- Home
- All Collections
- Switch Disconnectors & Transfer Switches
Switch Disconnectors & Transfer Switches
Switch Disconnectors & Transfer Switches Categories
Switch Disconnectors & Transfer Switches
Schneider Electric C125S4NAFM ComPacT NS1250 NA 4P 1250 A Fixed Manually Operated Switch Disconnector
Schneider Electric C125S3NAFM ComPacT NS1250 NA 3P 1250 A Fixed Manually Operated Switch Disconnector
Schneider Electric E100S4NAFM EasyPact CVS1000NA 4P 1000 A 440 V AC Switch Disconnector
Schneider Electric E100S3NAFM EasyPact CVS1000NA 3P 1000 A 440 V AC Switch Disconnector
Schneider Electric E160S4NAFM EasyPact CVS1600NA 4P 1600 A 440 V AC Switch Disconnector
Schneider Electric E160S3NAFM EasyPact CVS1600NA 3P 1600 A 440 V AC Switch Disconnector
Schneider Electric E080S4NAFM EasyPact CVS800NA 4P 800 A 440 V AC Switch Disconnector
Schneider Electric E125S4NAFM EasyPact CVS1250NA 4P 1250 A 440 V AC Switch Disconnector
Schneider Electric C063S4NAFM ComPacT NS630bNA 4P 630 A Fixed Switch Disconnector
Schneider Electric C063S3NAFM ComPacT NS630bNA 3P 630 A Fixed Switch Disconnector
Schneider Electric C100S4NAFM ComPacT NS1000 NA 4P 1000 A Fixed Manual Switch Disconnector
Schneider Electric C100S3NAFM ComPacT NS1000 NA 3P 1000 A Fixed Manual Switch Disconnector
Schneider Electric C080S4NAFM ComPacT NS800 NA 4P 800 A Fixed Manual Switch Disconnector
Schneider Electric C080S3NAFM ComPacT NS800 NA 3P 800 A Fixed Manual Switch Disconnector
Siemens 3KC9501-1 3KC9 Changeover Switch
Siemens 3KC9401-1 3KC9 Changeover Switch
Siemens 3KC9301-1 3KC9 Changeover Switch
Siemens 3KC9201-3 3KC9 Changeover Switch
Siemens 3KC9000-8TL40 3KC9 240V Changeover Switch
Siemens 3KC9000-8EL62 3KC9 Changeover Switch
Switch disconnectors and transfer switches from ABB, Siemens, Schneider Electric and Mersen, covering isolation, manual changeover, automatic transfer and cam switching from 6 A up to 3800 A. The range includes 1P to 4P devices, with 3P and 4P the most common. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- Switch Disconnectors – load-break isolators for panels and machines, including handles, shafts and interlocks.
- Changeover Switches (Manual & Motorized) – select between two supplies, such as mains and generator.
- Automatic Transfer Switches (ATS) – controller-driven transfer, including TransferPacT and ABB OXB and OTM units.
- Cam Switches – Harmony K rotary switches for control, metering and small loads.
How to choose
- Rated current and utilization category. Match the AC-22 or AC-23 duty to the load, and size for the full load current.
- Pole count. Use 4P where the neutral must be switched, for example when changing between two sources.
- Voltage and short-circuit withstand. Check the rating against the fault level at the installation point.
- Control method. Manual operation suits most panels. Choose motorized or automatic transfer when the change must happen without an operator.
- Mounting. Pick DIN-rail, base, door-coupled or enclosed to fit the panel layout.
FAQ
What is the difference between a switch disconnector and a circuit breaker?
A switch disconnector isolates and switches load current but gives no overcurrent protection. A circuit breaker also trips on overload and short circuit, so a protective device is normally installed upstream of the switch.
When should I use an ATS instead of a manual changeover switch?
Use an ATS when the transfer must happen automatically after a mains failure, for example to a generator. A manual changeover switch needs an operator and suits sites where short outages are acceptable.
Do you ship outside Turkey?
Yes. Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, and we quote project quantities on request.