- Home
- All Collections
- Contactors
Contactors
ABB GJL1201317R0004 CA6-11N 1NO+1NC Side Mount Auxiliary Contact Block 690V AC 2P Screw Terminal
Schneider Electric LC1K0901B7 TeSys K 3-Pole 9A 440V Coil 24V AC Contactor
Schneider Electric LC1D50AM7 TeSys Deca 3-Pole 50A 480VAC 40HP 100kA SCCR AC Contactor
ABB GJL1213001R0011 BC6-30-01-01 Mini Power Contactor AC Switching 3NO 20A 4kW 24V DC Coil Screw Terminals
Schneider Electric LC1D40AF7 TeSys Deca 3-Pole 40A 480V AC 30HP 100kA SCCR Contactor
Schneider Electric LC1D18E7 TeSys Deca 3-Pole 18A 480V AC 10HP Motor Contactor
Siemens 3RT1975-6A 3RT1 Contactor
Siemens 3RT2018-1AP01 3RT2 16A 3P 400V Contactor
Siemens 3RT2646-1AP03 3RT2 144A 3P 400V Contactor
Siemens 3RT2916-1CD00 3RT2 240V Contactor
Schneider Electric LC1D95B7 TeSys Deca 3-Pole 95A 480V AC 60HP Power Contactor
ABB GJL1201330R0008 CAF6-20N 2NO Front Mounted Screw Terminal Auxiliary Contact Block
ABB 1SFL467001R1111 AF146-30-11-11 3-Pole 225A 1000V AC-1 75kW Power Contactor AC Switching
Schneider Electric LC1K0610M7 TeSys K 3P 6A 2.2kW 220V AC Coil Contactor
Schneider Electric LA1KN11 TeSys K 1NO+1NC Front Mount Auxiliary Contact Block
Siemens 3RT1055-6AP36 3RT1 150A 3P 400V Contactor
Siemens 3RT1064-6AP36 3RT1 225A 3P 400V Contactor
Siemens 3RT2018-2BB42 3RT2 16A 3P 400V Contactor
Siemens 3RT2023-1BB40 3RT2 9A 3P 400V Contactor
Siemens 3RT2035-1AP00 3RT2 41A 3P 400V Contactor
Contactors from ABB, Schneider Electric and Siemens switch motor and load circuits on and off by remote control. This range covers over 900 products, from 2 A accessories to power contactors rated up to 2650 A, with motor ratings from 2.2 kW to 450 kW in 2, 3, 4 and 8 pole versions. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- Power Contactors (AC-3) – the main motor-switching contactors, including ABB AF, TeSys Deca, TeSys Giga, TeSys K, Easy TeSys and SIRIUS 3RT2 and 3RT1.
- Contactor Relays & Auxiliary Contactors – control-circuit relays with several auxiliary contacts.
- Installation Contactors – DIN-rail contactors for distribution boards, such as ABB ESB.
- Contactor Accessories (Coils, Aux Blocks) – replacement coils, auxiliary contact blocks and mounting parts.
How to choose
- Utilization category: AC-3 for squirrel-cage motor starting, AC-1 for resistive loads. The same frame carries a different current in each category.
- Rated current and motor power at your operating voltage, with margin for the duty cycle.
- Number of poles: 3P for three-phase motors, 4P for switching the neutral or four-wire loads.
- Coil voltage and type (AC, DC or AC/DC). It must match the control supply.
- Auxiliary contacts: count the NO and NC contacts the control circuit needs, and check if the contactor accepts add-on blocks.
FAQ
What is the difference between a contactor and a contactor relay?
A power contactor switches the main circuit of a motor or load. A contactor relay switches control circuits at low current, typically 10 A, and has more auxiliary contacts.
Which standard applies to contactors?
Low-voltage contactors are covered by IEC 60947-4-1. The standard defines utilization categories such as AC-1 and AC-3.
Do you ship contactors outside Turkey?
Yes. Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so send the part numbers for a quote. Project quantities are quoted on request.