers)
Siemens 5SV3314-6 5SV3 40A 2P 230V Residual Current Device
Siemens 5SV3312-6 5SV3 25A 2P 230V Residual Current Device
Siemens 5SV3311-6 5SV3 16A 2P 230V Residual Current Device
Siemens 5SV3111-6 5SV3 16A 2P 230V Residual Current Device
Schneider Electric EZ9R69463 Easy9 Pro 4P 63A Residual Current Circuit Breaker (RCCB)
Schneider Electric EZ9R69440 Easy9 Pro 4P 40A Residual Current Circuit Breaker RCCB
Schneider Electric EZ9R69425 Easy9 Pro RCCB 4P 25A Residual Current Circuit Breaker
Schneider Electric EZ9R69240 Easy9 Pro RCCB 2P 40A Residual Current Circuit Breaker
Schneider Electric EZ9R69225 Easy9 Pro RCCB 2P 25A Residual Current Circuit Breaker
Schneider Electric EZ9R39463 Easy9 Pro RCCB 4P 63A Residual Current Circuit Breaker
Schneider Electric EZ9R39440 Easy9 Pro RCCB 4P 40A Residual Current Circuit Breaker
Schneider Electric EZ9R39425 Easy9 Pro RCCB 4P 25A Residual Current Circuit Breaker
Schneider Electric EZ9R39263 Easy9 Pro RCCB 2P 63A Residual Current Circuit Breaker
Schneider Electric EZ9R39240 Easy9 Pro RCCB 4P Residual Current Circuit Breaker
Schneider Electric EZ9R39225 Easy9 Pro RCCB 2P 25A Residual Current Circuit Breaker
Schneider Electric EZ9R63463 Easy9 RCCB 4P 63A Residual Current Circuit Breaker
Schneider Electric EZ9R63440 Easy9 RCCB 4P 40A 400V Residual Current Circuit Breaker
Schneider Electric EZ9R63240 Easy9 RCCB 2P 40A 230V Residual Current Circuit Breaker
Schneider Electric EZ9R05463 Easy9 RCCB Industrial Electrical Component
Schneider Electric EZ9R05440 Easy9 RCCB 4P 40A 30mA Residual Current Circuit Breaker
Residual current circuit breakers (RCCB) from ABB, Siemens and Schneider Electric protect people and installations against earth leakage on DIN-rail panels. The range includes F200, FH200, 5SV3, 5SV5, Acti 9 iID and Easy9 Pro in 2-pole, 4-pole and 1+N versions, with sensitivities from 30 mA to 300 mA. Stoklink ships worldwide from Turkey and quotes project volumes.
What's in this range
- ABB F200 and FH200 series in Type AC, A and B, including high-current versions up to 125 A.
- Siemens SENTRON 5SV3 and 5SV5 devices in 2P and 4P, 230 V and 400 V.
- Schneider Electric Acti 9 iID and Easy9 RCCBs.
- Type B devices for drive circuits.
How to choose
- Rated current: at least the total load current of the downstream circuits.
- Sensitivity: 30 mA for personal protection, 300 mA for fire protection or as a selective upstream device.
- Type: AC for resistive loads, A for electronics, B for drives and inverters.
- Short-circuit protection: an RCCB has none. Pair it with an upstream MCB or fuse.
- Poles: 2P for single-phase, 4P for three-phase with neutral.
FAQ
Can an RCCB replace an MCB?
No. An RCCB does not trip on overload or short circuit. It must be protected by an upstream MCB or fuse.
What does Type A mean on an RCCB?
Type A detects sinusoidal AC and pulsating DC residual currents. Type AC detects sinusoidal AC only.
Can I order RCCBs for a project in bulk?
Yes. Request a quote with the part numbers and quantities. Stoklink ships from Turkey, EXW.