- Home
- All Collections
- Residual Current Devices (RCD)
Residual Current Devices (RCD)
Siemens 5SU1326-6FP10 5SU1 10A 2P 230V Residual Current Breaker (RCBO)
Siemens 5SU1326-6FP06 5SU1 06A 2P 230V Residual Current Breaker (RCBO)
Siemens 5SV8900-1KK 5SV8 Residual Current Device
Siemens 5SV8706-0KK 5SV8 630A Residual Current Device
Siemens 5SV8705-0KK 5SV8 500A Residual Current Device
Siemens 5SV8704-0KK 5SV8 250A Residual Current Device
Siemens 5SV8703-0KK 5SV8 200A Residual Current Device
Siemens 5SV8702-0KK 5SV8 80A Residual Current Device
Siemens 5SV8001-6KK 5SV8 0.03A 230V Residual Current Device
Siemens 5SV8000-6KK 5SV8 0.03A 230V Residual Current Device
Siemens 5SV6016-7KK40 5SV6 40A 2P 230V Residual Current Device
Siemens 5SV6016-7KK32 5SV6 32A 2P 230V Residual Current Device
Siemens 5SV6016-7KK25 5SV6 25A 2P 230V Residual Current Device
Siemens 5SV6016-7KK20 5SV6 20A 2P 230V Residual Current Device
Siemens 5SV6016-7KK16 5SV6 16A 2P 230V Residual Current Device
Siemens 5SV6016-7KK10 5SV6 10A 2P 230V Residual Current Device
Siemens 5SV6016-7KK06 5SV6 6A 2P 230V Residual Current Device
Siemens 5SV5646-6 5SV5 63A 4P 400V Residual Current Device
Siemens 5SV5644-6 5SV5 40A 4P 400V Residual Current Device
Siemens 5SV5642-6 5SV5 25A 4P 400V Residual Current Device
Residual current devices (RCD) from ABB, Siemens and Schneider Electric detect earth leakage and disconnect the circuit before it becomes a shock or fire risk. The range covers RCCBs, RCBOs and add-on blocks in 1+N, 2, 3 and 4 poles, with sensitivities from 30 mA to 300 mA. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- RCCB (Residual Current Circuit Breakers) – earth leakage protection only, used with an upstream MCB or fuse.
- RCBO (Residual Current Breakers with Overcurrent Protection) – leakage, overload and short-circuit protection in one device.
- RCD Add-on Blocks & Earth Leakage Relays – blocks that clip onto an MCB, and relays for leakage monitoring.
How to choose
- Sensitivity: 30 mA for personal protection, 100 to 300 mA for fire protection and selectivity.
- Type: AC, A or B, depending on whether the load can produce pulsating or smooth DC leakage, as with drives and inverters.
- Rated current and poles: the RCD must carry the total load of the circuits behind it. Match 2P to single-phase and 4P to three-phase with neutral.
- Standard: IEC 61008-1 for RCCBs and IEC 61009-1 for RCBOs.
- Selectivity: use a time-delayed or S-type RCD upstream of an instantaneous one.
FAQ
What is the difference between an RCCB and an RCBO?
An RCCB only detects earth leakage, so it needs a separate MCB or fuse for overload and short-circuit protection. An RCBO combines both in one module.
Which RCD type do I need for a variable frequency drive?
Drives can produce DC leakage components that Type AC and Type A devices may not detect. Type B is normally specified for three-phase drive circuits. Check the drive manual.