Filter

Automatic Transfer Switches (ATS)

Filter
Showing 1 - 154 of 154 items

Schneider Electric TR63D3R5004TPE TransferPacT Remotely Operated 3P 500 A 400 V Automatic Transfer Switch

Reference No: TR63D3R5004TPE
Catalog No: TR63D3R5004TPE
Rated Current (A): 500
Rated Voltage (VAC): 400 V AC
0 pcs in stock
$2,488.26

Schneider Electric TPSISO65 TransferPacT Interphase Barrier for Frame 250-630 A Transfer Switch Accessory

Reference No: TPSISO65
Catalog No: TPSISO65
0 pcs in stock
$86.15

Schneider Electric TR63D3R4004TPE TransferPacT Remotely Operated 3P 400 A 400 V Automatic Transfer Switch

Reference No: TR63D3R4004TPE
Catalog No: TR63D3R4004TPE
Rated Current (A): 400
Rated Voltage (VAC): 400 V AC
0 pcs in stock
$2,404.77

Schneider Electric TPSISO42 TransferPacT Long Terminal Shield for Frame 630 A Transfer Switch Accessory

Reference No: TPSISO42
Catalog No: TPSISO42
0 pcs in stock
$45.86

Schneider Electric TR63D3R3204TPE TransferPacT Remotely Operated 3P 320 A 400 V Automatic Transfer Switch

Reference No: TR63D3R3204TPE
Catalog No: TR63D3R3204TPE
Rated Current (A): 320
Rated Voltage (VAC): 400 V AC
0 pcs in stock
$2,404.77

Schneider Electric TPSISO31 TransferPacT Terminal Shield for Frame 160 A Transfer Switch Accessory

Reference No: TPSISO31
Catalog No: TPSISO31
0 pcs in stock
$38.02

Schneider Electric TR25D4R2504TPE TransferPacT Remotely Operated 4P 250 A 400 V Automatic Transfer Switch

Reference No: TR25D4R2504TPE
Catalog No: TR25D4R2504TPE
Rated Current (A): 250
Rated Voltage (VAC): 400 V AC
0 pcs in stock
$1,647.66

Schneider Electric TPSISO30 TransferPacT Terminal Shield for Frame 100 A Transfer Switch Accessory

Reference No: TPSISO30
Catalog No: TPSISO30
0 pcs in stock
$38.02

ABB 1SCA153430R1001 OXB200E3S3QT 4P 200-480VAC Open Style TruONE Automatic Transfer Switch

Reference No: 1SCA153430R1001
Catalog No: OXB200E3S3QT
Rated Voltage (VAC): 200/480 V AC
Number of Poles: 4P
2 pcs in stock
$2,849.37

ABB 1SCA150935R1001 OXB800E3S2QT TruONE 800A 3-Pole 200-480VAC Open Style Automatic Transfer Switch

Reference No: 1SCA150935R1001
Catalog No: OXB800E3S2QT
Rated Current (A): 800
Rated Voltage (VAC): 200/480 V AC
Number of Poles: 3P
0 pcs in stock
$4,453.24

ABB 1SCA153623R1001 OXB1600E3S2QT 1600A 3-Pole 200-480VAC Open Style TruONE Automatic Transfer Switch

Reference No: 1SCA153623R1001
Catalog No: OXB1600E3S2QT
Rated Current (A): 1600
Rated Voltage (VAC): 200/480 V AC
Number of Poles: 3P
1 pcs in stock
$6,745.96

ABB 1SCA153457R1001 OXB250E3S2QT TruONE 4P 200-480VAC Open Style Automatic Transfer Switch

Reference No: 1SCA153457R1001
Catalog No: OXB250E3S2QT
Rated Voltage (VAC): 200/480 V AC
Number of Poles: 4P
1 pcs in stock
$2,225.78

ABB 1SDA065524R1 ATS022 AUTO.TRAN.SWITCH ADVANCED CONTROL Automatic Transfer Switch

Reference No: 1SDA065524R1
Catalog No: ATS022 AUTO.TRAN.SWITCH ADVANCED CONTROL
13 pcs in stock
$1,198.74

ABB 1SDA065523R1 ATS021 Automatic Transfer Switch Mutli Voltage Automatic Transfer Switch

Reference No: 1SDA065523R1
Catalog No: ATS021 Automatic Transfer Switch Mutli Voltage
16 pcs in stock
$998.32

Automatic transfer switches (ATS) from ABB and Schneider Electric, rated from 32 A up to 1600 A in 2P to 4P versions. Stoklink lists over 280 items, including Schneider Electric TransferPacT and TruONE and ABB OXB and OTM units. We ship worldwide from Turkey and quote project volumes on request.

What's in this range

  • Schneider Electric TransferPacT in rotary controller and remotely operated versions.
  • Schneider Electric TruONE and Compact ATS units.
  • ABB OXB automatic transfer switches with Level 2 (DIP) and Level 3 (LCD) controllers.
  • ABB OTM open transition units for motorized transfer.
  • ATS Accessories – auxiliary contacts, I/O modules, control units and terminal shrouds.

How to choose

  • Rated current. Size for the full load on the emergency bus.
  • Poles. Select 4P when the neutral must be switched.
  • Controller level. Basic DIP-setting controllers suit simple mains-generator duty. LCD controllers add settings and display.
  • Transition type. Open transition breaks before make. Check the load can tolerate the gap.
  • Voltage and short-circuit rating. Match to the system and fault level.

FAQ

Can an ATS start a generator?

Most ATS controllers provide a start signal contact for the generator. Confirm the controller model and its contact rating on the datasheet.

What does open transition mean?

The switch disconnects from the first source before connecting to the second. There is a short break in supply, but the two sources are never paralleled.

Do you ship outside Turkey?

Yes. Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, and we quote project quantities on request.