Filter

Switch Disconnectors & Transfer Switches Categories

Switch Disconnectors & Transfer Switches

Filter
Showing 1 - 340 of 552 items

Siemens 3KF3325-0MF11 3KF3 250A 3P 690V Switch Disconnector

Reference No: 3KF3325-0MF11
Catalog No: 3KF3325-0MF11
Rated Current (A): 250
Rated Voltage (VAC): 690 V
Number of Poles: 3P
10 pcs in stock
$600.38

Siemens 3KF3325-0LF11 3KF3 250A 3P 690V Switch Disconnector

Reference No: 3KF3325-0LF11
Catalog No: 3KF3325-0LF11
Rated Current (A): 250
Rated Voltage (VAC): 690 V
Number of Poles: 3P
0 pcs in stock
$600.38

Siemens 3KF2316-0MF11 3KF2 160A 3P 690V Switch Disconnector

Reference No: 3KF2316-0MF11
Catalog No: 3KF2316-0MF11
Rated Current (A): 160
Rated Voltage (VAC): 690 V
Number of Poles: 3P
27 pcs in stock
$346.27

Siemens 3KF2316-0LF11 3KF2 160A 3P 690V Switch Disconnector

Reference No: 3KF2316-0LF11
Catalog No: 3KF2316-0LF11
Rated Current (A): 160
Rated Voltage (VAC): 690 V
Number of Poles: 3P
0 pcs in stock
$346.27

Siemens 3KF2312-0MF11 3KF2 125A 3P 690V Switch Disconnector

Reference No: 3KF2312-0MF11
Catalog No: 3KF2312-0MF11
Rated Current (A): 125
Rated Voltage (VAC): 690 V
Number of Poles: 3P
1 pcs in stock
$275.23

Siemens 3KF2312-0LF11 3KF2 125A 3P 690V Switch Disconnector

Reference No: 3KF2312-0LF11
Catalog No: 3KF2312-0LF11
Rated Current (A): 125
Rated Voltage (VAC): 690 V
Number of Poles: 3P
1 pcs in stock
$275.23

Siemens 3KD9508-8 3KD9 Switch Disconnector

Reference No: 3KD9508-8
Catalog No: 3KD9508-8
0 pcs in stock
$89.73

Siemens 3KD9508-6 3KD9 Switch Disconnector

Reference No: 3KD9508-6
Catalog No: 3KD9508-6
0 pcs in stock
$67.47

Siemens 3KD9506-0 3KD9 Switch Disconnector

Reference No: 3KD9506-0
Catalog No: 3KD9506-0
0 pcs in stock
$609.65

Siemens 3KD9505-0 3KD9 Switch Disconnector

Reference No: 3KD9505-0
Catalog No: 3KD9505-0
0 pcs in stock
$912.97

Siemens 3KD9504-6 3KD9 Switch Disconnector

Reference No: 3KD9504-6
Catalog No: 3KD9504-6
12 pcs in stock
$151.43

Siemens 3KD9501-2 3KD9 Switch Disconnector

Reference No: 3KD9501-2
Catalog No: 3KD9501-2
0 pcs in stock
$99.23

Siemens 3KD9501-1 3KD9 Switch Disconnector

Reference No: 3KD9501-1
Catalog No: 3KD9501-1
0 pcs in stock
$99.23

Siemens 3KD9408-8 3KD9 Switch Disconnector

Reference No: 3KD9408-8
Catalog No: 3KD9408-8
0 pcs in stock
$67.47

Siemens 3KD9408-6 3KD9 Switch Disconnector

Reference No: 3KD9408-6
Catalog No: 3KD9408-6
0 pcs in stock
$50.93

Siemens 3KD9406-0 3KD9 Switch Disconnector

Reference No: 3KD9406-0
Catalog No: 3KD9406-0
0 pcs in stock
$201.85

Siemens 3KD9405-0 3KD9 Switch Disconnector

Reference No: 3KD9405-0
Catalog No: 3KD9405-0
0 pcs in stock
$302.36

Siemens 3KD9404-7 3KD9 Switch Disconnector

Reference No: 3KD9404-7
Catalog No: 3KD9404-7
0 pcs in stock
$69.07

Siemens 3KD9404-6 3KD9 Switch Disconnector

Reference No: 3KD9404-6
Catalog No: 3KD9404-6
17 pcs in stock
$70.45

Siemens 3KD9401-2 3KD9 Switch Disconnector

Reference No: 3KD9401-2
Catalog No: 3KD9401-2
0 pcs in stock
$69.07

Switch disconnectors and transfer switches from ABB, Siemens, Schneider Electric and Mersen, covering isolation, manual changeover, automatic transfer and cam switching from 6 A up to 3800 A. The range includes 1P to 4P devices, with 3P and 4P the most common. Stoklink ships worldwide from Turkey and quotes project volumes on request.

What's in this range

How to choose

  • Rated current and utilization category. Match the AC-22 or AC-23 duty to the load, and size for the full load current.
  • Pole count. Use 4P where the neutral must be switched, for example when changing between two sources.
  • Voltage and short-circuit withstand. Check the rating against the fault level at the installation point.
  • Control method. Manual operation suits most panels. Choose motorized or automatic transfer when the change must happen without an operator.
  • Mounting. Pick DIN-rail, base, door-coupled or enclosed to fit the panel layout.

FAQ

What is the difference between a switch disconnector and a circuit breaker?

A switch disconnector isolates and switches load current but gives no overcurrent protection. A circuit breaker also trips on overload and short circuit, so a protective device is normally installed upstream of the switch.

When should I use an ATS instead of a manual changeover switch?

Use an ATS when the transfer must happen automatically after a mains failure, for example to a generator. A manual changeover switch needs an operator and suits sites where short outages are acceptable.

Do you ship outside Turkey?

Yes. Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, and we quote project quantities on request.