- Home
- All Collections
- Molded Case Circuit Breakers (MCCB)
Molded Case Circuit Breakers (MCCB)
Schneider Electric LV525333 CVS250F 3P 250A 36kA Fixed Backplate Moulded Case Circuit Breaker EasyPact CVS
ABB 1SDA067092R1 XT2N 160 Ekip Dip LS/I In=63A 4p F F 4-Pole 63A Fixed Molded Case Circuit Breaker
ABB 1SDA067557R1 XT2S 160 TMA 80-800 3p F F 80A 3-Pole Fixed 50kA Moulded Case Circuit Breaker
ABB 1SDA054897R1 MOE T4-T5 220...250 Vac/dc Motor Operator Accessory for Molded Case Circuit Breaker
Schneider Electric LV563506 CVS630F EasyPact CVS 630A 4P Moulded Case Circuit Breaker
Schneider Electric G12F3F40 GoPact MCCB 3P 40A 30kA Molded Case Circuit Breaker
ABB 1SDA066507R1 A1N 125 TMF 125-1250 2p F F 125A 2-Pole Fixed Moulded Case Circuit Breaker
Schneider Electric C25F6TM250 NSX250F 4P 250A 36kA Moulded Case Circuit Breaker
Schneider Electric C25F3TM250 NSX250F 3P 250A 36kA Moulded Case Circuit Breaker
ABB 1SDA067433R1 XT1S 160 TMD 80-800 3p F F 3-Pole 80A Fixed Moulded Case Circuit Breaker
Schneider Electric C080N320FM ComPacT NS800N 3P 800A 50kA Fixed Molded-Case Circuit Breaker
ABB 1SDA100893R1 XT7H 1600 Ekip Dip LS/I In=1600A 3p F F Moulded Case Circuit Breaker for Transformer, Generator & Installation Protection
ABB 1SDA068312R1 XT4S 250 TMA 250-2500 3p F F 250A 3-Pole Fixed Moulded Case Circuit Breaker
ABB 1SDA067769R1 XT2S 160 MA 100 Im=600...1400 3p F F 100A 3-Pole Fixed Moulded Case Circuit Breaker
Schneider Electric G12F3F32 GoPact MCCB 125 3P 32A 30kA 415V Molded Case Circuit Breaker
ABB 1SDA068475R1 XT4S 250 Ekip Dip LS/I In=250A 3p F F 250A 3-Pole Fixed Moulded Case Circuit Breaker
Schneider Electric G40F3A250 GoPact MCCB 3P 250A 36kA Moulded Case Circuit Breaker
ABB 1SDA101982R1 UVD XT5-XT6 220..250Va.c./d.c. Time Delay Under Voltage Coil Tmax XT
ABB 1SDA068070R1 XT3N 250 TMD 250-2500 4p F F InN=100% 250A 4-Pole Fixed Moulded Case Circuit Breaker
ABB 1SDA066150R1 AUX-C 2Q+1SY 250 Va.c/d.c. A1-A2 3p-4p Auxiliary Contact Accessory for Circuit Breaker
Molded case circuit breakers (MCCB) from ABB, Schneider Electric and Siemens protect feeders, motors and distribution boards from about 10 A up to 1600 A. The range covers 3-pole and 4-pole breakers with fixed and adjustable trip units, with more than 1,800 products including accessories. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- ABB Tmax XT MCCBs – XT1 to XT7 frames with thermal-magnetic and Ekip electronic trip units.
- ABB Formula A MCCBs – A1 to A3 frames for general distribution.
- Schneider ComPacT NSX MCCBs – frames from 100 A to 630 A.
- Schneider ComPacT NS MCCBs – breakers from 630 A to 1600 A.
- Schneider GoPact MCCBs – compact breakers up to 800 A.
- Schneider EasyPact CVS MCCBs – CVS100 to CVS630 frames.
- Siemens SENTRON 3VA MCCBs – 3VA1 and 3VA2 breakers up to 1250 A.
- Siemens SENTRON 3VM MCCBs – 3VM1 breakers up to 630 A.
- MCCB Accessories, Releases & Trip Units – releases and trip units.
How to choose
- Frame size and rated current, with the trip unit set to the load current.
- Rated breaking capacity (Icu and Ics) at the system voltage, above the prospective short-circuit current.
- Trip unit: thermal-magnetic for simple feeders, electronic (LSI or LSIG) where selectivity is needed.
- Poles: 3P or 4P according to the neutral arrangement. Standard: IEC 60947-2.
FAQ
What is the difference between an MCCB and an ACB?
An MCCB is a compact molded-case breaker, typically used from tens of amperes to 1600 A. An ACB is a larger, often draw-out breaker for main incomers from 630 A upward.
What do Icu and Ics mean on an MCCB?
Icu is the ultimate breaking capacity. Ics is the service breaking capacity, the share of Icu after which the breaker stays fit for service.
Do you export MCCBs and their accessories?
Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so request a quote with your part numbers and quantities.