- Home
- All Collections
- Residual Current Devices (RCD)
Residual Current Devices (RCD)
Siemens 5SV3345-6 5SV3 125A 4P 400V Residual Current Device
Siemens 5SV3344-6 5SV3 40A 4P 400V Residual Current Device
Siemens 5SV3344-4 5SV3 40A 4P 400V Residual Current Device
Siemens 5SV3342-6 5SV3 25A 4P 400V Residual Current Device
Siemens 5SV3342-4 5SV3 25A 4P 400V Residual Current Device
Siemens 5SV3326-4 5SV3 63A 2P 230V Residual Current Device
Siemens 5SV3324-4 5SV3 40A 2P 230V Residual Current Device
Siemens 5SV3322-4 5SV3 25A 2P 230V Residual Current Device
Siemens 5SV3321-4 5SV3 16A 2P 230V Residual Current Device
Siemens 5SV3317-6 5SV3 80A 2P 230V Residual Current Device
Siemens 5SV3316-6 5SV3 63A 2P 230V Residual Current Device
Siemens 5SV3314-6 5SV3 40A 2P 230V Residual Current Device
Siemens 5SV3312-6 5SV3 25A 2P 230V Residual Current Device
Siemens 5SV3311-6 5SV3 16A 2P 230V Residual Current Device
Siemens 5SV3111-6 5SV3 16A 2P 230V Residual Current Device
Siemens 5SV1313-7KK16 5SV1 16A 2P Residual Current Device
Siemens 5SV1313-7KK10 5SV1 10A 2P Residual Current Device
Siemens 5SV1313-7KK06 5SV1 6A 2P Residual Current Device
Siemens 5SV1313-7KK04 5SV1 4A 2P Residual Current Device
Siemens 5SV1313-7KK02 5SV1 2A 2P Residual Current Device
Residual current devices (RCD) from ABB, Siemens and Schneider Electric detect earth leakage and disconnect the circuit before it becomes a shock or fire risk. The range covers RCCBs, RCBOs and add-on blocks in 1+N, 2, 3 and 4 poles, with sensitivities from 30 mA to 300 mA. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- RCCB (Residual Current Circuit Breakers) – earth leakage protection only, used with an upstream MCB or fuse.
- RCBO (Residual Current Breakers with Overcurrent Protection) – leakage, overload and short-circuit protection in one device.
- RCD Add-on Blocks & Earth Leakage Relays – blocks that clip onto an MCB, and relays for leakage monitoring.
How to choose
- Sensitivity: 30 mA for personal protection, 100 to 300 mA for fire protection and selectivity.
- Type: AC, A or B, depending on whether the load can produce pulsating or smooth DC leakage, as with drives and inverters.
- Rated current and poles: the RCD must carry the total load of the circuits behind it. Match 2P to single-phase and 4P to three-phase with neutral.
- Standard: IEC 61008-1 for RCCBs and IEC 61009-1 for RCBOs.
- Selectivity: use a time-delayed or S-type RCD upstream of an instantaneous one.
FAQ
What is the difference between an RCCB and an RCBO?
An RCCB only detects earth leakage, so it needs a separate MCB or fuse for overload and short-circuit protection. An RCBO combines both in one module.
Which RCD type do I need for a variable frequency drive?
Drives can produce DC leakage components that Type AC and Type A devices may not detect. Type B is normally specified for three-phase drive circuits. Check the drive manual.
Do you ship RCDs outside Turkey?
Yes. Stoklink ships worldwide from Turkey, EXW. Lead time depends on distributor stock, and we quote bulk project volumes on request.