- Home
- All Collections
- Low Voltage Fuse Links (NH, BS88, Cylindrical)
Low Voltage Fuse Links (NH, BS88, Cylindrical)
Mersen B212061 FR10GG50V1 Cylindrical fuse-link gG Size 10x38 IEC 500VAC 1A
Mersen B211026 FR8GG40V8I Cylindrical fuse-link gG Size 8x32 IEC 400VAC 8A With Visual Indicator
Mersen A214613 FR8GG40V10 Cylindrical fuse-link gG Size 8x32 IEC 400VAC 10A
Mersen A214107 FR10GG40V32 Cylindrical fuse-link gG Size 10x38 IEC 400VAC IEC 250VDC 32A
Mersen A212060 FR8GG40V10I Cylindrical fuse-link gG Size 8x32 IEC 400VAC 10A With Visual Indicator
Mersen A211025 FR8GG40V6 Cylindrical fuse-link gG Size 8x32 IEC 400VAC 6A
Mersen A084801 FR10GG40V10P Cylindrical fuse-link gG Size 10x38 IEC 400VAC 10A With Striker
Mersen S218194 FR10GG50V10 Cylindrical fuse-link gG Size 10x38 IEC 500VAC 10A
Siemens 5SE2363 5SE2 63A 400V Fuse
Siemens 5SE2350 5SE2 50A 400V Fuse
Siemens 5SE2340 5SE2 40A 400V Fuse
Siemens 5SE2335 5SE2 35A 400V Fuse
Siemens 5SE2332 5SE2 32A 400V Fuse
Siemens 5SE2325 5SE2 25A 400V Fuse
Siemens 5SE2320 5SE2 20A 400V Fuse
Siemens 5SE2316 5SE2 16A 400V Fuse
Siemens 5SE2310 5SE2 10A 400V Fuse
Siemens 5SE2306 5SE2 6A 400V Fuse
Siemens 5SE2304 5SE2 4A 400V Fuse
Siemens 5SE2302 5SE2 2A 400V Fuse
Low voltage fuse links from Siemens, Mersen, ABB and Schneider Electric cover NH, BS88 and cylindrical formats from 0.5 A to 1250 A. The range holds over 450 products, including Siemens 3NA3 and 3NA6, Mersen DIN CNN and BS88 links, and ABB OFAF links. Stoklink ships worldwide from Turkey on EXW terms, and quotes for project volumes are available on request.
What's in this range
- NH fuse links such as Siemens 3NA3 and 3NA6 and ABB OFAF for panel and feeder protection.
- BS88 links, including feeder pillar gU types at 415 VAC.
- Cylindrical ferrule links, for example 10x38 gG types rated 400 to 690 VAC.
- UL and DIN CNN and CNL blade fuses for North American and DIN-style equipment.
- Siemens 3NP1 and 3NW6 series fuse parts for fuse switch and holder systems.
How to choose
- Operating class: gG protects cables, aM protects motor circuits and tolerates starting current.
- Rated current and voltage: select from the load current and the line voltage, such as 400, 500 or 690 VAC.
- Size: NH00 to NH4, BS88 or 10x38 must fit the base or holder you already have.
- Breaking capacity: compare it with the prospective short-circuit current, typically stated in kA on the datasheet.
- Standard: IEC 60269 for NH and cylindrical links, BS 88 for British Standard types.
FAQ
What does gG mean on a fuse link?
gG is a full-range, general-purpose class under IEC 60269. It clears both overloads and short circuits, so it protects cables and general loads.
Are NH and BS88 fuses interchangeable?
No. The dimensions and contact systems differ, so a BS88 link does not fit an NH base. Match the link to the base or holder size.
How are orders shipped?
Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, and quotes for larger quantities are available.