Filter

Motor Control & Protection Categories

Motor Control & Protection

Filter
Showing 1 - 3000 of 3212 items

ABB 1SAM350000R1002 MS132-0.25 0.16-0.25A 3P 100kA 400VAC Motor Protection Circuit Breaker

Reference No: 1SAM350000R1002
Catalog No: MS132-0.25
Rated Current (A): 0.25
Breaking Capacity (kA): (230 V AC) 100 kA
Rated Voltage (VAC): 400 V AC
Number of Poles: 3P
42 pcs in stock
$38.21

ABB 1SAM250000R1013 MS116-20 20A 3P 10kA Motor Protection Circuit Breaker

Reference No: 1SAM250000R1013
Catalog No: MS116-20
Rated Current (A): 20
Breaking Capacity (kA): (230 V AC) 16 kA
Rated Voltage (VAC): 400 V AC
Number of Poles: 3P
559 pcs in stock
$43.15

ABB 1SAM250000R1003 MS116-0.4 0.25-0.40A 3P 50kA Motor Protection Circuit-Breaker

Reference No: 1SAM250000R1003
Catalog No: MS116-0.4
Rated Current (A): 0.40
Breaking Capacity (kA): (230 V AC) 100 kA
Rated Voltage (VAC): 400 V AC
Number of Poles: 3P
558 pcs in stock
$31.65

ABB 1SAM250000R1009 MS116-6.3 4.0-6.3A 3P 50kA 400VAC Motor Protection Circuit-Breaker

Reference No: 1SAM250000R1009
Catalog No: MS116-6.3
Rated Current (A): 6.3
Breaking Capacity (kA): (230 V AC) 75 kA
Rated Voltage (VAC): 400 V AC
Number of Poles: 3P
1144 pcs in stock
$31.65

ABB 1SAM250000R1010 MS116-10 10A 3P 50kA 400VAC Motor Protection Circuit Breaker

Reference No: 1SAM250000R1010
Catalog No: MS116-10
Rated Current (A): 10
Breaking Capacity (kA): (230 V AC) 75 kA
Rated Voltage (VAC): 400 V AC
Number of Poles: 3P
1905 pcs in stock
$34.01

ABB 1SAM250000R1008 MS116-4.0 2.5-4.0A 3P 50kA 400VAC Motor Protection Circuit-Breaker

Reference No: 1SAM250000R1008
Catalog No: MS116-4.0
Rated Current (A): 4.0
Breaking Capacity (kA): (230 V AC) 75 kA
Rated Voltage (VAC): 400 V AC
Number of Poles: 3P
1928 pcs in stock
$31.65

ABB 1SAM250000R1011 MS116-16 16A 3P 16kA Motor Protection Circuit-Breaker

Reference No: 1SAM250000R1011
Catalog No: MS116-16
Rated Current (A): 16
Breaking Capacity (kA): (230 V AC) 16 kA
Rated Voltage (VAC): 400 V AC
Number of Poles: 3P
936 pcs in stock
$38.42

ABB 1SAM250000R1005 MS116-1.0 0.63-1.0A 3P 50kA 400V Motor Protection Circuit Breaker

Reference No: 1SAM250000R1005
Catalog No: MS116-1.0
Rated Current (A): 1.0
Breaking Capacity (kA): (230 V AC) 100 kA
Rated Voltage (VAC): 400 V AC
Number of Poles: 3P
631 pcs in stock
$31.65

ABB 1SAM250000R1006 MS116-1.6 1.0-1.6A 3P 50kA 400VAC Motor Protection Circuit-Breaker

Reference No: 1SAM250000R1006
Catalog No: MS116-1.6
Rated Current (A): 1.6
Breaking Capacity (kA): (230 V AC) 100 kA
Rated Voltage (VAC): 400 V AC
Number of Poles: 3P
4028 pcs in stock
$31.65

ABB 1SAM250000R1007 MS116-2.5 1.6-2.5A 3P 50kA 400V Motor Protection Circuit-Breaker

Reference No: 1SAM250000R1007
Catalog No: MS116-2.5
Rated Current (A): 2.5
Breaking Capacity (kA): (230 V AC) 75 kA
Rated Voltage (VAC): 400 V AC
Number of Poles: 3P
4768 pcs in stock
$31.65

ABB 1SAM250000R1004 MS116-0.63 0.40-0.63A 3P 50kA Motor Protection Circuit Breaker

Reference No: 1SAM250000R1004
Catalog No: MS116-0.63
Rated Current (A): 0.63
Breaking Capacity (kA): (230 V AC) 100 kA
Rated Voltage (VAC): 400 V AC
Number of Poles: 3P
48 pcs in stock
$31.65

ABB 1SAM250000R1002 MS116-0.25 0.16-0.25A 3P 50kA 400VAC Motor Protection Circuit-Breaker

Reference No: 1SAM250000R1002
Catalog No: MS116-0.25
Rated Current (A): 0.25
Breaking Capacity (kA): (230 V AC) 100 kA
Rated Voltage (VAC): 400 V AC
Number of Poles: 3P
877 pcs in stock
$33.43

ABB 1SAM250000R1001 MS116-0.16 0.10-0.16A 3P 50kA 400VAC Motor Protection Circuit-Breaker

Reference No: 1SAM250000R1001
Catalog No: MS116-0.16
Rated Current (A): 0.16
Breaking Capacity (kA): (230 V AC) 100 kA
Rated Voltage (VAC): 400 V AC
Number of Poles: 3P
179 pcs in stock
$33.43

ABB 1SBN010010R1010 CA5-10 1NO 6A 690V Front Mount Auxiliary Contact Block

Reference No: 1SBN010010R1010
Catalog No: CA5-10
Rated Current (A): 6
Rated Voltage (VAC): 690 V
Number of Poles: 1P
1737 pcs in stock
$9.52

ABB 1SBN010020R1011 CAL5-11 2P 1NO+1NC Side Mount Auxiliary Contact Block 690V

Reference No: 1SBN010020R1011
Catalog No: CAL5-11
Rated Current (A): 6
Rated Voltage (VAC): 690 V
Number of Poles: 2P
469 pcs in stock
$7.33

ABB 1SBN010010R1001 CA5-01 1NO Front Mount Auxiliary Contact Block 6A 690V

Reference No: 1SBN010010R1001
Catalog No: CA5-01
Rated Current (A): 6
Rated Voltage (VAC): 690 V
Number of Poles: 1P
330 pcs in stock
$9.52

ABB 1SBL351024R8000 UA50-30-00RA 220-230V 50Hz/230-240V 60Hz 3-Pole Contactor

Reference No: 1SBL351024R8000
Catalog No: UA50-30-00RA 220-230V 50Hz/230-240V 60Hz
Number of Poles: 3P
183 pcs in stock
$174.93

ABB 1SBL281024R8010 UA30-30-10RA 220-230V 50Hz / 230-240V 60Hz 3-Pole Contactor

Reference No: 1SBL281024R8010
Catalog No: UA30-30-10RA 220-230V 50Hz / 230-240V 60Hz
Number of Poles: 3P
98 pcs in stock
$120.78

ABB 1SBL371024R8000 UA63-30-00RA 220-230V50Hz/230-240V60Hz 3-Pole Contactor

Reference No: 1SBL371024R8000
Catalog No: UA63-30-00RA 220-230V50Hz/230-240V60Hz
Number of Poles: 3P
160 pcs in stock
$200.66

ABB 1SFL447101R1111 AF140-40-11-11 4-Pole 200A 690V AC-1 75kW AC Switching Power Contactor

Reference No: 1SFL447101R1111
Catalog No: AF140-40-11-11
Rated Current (A): 200
Rated Voltage (VAC): 690 V AC
Number of Poles: 4P
1 pcs in stock
$448.40

Motor control and protection equipment from ABB, Siemens and Schneider Electric covers everything between the supply and the motor shaft. The range spans contactors, overload relays, motor protection circuit breakers, starters, soft starters, variable frequency drives, servo systems and industrial motors, with rated currents from 0.1 A to 2,650 A and power up to 800 kW. Stoklink ships worldwide from Turkey and quotes project volumes on request.

What's in this range

How to choose

  • Motor power and rated current at the supply voltage. Size the starter or drive for the nameplate current, not just the kW value.
  • Starting method: direct on line, soft start or variable speed. This decides whether you need a contactor, a soft starter or a VFD.
  • Duty class, for example AC-3 for squirrel-cage motors under IEC 60947-4-1.
  • Protection split: overload relay plus fuses or MCB, or a single MPCB.
  • Control interface: coil voltage, fieldbus such as PROFINET, and mounting.

FAQ

What is the difference between a soft starter and a VFD?

A soft starter limits inrush current during start and stop at fixed supply frequency. A VFD changes the output frequency, so it also controls speed while running.

Do I need a contactor and an overload relay, or an MPCB?

An MPCB combines short-circuit and overload protection and works with a contactor. The separate route uses a fuse or MCB, a contactor and an overload relay. Choose by space, coordination type and rating.

Can you ship motor control products outside Turkey?

Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, and project quantities are quoted on request.