Contactors for Data Center PDU and UPS Systems: Selection Guide
AC-1 and AC-6a contactors for data center PDU and UPS systems: sizing, harmonic derating, coil selection, and endurance guidance for engineers. Shop at Stoklink.
The Siemens 3RT1975-5AP31 is a contactor from the SENTRON/SIRIUS 3RT1 series. Changeover operating mechanism for contactors 3RT107, 3RT147, AC (50...60 Hz) / DC operation, 220 ... 240 V Operating mechanism: Standard,economy circuit Screw terminal. Supplied by Stoklink for industrial and commercial low-voltage applications.
The Siemens 3RT1975-5AP31 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RT1 range it integrates with compatible SENTRON/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.
| product brand name | SIRIUS |
|---|---|
| product category | Solenoid coils |
| product designation | Changeover operating mechanism |
| product type designation | 3RT19 |
| Substance Prohibitance (day/month/year) | 05/01/2012 |
|---|---|
| type of voltage of the control supply voltage | AC/DC |
| control supply voltage 1 at AC: at 50 Hz | 220 ... 240 V |
| control supply voltage 1 at AC: at 60 Hz | 220 ... 240 V |
| control supply voltage 1 at DC | 220 ... 240 V |
| apparent pick-up power of magnet coil at AC: at 50 Hz | 830 V·A |
| apparent pick-up power of magnet coil at AC: at 60 Hz | 830 V·A |
| inductive power factor with closing power of the coil: at 50 Hz | 0.9 |
| inductive power factor with closing power of the coil: at 60 Hz | 0.9 |
| apparent holding power of magnet coil at AC: at 50 Hz | 9.2 V·A |
| apparent holding power of magnet coil at AC: at 60 Hz | 9.2 V·A |
| inductive power factor with the holding power of the coil: at 50 Hz | 0.9 |
| Part number | 3RT1975-5AP31 |
|---|---|
| Type designation | 3RT19 |
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 4011209506398 |
| ETIM class | EC001043 |
| eCl@ss | 27371012 |
| Net weight | 1.139 kg |
|---|---|
| Package dimensions | 176 × 126 × 115 mm |
| Country of origin | DE |
| Shipping weight | 1.639 kg |
| Ships from | Türkiye |
| Dispatch | 18 Nov |
| Stock | Low stock |
Source: manufacturer data · Last verified: 29 Oct 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated operational voltage of 3RT19 is 240 V AC.
The EAN (GTIN) of 3RT19 is 4011209506398.
3RT19 ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival. Stock items are dispatched within 1–2 business days.
AC-1 and AC-6a contactors for data center PDU and UPS systems: sizing, harmonic derating, coil selection, and endurance guidance for engineers. Shop at Stoklink.
Compare AC3 rating IEC contactors versus NEMA size codes, with cross-reference tables, derating formulas, and selection tips for engineers. Shop at Stoklink.
Master AC3 rating selection with our complete contactor checklist covering load sizing, utilization categories, derating, and coordination. Shop at Stoklink.