- Home
- All Collections
- Molded Case Circuit Breakers (MCCB)
Molded Case Circuit Breakers (MCCB)
ABB 1SDA066137R1 SOR-C A1-A2 220-240Vac-220-250Vdc Shunt Opening Release Accessory for FORMULA Circuit Breaker
Schneider Electric LV540309 CVS400F 4P 400A 36kA Fixed Moulded Case Circuit Breaker
Schneider Electric G40N3A320 GoPact MCCB 3P 320A 50kA 415V Molded Case Circuit Breaker
ABB 1SDA068059R1 XT3N 250 TMD 250-2500 3p F F 250A 3-Pole Fixed Moulded Case Circuit Breaker
ABB 1SDA067417R1 XT1N 160 TMD 125-1250 3p F F 125A 3-Pole Fixed Moulded Case Circuit Breaker for Transformer Generator Installation Protection
ABB 1SDA067411R1 XT1N 160 TMD 32-450 3p F F 32A 3-Pole Fixed Moulded Case Circuit Breaker Tmax XT1
ABB 1SDA104690R1 XT5 W FP 630A 3p EF EF IEC/UL Withdrawable Fixed Part 630A 3-Pole Chassis Part Power Circuit Breaker
ABB 1SDA100762R1 XT6H 800 TMA 800-8000 3p F F 800A 3-Pole 70kA Fixed Moulded Case Circuit Breaker
ABB 1SDA062116R1 GEAR.MOTOR DEVICE T7M-X1 220...250Vac/dc Accessory for Circuit Breaker (Geared Motor Device)
ABB 1SDA067436R1 XT1S 160 TMD 160-1600 3p F F 160A 3-Pole Fixed Moulded Case Circuit Breaker
ABB 1SDA067558R1 XT2S 160 TMA 100-1000 3p F F 100A 3-Pole 50kA Fixed Moulded Case Circuit Breaker
Schneider Electric G80N3E630 GoPact MCCB 800 3P 630A 50kA 415V Molded Case Circuit Breaker
ABB 1SDA067556R1 XT2S 160 TMA 63-630 3p F F 63A 3P Fixed Moulded Case Circuit Breaker
Schneider Electric LV525332 CVS250F 3P 200A 36kA EasyPact CVS Moulded Case Circuit Breaker
ABB 1SDA067435R1 XT1S 160 TMD 125-1250 3p F F 3-Pole 125A Fixed Moulded Case Circuit Breaker
Schneider Electric G12F3F100 GoPact MCCB 125 3P 100A 30kA 415V Molded Case Circuit Breaker
ABB 1SDA066399R1 UVR-C XT1..XT4 F/P 220-240Vac-220-250Vdc Undervoltage Release Tmax XT Fixed/Plug-in
Siemens 3VA1340-4EF32-0AA0 3VA1 3P 400A 36kA 415V TM240 LI Molded Case Circuit Breaker
Siemens 3VA1580-5EF32-0AA0 3VA1 3P 800A 55kA 415V TM240 LI Molded Case Circuit Breaker
ABB 1SDA054404R1 T5S 630 PR221DS-LS/I In=630 3p F F 630A 3-Pole Fixed Power Circuit Breaker
Molded case circuit breakers (MCCB) from ABB, Schneider Electric and Siemens protect feeders, motors and distribution boards from about 10 A up to 1600 A. The range covers 3-pole and 4-pole breakers with fixed and adjustable trip units, with more than 1,800 products including accessories. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- ABB Tmax XT MCCBs – XT1 to XT7 frames with thermal-magnetic and Ekip electronic trip units.
- ABB Formula A MCCBs – A1 to A3 frames for general distribution.
- Schneider ComPacT NSX MCCBs – frames from 100 A to 630 A.
- Schneider ComPacT NS MCCBs – breakers from 630 A to 1600 A.
- Schneider GoPact MCCBs – compact breakers up to 800 A.
- Schneider EasyPact CVS MCCBs – CVS100 to CVS630 frames.
- Siemens SENTRON 3VA MCCBs – 3VA1 and 3VA2 breakers up to 1250 A.
- Siemens SENTRON 3VM MCCBs – 3VM1 breakers up to 630 A.
- MCCB Accessories, Releases & Trip Units – releases and trip units.
How to choose
- Frame size and rated current, with the trip unit set to the load current.
- Rated breaking capacity (Icu and Ics) at the system voltage, above the prospective short-circuit current.
- Trip unit: thermal-magnetic for simple feeders, electronic (LSI or LSIG) where selectivity is needed.
- Poles: 3P or 4P according to the neutral arrangement. Standard: IEC 60947-2.
FAQ
What is the difference between an MCCB and an ACB?
An MCCB is a compact molded-case breaker, typically used from tens of amperes to 1600 A. An ACB is a larger, often draw-out breaker for main incomers from 630 A upward.
What do Icu and Ics mean on an MCCB?
Icu is the ultimate breaking capacity. Ics is the service breaking capacity, the share of Icu after which the breaker stays fit for service.
Do you export MCCBs and their accessories?
Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so request a quote with your part numbers and quantities.