- Home
- All Collections
- Molded Case Circuit Breakers (MCCB)
Molded Case Circuit Breakers (MCCB)
ABB 1SDA100892R1 XT7H 1250 Ekip Dip LS/I In=1250A 3p F F Moulded Case Circuit Breaker
Schneider Electric G20F3A200 GoPact MCCB 3-Pole 200A 36kA Molded Case Circuit Breaker
Schneider Electric LV563307 CVS630F EasyPact CVS 3P 630A 36kA Moulded Case Circuit Breaker
ABB 1SDA100459R1 XT5S 630 TMA 630-6300 4p F F InN=100%In Moulded Case Circuit Breaker 630A 4P Fixed
ABB 1SDA066732R1 A1N 125 TMF 125-1250 3p F F 125A 3-Pole Fixed Moulded Case Circuit Breaker
Schneider Electric G40F3A400 GoPact MCCB 3-Pole 400A 36kA 415V AC Molded Case Circuit Breaker
Schneider Electric C25N3TM250 NSX250N 3P 250A 50kA Moulded Case Circuit Breaker
ABB 1SDA101656R1 XT7S M 1250 Ekip Dip LS/I In1250A 4p F F 4-Pole 1250A Fixed Moulded Case Circuit Breaker
ABB 1SDA066564R1 A3N 630 TMF 500-5000 3p F F 500A 3-Pole Fixed Molded Case Circuit Breaker
ABB 1SDA100455R1 XT5S 400 TMA 400-4000 4p F F InN=100%In Moulded Case Circuit Breaker 400A 4P Fixed
ABB 1SDA100754R1 XT6S 800 Ekip Dip LS/I In=800 4p F F 4-Pole 800A Fixed Moulded Case Circuit Breaker
Schneider Electric LV525302 CVS250B 3-Pole 200A Moulded Case Circuit Breaker EasyPact CVS Series
ABB 1SDA066432R1 AUX-C 1Q+1SY 250Vac/dc XT2-XT4 W Withdrawable Auxiliary Contact
Schneider Electric G12F3F125 GoPact MCCB 125 3P 125A 30kA 415V Moulded Case Circuit Breaker
Schneider Electric G20B3A100 GoPact MCCB 200 3P 100A 25kA 415V Molded Case Circuit Breaker
Schneider Electric G40F3A320 GoPact MCCB 400 3P 320A 36kA Molded Case Circuit Breaker
ABB 1SDA066729R1 A1N 125 TMF 80-800 3p F F 3-Pole 80A Fixed Moulded Case Circuit Breaker
Schneider Electric LV510315 CVS100B EasyPact CVS 4P 63A 25kA Moulded Case Circuit Breaker
ABB 1SDA067093R1 XT2N 160 Ekip Dip LS/I In=100A 4p F F 4-Pole 100A Fixed Molded Case Circuit Breaker
Schneider Electric G80N3E500 GoPact MCCB 3P 500A 50kA Molded Case Circuit Breaker
Molded case circuit breakers (MCCB) from ABB, Schneider Electric and Siemens protect feeders, motors and distribution boards from about 10 A up to 1600 A. The range covers 3-pole and 4-pole breakers with fixed and adjustable trip units, with more than 1,800 products including accessories. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- ABB Tmax XT MCCBs – XT1 to XT7 frames with thermal-magnetic and Ekip electronic trip units.
- ABB Formula A MCCBs – A1 to A3 frames for general distribution.
- Schneider ComPacT NSX MCCBs – frames from 100 A to 630 A.
- Schneider ComPacT NS MCCBs – breakers from 630 A to 1600 A.
- Schneider GoPact MCCBs – compact breakers up to 800 A.
- Schneider EasyPact CVS MCCBs – CVS100 to CVS630 frames.
- Siemens SENTRON 3VA MCCBs – 3VA1 and 3VA2 breakers up to 1250 A.
- Siemens SENTRON 3VM MCCBs – 3VM1 breakers up to 630 A.
- MCCB Accessories, Releases & Trip Units – releases and trip units.
How to choose
- Frame size and rated current, with the trip unit set to the load current.
- Rated breaking capacity (Icu and Ics) at the system voltage, above the prospective short-circuit current.
- Trip unit: thermal-magnetic for simple feeders, electronic (LSI or LSIG) where selectivity is needed.
- Poles: 3P or 4P according to the neutral arrangement. Standard: IEC 60947-2.
FAQ
What is the difference between an MCCB and an ACB?
An MCCB is a compact molded-case breaker, typically used from tens of amperes to 1600 A. An ACB is a larger, often draw-out breaker for main incomers from 630 A upward.
What do Icu and Ics mean on an MCCB?
Icu is the ultimate breaking capacity. Ics is the service breaking capacity, the share of Icu after which the breaker stays fit for service.
Do you export MCCBs and their accessories?
Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so request a quote with your part numbers and quantities.