- Home
- All Collections
- Contactors
Contactors
Siemens 3RT2326-1AP00 3RT2 40A 4P 400V Contactor
Siemens 3RT2327-1AP00 3RT2 50A 4P 400V Contactor
Siemens 5TT5832-0 5TT5 25A 230V Contactor
Schneider Electric LC1D18B7 TeSys D 3P 18A 7.5kW 24V AC Coil Power Contactor
Schneider Electric LC1DT20M7 TeSys Deca 4-Pole 20A IEC Contactor
ABB 1SBH101001R2653 NS53E-26 230V 50/60Hz 8-Pole Contactor Relay
Schneider Electric LA1KN22 TeSys K 2NO+2NC Top Mount Contactor Auxiliary Contact Block
Schneider Electric LADN01 TeSys D 1NC Front Mount Auxiliary Contact Block
ABB 1SBN081006T1000 BEA16-3 Connecting Link with Manual Motor Starter Low-Voltage Switch Technology Accessory
ABB 1SBH101001R2640 NS40E-26 4-Pole 230V AC 50/60Hz Contactor Relay
Schneider Electric LC1D50AB7 TeSys Deca 3-Pole 50A 40HP 480V AC Coil 24V AC Contactor
Schneider Electric LC1D32B7 TeSys Deca 3-Pole 32A 20HP 480V AC Contactor
ABB 1SFL487102R1111 AF190-40-11-11 4-Pole 275A 1000V AC-1 90kW Power Contactor AC Switching
Schneider Electric LC1D25B7 TeSys Deca 3-Pole 25A 480V AC 15HP Power Contactor
Schneider Electric LC1E40B5 EasyPact TVS 3-Pole 40A 440V AC Contactor
Siemens 3RT1364-6AP36 3RT1 350A 4P 400V Contactor
Siemens 3RT1375-6AP36 3RT1 525A 4P 400V Contactor
Siemens 3RT2025-1BB40 3RT2 17A 3P 400V Contactor
Siemens 3RT2317-1AP00 3RT2 22A 4P 400V Contactor
Siemens 3RT2337-1AP00 3RT2 110A 4P 400V Contactor
Contactors from ABB, Schneider Electric and Siemens switch motor and load circuits on and off by remote control. This range covers over 900 products, from 2 A accessories to power contactors rated up to 2650 A, with motor ratings from 2.2 kW to 450 kW in 2, 3, 4 and 8 pole versions. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- Power Contactors (AC-3) – the main motor-switching contactors, including ABB AF, TeSys Deca, TeSys Giga, TeSys K, Easy TeSys and SIRIUS 3RT2 and 3RT1.
- Contactor Relays & Auxiliary Contactors – control-circuit relays with several auxiliary contacts.
- Installation Contactors – DIN-rail contactors for distribution boards, such as ABB ESB.
- Contactor Accessories (Coils, Aux Blocks) – replacement coils, auxiliary contact blocks and mounting parts.
How to choose
- Utilization category: AC-3 for squirrel-cage motor starting, AC-1 for resistive loads. The same frame carries a different current in each category.
- Rated current and motor power at your operating voltage, with margin for the duty cycle.
- Number of poles: 3P for three-phase motors, 4P for switching the neutral or four-wire loads.
- Coil voltage and type (AC, DC or AC/DC). It must match the control supply.
- Auxiliary contacts: count the NO and NC contacts the control circuit needs, and check if the contactor accepts add-on blocks.
FAQ
What is the difference between a contactor and a contactor relay?
A power contactor switches the main circuit of a motor or load. A contactor relay switches control circuits at low current, typically 10 A, and has more auxiliary contacts.
Which standard applies to contactors?
Low-voltage contactors are covered by IEC 60947-4-1. The standard defines utilization categories such as AC-1 and AC-3.
Do you ship contactors outside Turkey?
Yes. Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so send the part numbers for a quote. Project quantities are quoted on request.