- Home
- All Collections
- Motor Control & Protection
Motor Control & Protection
Motor Control & Protection Categories
Motor Control & Protection
Schneider Electric LC1E40004M7 Easy TeSys Contactor 4P 4NO AC-1 60 A 220 V AC Coil Contactor
Schneider Electric LC1E3810M5 EasyPact TVS 3P 38A 440V AC Contactor
Schneider Electric LC1E3810B5 Easy TeSys 3-Pole 38A 440V AC Contactor
Schneider Electric LC1E3801M5 Easy TeSys 3-Pole 38A 440V AC Contactor
Schneider Electric LC1E3801BD Easy TeSys Control LC1E 38A 3P 400V 18.5kW Contactor
Schneider Electric LC1E38004M7 Easy TeSys Contactor 4P 4NO AC-1 50 A 220 V AC Coil Contactor
Schneider Electric LC1E3210M5 Easy TeSys 3-Pole 32A 440V AC Contactor
Schneider Electric LC1E3210BD Easy TeSys Control LC1E 32A 3P 400V 15kW Contactor
Schneider Electric LC1E3210B5 Easy TeSys Contactor 3P 3NO AC-3 32 A 15 kW 24 V AC Coil Contactor
Schneider Electric LC1E3201M5 EasyPact TVS 32A 3P 440V AC Contactor
Schneider Electric LC1E300M5 EasyPact TVS 3-Pole 300A AC Contactor
Schneider Electric LC1E2510M5 TeSys E 3-Pole 25A 440V AC Contactor
Schneider Electric LC1E2510BD Easy TeSys Control LC1E 3P 25A 24VDC Contactor
Schneider Electric LC1E2510B5 TeSys E 3-Pole 25A 440V AC Contactor
Schneider Electric LC1E250M5 Easy TeSys 3-Pole 250A 440V AC Power Contactor
Schneider Electric LC1E250B5 Easy TeSys Contactor 3P 3NO AC-3 250 A 140 kW 24 V AC Coil Contactor
Schneider Electric LC1E2501M5 EasyPact TVS 3-Pole 25A 440V AC Contactor
Schneider Electric LC1E2501B5 Easy TeSys Contactor 3P 3NO AC-3 25 A 11 kW 24 V AC Coil Contactor
Schneider Electric LC1E25004M7 Easy TeSys Contactor 4P 4NO AC-1 40 A 220 V AC Coil Contactor
Schneider Electric LC1E200M5 EasyPact TVS 3P 200A 440V AC Contactor
Motor control and protection equipment from ABB, Siemens and Schneider Electric covers everything between the supply and the motor shaft. The range spans contactors, overload relays, motor protection circuit breakers, starters, soft starters, variable frequency drives, servo systems and industrial motors, with rated currents from 0.1 A to 2,650 A and power up to 800 kW. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- Contactors – switching devices for motor and load circuits, mostly 3-pole
- Thermal Overload Relays – bimetal and electronic relays for motor overload protection
- Motor Protection Circuit Breakers (MPCB) – short-circuit and overload protection in one device
- Motor Starters & Motor Management – starter combinations and motor controllers such as TeSys U and SIRIUS 3RK
- Soft Starters – controlled ramp-up for 3-phase motors
- Variable Frequency Drives (VFD) – speed control with ABB ACS, Schneider Altivar and Siemens SINAMICS
- Servo Drives & Motion Control – servo motors, drives, controllers and cables
- Industrial Motors – SIMOTICS asynchronous motors
How to choose
- Motor power and rated current at the supply voltage. Size the starter or drive for the nameplate current, not just the kW value.
- Starting method: direct on line, soft start or variable speed. This decides whether you need a contactor, a soft starter or a VFD.
- Duty class, for example AC-3 for squirrel-cage motors under IEC 60947-4-1.
- Protection split: overload relay plus fuses or MCB, or a single MPCB.
- Control interface: coil voltage, fieldbus such as PROFINET, and mounting.
FAQ
What is the difference between a soft starter and a VFD?
A soft starter limits inrush current during start and stop at fixed supply frequency. A VFD changes the output frequency, so it also controls speed while running.
Do I need a contactor and an overload relay, or an MPCB?
An MPCB combines short-circuit and overload protection and works with a contactor. The separate route uses a fuse or MCB, a contactor and an overload relay. Choose by space, coordination type and rating.
Can you ship motor control products outside Turkey?
Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, and project quantities are quoted on request.