- Home
- All Collections
- Motor Control & Protection
Motor Control & Protection
Motor Control & Protection Categories
Motor Control & Protection
Siemens 6SL3260-2MA00-0VA0 SINAMICS V90 I/O Connector PROFINET 20-pole VFD Accessory
Siemens 6SL3210-5FE17-0UF0 SINAMICS V90 PN 400V 7.0kW Servo Drive
Siemens 6SL3210-5FE17-0UA0 SINAMICS V90 380-480V 7.0kW Size C Servo Drive
Siemens 6SL3210-5FE15-0UF0 SINAMICS V90 PN 5.0kW 400V PROFINET Servo Drive
Siemens 6SL3210-5FE15-0UA0 SINAMICS V90 380-480V 5.0kW Servo Drive
Siemens 6SL3210-5FE13-5UF0 SINAMICS V90 PROFINET 400V 3.5kW Servo Drive
Siemens 6SL3210-5FE13-5UA0 SINAMICS V90 3.5kW 380-480V 33A Servo Drive
Siemens 6SL3210-5FE12-0UF0 SINAMICS V90 PROFINET 2.0/2.5kW Servo Drive
Siemens 6SL3210-5FE12-0UA0 SINAMICS V90 2.5kW 400V Servo Drive IP20 Size B
Siemens 6SL3210-5FE11-5UF0 SINAMICS V90 PROFINET 1.5/1.75kW 400V Servo Drive
Siemens 6SL3210-5FE11-5UA0 SINAMICS V90 1.5kW 380-480V 15.9A Servo Drive
Siemens 6SL3210-5FE11-0UA0 SINAMICS V90 380-480V 1.0kW Size A Servo Drive
Siemens 6SL3210-5FE10-8UF0 SINAMICS V90 PROFINET 0.75kW Servo Drive
Siemens 6SL3210-5FE10-8UA0 SINAMICS V90 0.75kW 3 AC 400V Servo Drive
Siemens 6SL3210-5FE10-4UF0 SINAMICS V90 PN 0.4kW 380-480V PROFINET Servo Drive
Siemens 6SL3210-5FE10-4UA0 SINAMICS V90 400V 0.4kW 1.2A Servo Drive
Siemens 6SL3210-5FB10-8UA0 SINAMICS V90 1/3 AC 200V 0.75kW Servo Drive
Siemens 6SL3210-5FB10-4UA1 SINAMICS V90 0.4kW 200-240V 1/3AC Servo Drive
Siemens 6SL3210-5FB10-2UA2 SINAMICS V90 200-240V 0.2kW Servo Drive
Siemens 6SL3210-5FB10-1UF2 SINAMICS V90 PROFINET 200V 0.1kW Servo Drive
Motor control and protection equipment from ABB, Siemens and Schneider Electric covers everything between the supply and the motor shaft. The range spans contactors, overload relays, motor protection circuit breakers, starters, soft starters, variable frequency drives, servo systems and industrial motors, with rated currents from 0.1 A to 2,650 A and power up to 800 kW. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- Contactors – switching devices for motor and load circuits, mostly 3-pole
- Thermal Overload Relays – bimetal and electronic relays for motor overload protection
- Motor Protection Circuit Breakers (MPCB) – short-circuit and overload protection in one device
- Motor Starters & Motor Management – starter combinations and motor controllers such as TeSys U and SIRIUS 3RK
- Soft Starters – controlled ramp-up for 3-phase motors
- Variable Frequency Drives (VFD) – speed control with ABB ACS, Schneider Altivar and Siemens SINAMICS
- Servo Drives & Motion Control – servo motors, drives, controllers and cables
- Industrial Motors – SIMOTICS asynchronous motors
How to choose
- Motor power and rated current at the supply voltage. Size the starter or drive for the nameplate current, not just the kW value.
- Starting method: direct on line, soft start or variable speed. This decides whether you need a contactor, a soft starter or a VFD.
- Duty class, for example AC-3 for squirrel-cage motors under IEC 60947-4-1.
- Protection split: overload relay plus fuses or MCB, or a single MPCB.
- Control interface: coil voltage, fieldbus such as PROFINET, and mounting.
FAQ
What is the difference between a soft starter and a VFD?
A soft starter limits inrush current during start and stop at fixed supply frequency. A VFD changes the output frequency, so it also controls speed while running.
Do I need a contactor and an overload relay, or an MPCB?
An MPCB combines short-circuit and overload protection and works with a contactor. The separate route uses a fuse or MCB, a contactor and an overload relay. Choose by space, coordination type and rating.
Can you ship motor control products outside Turkey?
Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, and project quantities are quoted on request.