- Home
- All Collections
- Motor Control & Protection
Motor Control & Protection
Motor Control & Protection Categories
Motor Control & Protection
ABB 1SAX351001R1101 EF146-150 Electronic Overload Relay 54-150A 3P 160x107x97mm
ABB 1SAX721001R1101 EF460-500 150-500A 3P Electronic Overload Relay
ABB 1SAX611001R1101 EF370-380 Electronic Overload Relay 115...380A 3P
ABB 1SAX531001R1101 EF205-210 63-210A 3P Electronic Overload Relay
ABB 1SAX821001R1101 EF750-800 Electronic Overload Relay 250-800A 3P 144x270x250mm
ABB 1SAZ421201R1005 TA200DU-175 130-175A 3P Thermal Overload Relay
ABB 1SAX121001R1103 EF19-2.7 Electronic Overload Relay 0.80-2.7A 3P
ABB 1SAZ421201R1004 TA200DU-150 Thermal Overload Relay 110...150A 3P
ABB 1SAX121001R1101 EF19-0.32 0.10-0.32A 3P Electronic Overload Relay
ABB 1SAX121001R1104 EF19-6.3 Electronic Overload Relay 1.9-6.3A 3P
ABB 1SAZ421201R1003 TA200DU-135 Thermal Overload Relay 100-135A 3P
ABB 1SAZ421201R1002 TA200DU-110 Thermal Overload Relay 80-110A 3P
ABB 1SAX121001R1105 EF19-18.9 Electronic Overload Relay 5.7-18.9A 3P
ABB 1SAZ421201R1006 TA200DU-200 Thermal Overload Relay 150...200A 3P
ABB 1SAZ431201R1002 TF140DU-110 Thermal Overload Relay 80...110A 3P
ABB 1SAZ431201R1001 TF140DU-90 Thermal Overload Relay 66-90A 3P
ABB 1SAZ911201R1003 TF96-68 57...68A 3P Thermal Overload Relay
ABB 1SAZ911201R1005 TF96-87 75-87A 3P Thermal Overload Relay
ABB 1SAZ431201R1003 TF140DU-135 Thermal Overload Relay 100-135A 3P
ABB 1SAZ421201R1001 TA200DU-90 Thermal Overload Relay 66-90A 3P
Motor control and protection equipment from ABB, Siemens and Schneider Electric covers everything between the supply and the motor shaft. The range spans contactors, overload relays, motor protection circuit breakers, starters, soft starters, variable frequency drives, servo systems and industrial motors, with rated currents from 0.1 A to 2,650 A and power up to 800 kW. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- Contactors – switching devices for motor and load circuits, mostly 3-pole
- Thermal Overload Relays – bimetal and electronic relays for motor overload protection
- Motor Protection Circuit Breakers (MPCB) – short-circuit and overload protection in one device
- Motor Starters & Motor Management – starter combinations and motor controllers such as TeSys U and SIRIUS 3RK
- Soft Starters – controlled ramp-up for 3-phase motors
- Variable Frequency Drives (VFD) – speed control with ABB ACS, Schneider Altivar and Siemens SINAMICS
- Servo Drives & Motion Control – servo motors, drives, controllers and cables
- Industrial Motors – SIMOTICS asynchronous motors
How to choose
- Motor power and rated current at the supply voltage. Size the starter or drive for the nameplate current, not just the kW value.
- Starting method: direct on line, soft start or variable speed. This decides whether you need a contactor, a soft starter or a VFD.
- Duty class, for example AC-3 for squirrel-cage motors under IEC 60947-4-1.
- Protection split: overload relay plus fuses or MCB, or a single MPCB.
- Control interface: coil voltage, fieldbus such as PROFINET, and mounting.
FAQ
What is the difference between a soft starter and a VFD?
A soft starter limits inrush current during start and stop at fixed supply frequency. A VFD changes the output frequency, so it also controls speed while running.
Do I need a contactor and an overload relay, or an MPCB?
An MPCB combines short-circuit and overload protection and works with a contactor. The separate route uses a fuse or MCB, a contactor and an overload relay. Choose by space, coordination type and rating.
Can you ship motor control products outside Turkey?
Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, and project quantities are quoted on request.