- Description
The ABB 1SDA068329R1 is a Tmax XT4S 250 moulded case circuit breaker fitted with a TMA thermomagnetic release, rated In 200 A inside the 250 A frame. Built for four-pole, fixed, front-terminal installation, it carries a 50 kA breaking capacity at 415 V AC with adjustable thermal (140-200 A) and magnetic (1000-2000 A) trip settings for close coordination with downstream protection.
Technical Specifications
| SKU | 1SDA068329R1 |
| Brand | ABB |
| Series | Tmax XT |
| Catalog Designation | XT4S 250 TMA 200-2000 4p F F InN=100% |
| EAN | 8015644696375 |
| Sub-type | XT4 |
| Number of Poles | 4P |
| Rated Current (In) | 200 A |
| Rated Uninterrupted Current (Iu) | 250 A |
| Thermal Setting Range | 140-200 A |
| Magnetic Trip Setting (Ii) | 1000-2000 A |
| Release | TMA (thermomagnetic, type TM) |
| Short-Circuit Performance Level | S |
| Current Type | AC/DC |
| Rated Operational Voltage (Ue) | 690 V AC / 750 V DC |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Ultimate Breaking Capacity (Icu) | 85 kA at 220-240 V AC, 50 kA at 380-440 V AC, 36 kA at 500 V AC, 25 kA at 525 V AC, 12 kA at 690 V AC; 50 kA at 250-500 V DC |
| Rated Service Breaking Capacity (Ics) | equal to Icu at all listed voltages |
| Connecting Capacity, Main Circuit | Busbar 85-200 mm² |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Power Loss | 11.88 W per pole |
| Rated Frequency | 50/60 Hz |
| Dimensions (W x H x D) | 140 x 160 x 82.5 mm |
| Net Weight | 3.5 kg |
Certifications & Standards
- IEC/EN 60947-2
Selection Notes
The TMA thermomagnetic release on the 1SDA068329R1 is factory-set at 200 A inside the 250 A XT4S frame, so the 140-200 A thermal band and 1000-2000 A instantaneous trip can be dialed in without changing the breaker body if the protected load grows. Short-circuit performance class S pairs an equal 50 kA ultimate (Icu) and service (Ics) rating at 415 V AC, meaning the breaker stays serviceable after clearing a fault at its full rated capacity rather than only surviving a single interruption. Four-pole, fixed, front-terminal construction with 100% rated neutral (InN=100%) suits direct panel mounting on three-phase-plus-neutral distribution where the frame's higher 250 A busbar rating leaves headroom for a larger release later.