The ABB CAL5-11 auxiliary contact block (SKU: 1SBN010020R1011) is a 2-pole, 1NO+1NC side-mounted auxiliary contact module designed for use with ABB contactors in industrial control and automation applications. Rated up to 690V AC, the CAL5-11 provides reliable signal and control circuit switching with compact 12 mm width, making it ideal for space-constrained control panel installations.
| Product Net Width | 12 mm |
|---|---|
| Product Net Depth / Length | 62 mm |
| Product Net Height | 74 mm |
| Product Net Weight | 0.05 kg |
| Number of Auxiliary Contacts NO | 1 |
|---|---|
| Number of Auxiliary Contacts NC | 1 |
| Number of Poles | 2P |
| Rated Operational Voltage | Auxiliary Circuit 690 V |
| Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz |
| Rated Operational Current AC-15 (Ie) | (500 V) 2 A, (690 V) 2 A, (24 / 127 V) 6 A, (220 / 240 V) 4 A, (380 / 400 V) 3 A |
| Rated Operational Current DC-13 (Ie) | (24 V) 6 A / 144 W, (48 V) 2.8 A / 134 W, (72 V) 1 A / 72 W, (110 V) 0.55 A / 60 W, (125 V) 0.55 A / 69 W, (220 V) 0.30 A / 66 W, (250 V) 0.3 / 75 W |
| Short-Circuit Protective Devices | Auxiliary Circuit - gG Type Fuses 10 A |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 0.1 s 140 A, for 1 s 100 A |
| Rated Insulation Voltage (Ui) | acc. to IEC 60947-5-1 690 V, acc. to UL/CSA 600 V |
| Maximum Electrical Switching Frequency | 1200 cycles per hour |
| Mechanical Durability | 10 million, 3 million, 2 million |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Minimum Switching Capacity | A9 ... A75 17 / 5 VLT4K, A95 ... AF750 24 / 50 VLT4K |
| Power Loss | at Rated Operating Conditions per Pole 0.1 W |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 |
| Terminal Type | Screw Terminals |
| Suitable For | AF45, AF50, AF63, AF75, A9, A12, A16, A26, A30, A40, A45, A50, A63, A75, A95, A110, AL9, AL12, AL16, AL26, AL30, AL40, AE45, AE50, AE63, AE75, TAL9, TAL12, TAL16, TAL26, TAL30, TAL40, TAE45, TAE50, TAE75, GA75, GAE75, UA16, UA26, UA30, UA50, UA63, UA75, UA16RA, UA26RA, UA30RA, UA50RA, UA63RA, UA75RA, UAF75RA, N22E, N31E, N40E, N44E, N53E, N62E, N71E, N80E, N33/11, N51/11, NL22E, NL31E, NL40E |
| Product Name | Auxiliary Contact Block |
| Remarks | 100 |
| REACH Declaration | 2CMT2021-006202 |
|---|---|
| RoHS Declaration | 2CMT2021-006277 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act - TSCA | 2CMT2023-006525 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| Part number | 1SBN010020R1011 |
|---|---|
| Type designation | CAL5-11 |
| Brand | ABB |
| Condition | New, factory sealed |
| Source | ABB and its authorised distributors |
| Warranty | Manufacturer warranty |
| EAN | 3471522121073 |
| eCl@ss | 27371302 |
| Minimum Order Quantity | 2 piece |
| Customs Tariff Number | 85389099 |
| ETIM 7 | EC000041 - Auxiliary contact block |
|---|---|
| eClass | V11.0 : 27371302 |
| UNSPSC | 39121522 |
| Package Level 1 Units | box 2 piece |
|---|---|
| Package Level 1 Width | 100 mm |
| Package Level 1 Depth / Length | 105.5 mm |
| Package Level 1 Height | 35 mm |
| Package Level 1 Gross Weight | 0.1 kg |
| Package Level 1 EAN | 3471522121073 |
| Shipping weight | 0.1 kg |
| Ships from | Türkiye |
| Dispatch | 17 Nov |
| Stock | In stock |
Source: manufacturer data · Last verified: 30 Oct 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated current of CAL5-11 is 6 A.
The rated operational voltage of CAL5-11 is 690 V AC.
The tariff (HS) code on file for CAL5-11 is 85389099.
The EAN (GTIN) of CAL5-11 is 3471522121073.
CAL5-11 ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival. Stock items are dispatched within 1–2 business days.
AC-1 and AC-6a contactors for data center PDU and UPS systems: sizing, harmonic derating, coil selection, and endurance guidance for engineers. Shop at Stoklink.
Compare AC3 rating IEC contactors versus NEMA size codes, with cross-reference tables, derating formulas, and selection tips for engineers. Shop at Stoklink.
Master AC3 rating selection with our complete contactor checklist covering load sizing, utilization categories, derating, and coordination. Shop at Stoklink.