- Home
- All Collections
- Contactors
Contactors
Siemens 5TT5800-0 5TT5 20A 230V Contactor
Siemens 5TT5801-0 5TT5 20A 230V Contactor
Schneider Electric A9C22813 iCT 3-Pole 16A 220-240V AC Contactor
Schneider Electric LC1D40AE7 TeSys Deca 3-Pole 40A 480V AC 30HP 100kA SCCR Power Contactor
ABB GJL1201317R0001 CA6-11K Auxiliary Contact Block 1NO/1NC 690V AC Side Mounted Screw Terminal
Schneider Electric LC1D12B7 TeSys Deca 3-Pole 12A 480V AC 7.5HP Contactor
ABB 1SBH137001R1171 NF71E-11 8-Pole 24-60V AC/DC NF Series Contactor Relay
ABB GJL1201330R0004 CAF6-11N 1NO/1NC 2P Front Mount Auxiliary Contact Block Screw Terminal
Schneider Electric LC1D38B7 TeSys D 3P 38A 18.5kW AC-3 Coil 24V AC Contactor
ABB 1SBH137001R1153 NF53E-11 8-Pole 24-60V AC/DC Contactor Relay
Schneider Electric LC1D12M7 TeSys Deca 3-Pole 12A 480V AC 7.5HP 100kA SCCR Contactor
Schneider Electric A9C20843 iCT 3-Pole 40A 220-240V AC Contactor
Schneider Electric LC1D65AE7 TeSys Deca 3-Pole 65A 40HP 480V AC Coil Contactor
ABB 1SFL587102R1311 AF305-40-11-13 4-Pole 500A 1000V AC-1 160kW Power Contactor AC Switching
ABB 1SBH101001R2622 NS22E-26 230V 50/60Hz 4-Pole Contactor Relay
Siemens 3RT1975-5AP31 3RT1 240V Contactor
Siemens 3RT2015-1BB41 3RT2 7A 3P 400V Contactor
Siemens 3RT2015-2BB41 3RT2 7A 3P 400V Contactor
ABB 1SBH137001R1380 NF80E-13 8-Pole 100-250V AC/DC Contactor Relay
ABB 1SBL121001R2601 AS16-30-01-26 3-Pole 230V 690V AC Power Contactor AC Switching
Contactors from ABB, Schneider Electric and Siemens switch motor and load circuits on and off by remote control. This range covers over 900 products, from 2 A accessories to power contactors rated up to 2650 A, with motor ratings from 2.2 kW to 450 kW in 2, 3, 4 and 8 pole versions. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- Power Contactors (AC-3) – the main motor-switching contactors, including ABB AF, TeSys Deca, TeSys Giga, TeSys K, Easy TeSys and SIRIUS 3RT2 and 3RT1.
- Contactor Relays & Auxiliary Contactors – control-circuit relays with several auxiliary contacts.
- Installation Contactors – DIN-rail contactors for distribution boards, such as ABB ESB.
- Contactor Accessories (Coils, Aux Blocks) – replacement coils, auxiliary contact blocks and mounting parts.
How to choose
- Utilization category: AC-3 for squirrel-cage motor starting, AC-1 for resistive loads. The same frame carries a different current in each category.
- Rated current and motor power at your operating voltage, with margin for the duty cycle.
- Number of poles: 3P for three-phase motors, 4P for switching the neutral or four-wire loads.
- Coil voltage and type (AC, DC or AC/DC). It must match the control supply.
- Auxiliary contacts: count the NO and NC contacts the control circuit needs, and check if the contactor accepts add-on blocks.
FAQ
What is the difference between a contactor and a contactor relay?
A power contactor switches the main circuit of a motor or load. A contactor relay switches control circuits at low current, typically 10 A, and has more auxiliary contacts.
Which standard applies to contactors?
Low-voltage contactors are covered by IEC 60947-4-1. The standard defines utilization categories such as AC-1 and AC-3.
Do you ship contactors outside Turkey?
Yes. Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so send the part numbers for a quote. Project quantities are quoted on request.