- Home
- All Collections
- Motor Protection Circuit Breakers (MPCB)
Motor Protection Circuit Breakers (MPCB)
ABB 1SAM360000R1013 MO132-20 Manual Motor Starter Magnetic Only 20A 400V AC 100kA 3P Motor Protection Circuit-Breaker
ABB 1SAM360000R1008 MO132-4.0 4A 3P 100kA Motor Protection Circuit Breaker Magnetic Only
ABB 1SAM360000R1003 MO132-0.4 0.4A 3P 100kA Motor Protection Circuit-Breaker
ABB 1SAM360000R1005 MO132-1.0 1A 3P 100kA Motor Protection Circuit Breaker
ABB 1SAM360000R1011 MO132-16 Manual Motor Starter Magnetic Only 16A 400V AC 100kA 3P Motor Protection Circuit-Breaker
ABB 1SAM360000R1006 MO132-1.6 1.6A 3P 100kA Motor Protection Circuit-Breaker
ABB 1SAM360000R1012 MO132-12 Manual Motor Starter Magnetic Only 12A 400V AC 3P 100kA Motor Protection Circuit Breaker
ABB 1SAM360000R1007 MO132-2.5 2.5A 3P 100kA 400V Motor Protection Circuit-Breaker
ABB 1SAM360000R1010 MO132-10 Manual Motor Starter Magnetic Only 10A 3P 400V AC Motor Protection Circuit Breaker
ABB 1SAM360000R1009 MO132-6.3 Manual Motor Starter Magnetic Only 6.3A 400V AC 100kA 3P Motor Protection Circuit-Breaker
ABB 1SAM360000R1004 MO132-0.63 0.63A 3P 100kA Motor Protection Circuit Breaker
ABB 1SAM350000R1008 MS132-4.0 3P 4A 100kA Motor Protection Circuit Breaker
ABB 1SAM350000R1015 MS132-32 32A 3P 30kA Motor Protection Circuit Breaker
ABB 1SAM350000R1010 MS132-10 6.3-10A 3P 100kA 400VAC Motor Protection Circuit Breaker
ABB 1SAM350000R1014 MS132-25 25A 3P 50kA Motor Protection Circuit-Breaker
ABB 1SAM350000R1012 MS132-12 8-12A 3P 100kA Motor Protection Circuit Breaker
ABB 1SAM360000R1002 MO132-0.25 0.25A 3P 100kA Motor Protection Circuit-Breaker Magnetic Only
ABB 1SAM360000R1001 MO132-0.16 0.16A 3P 100kA 400V Motor Protection Circuit-Breaker Magnetic Only
ABB 1SAM350000R1009 MS132-6.3 4.0-6.3A 3P 100kA 400VAC Motor Protection Circuit-Breaker
ABB 1SAM350000R1011 MS132-16 16A 3P 100kA Motor Protection Circuit Breaker
Motor protection circuit breakers (MPCB) from ABB, Siemens and Schneider Electric combine short-circuit and overload protection for motor feeders. The range covers 0.16 A to 500 A in 3-pole versions, from small manual starters to large thermal-magnetic breakers. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- Siemens SIRIUS 3RV2 and 3RV1 breakers, plus 3RN2 versions for motor protection with thermistor evaluation.
- Schneider Electric TeSys Deca GV2 and GV3 manual starters, TeSys GV4 thermal-magnetic breakers and Easy TeSys Power.
- ABB MS116, MS132 and MS165 manual motor starters and MO132 magnetic-only breakers.
- Accessories such as auxiliary contacts, busbar adapters and trip indicators for the 3RV1935 and GV2 families.
How to choose
- Setting range. The motor full-load current should sit inside the adjustable thermal band.
- Breaking capacity at the supply voltage, in kA, against the prospective short-circuit current.
- Thermal-magnetic or magnetic-only. Magnetic-only breakers need a separate overload relay.
- Coordination with the contactor, type 1 or type 2 under IEC 60947-4-1.
- Frame size and mounting: DIN rail or busbar system.
FAQ
What is the difference between an MPCB and an MCCB?
An MPCB is built around motor starting currents, with an adjustable thermal band and a magnetic trip set for inrush. An MCCB is a general feeder breaker with a wider rating scale.
Does an MPCB replace the overload relay?
Yes, when it has a thermal release. Magnetic-only types such as the ABB MO132 do not, so they need an overload relay downstream.
Do you export MPCBs outside Turkey?
Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, and project quantities are quoted on request.