- Home
- All Collections
- Power Quality, Metering & Power Supplies
Power Quality, Metering & Power Supplies
Power Quality, Metering & Power Supplies Categories
Power Quality, Metering & Power Supplies
Siemens 6EP1332-5BA00 SITOP PSU100C 24V/2.5A AC/DC Power Supply
Siemens 6EP1332-2BA20 SITOP PSU100S 24V DC 2.5A 60W Power Supply
Siemens 6EP1332-1LB00 SITOP PSU100L 24V/2.5A Stabilized Power Supply
Siemens 6EP1331-5BA10 SITOP PSU100C 120-230V AC 24V/1.3A DIN Rail Power Supply
Siemens 6EP1331-5BA00 SITOP PSU100C 24V 0.6A DIN Rail Power Supply
Siemens 6EP1331-1LD01 SITOP PSU100D 24V/2.2A Stabilized Power Supply 100-240V AC Input Power Supply
Siemens 6EP1321-1LD01 SITOP PSU100D 12V/3A Stabilized Power Supply 100-240V AC Input Power Supply
Siemens 6GT2898-0AC00 SIMATIC RF600 Wide-Range Power Supply 24V DC 3A IP67 Power Supply
Siemens 6ES7138-7EC00-0AA0 SIMATIC ET 200iSP PS 120/230V AC Redundant Power Supply
Siemens 6EP7133-6AE00-0BN0 SIMATIC ET 200SP PS 24 V/10 A Power Supply
Siemens 6EP7133-6AB00-0BN0 SIMATIC ET 200SP PS 24V/5A DIN Rail Power Supply
Siemens 6RA8098-4DV62-0AA0 SINAMICS DCM D420/3000 420V DC 3000A Four-Quadrant DC Converter
Siemens 6RA8098-4DS22-0AA0 SINAMICS DCM D485/3000 485V DC 3000A Two-Quadrant DC Converter
Siemens 6RA8095-4DV62-0AA0 SINAMICS DCM D420/2000 420V DC 2000A Four-Quadrant DC Converter
Siemens 6RA8095-4DS22-0AA0 SINAMICS DCM D485/2000 485V DC 2000A Two-Quadrant DC Converter
Siemens 6RA8093-4DV62-0AA0 SINAMICS DCM Four-Quadrant DC Converter 400V AC 1328A / 420V DC 1600A
Siemens 6RA8093-4DS22-0AA0 SINAMICS DCM Two-Quadrant DC Converter 400V AC 1328A / 485V DC 1600A
Siemens 6RA8091-6DV62-0AA0 SINAMICS DCM Four-Quadrant DC Converter 400V AC 996A / 420V DC 1200A
Siemens 6RA8091-6DS22-0AA0 SINAMICS DCM Two-Quadrant DC Converter 400V AC 996A / 485V DC 1200A
Siemens 6RA8087-6DV62-0AA0 SINAMICS DCM Four-Quadrant DC Converter 400V AC 706A / 420V DC 850A
Power quality, metering and power supplies from ABB, Siemens and Schneider Electric: over 700 products for measuring energy, supplying control circuits and correcting power factor in low-voltage panels. The range covers rated currents from under 1 A to 6000 A and DC supplies up to 98.5 kW. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- Energy Meters & Power Analyzers – multifunction meters, energy analyzers and wireless energy sensors for monitoring load and consumption.
- Current Transformers – primary-to-5 A and low-voltage output transformers that feed meters, relays and analyzers.
- Power Supplies – 24 V DC DIN rail units, DC UPS and buffer modules, redundancy and selectivity modules.
- Power Factor Correction – capacitors and related components that reduce reactive power in the installation.
How to choose
- Define the job first: billing-grade energy metering, power quality analysis, control power or reactive compensation each need a different product family.
- Match ratings to the circuit. Meters and transformers follow the primary current and system voltage, supplies follow the load current at 24 V DC, capacitors follow kvar and network voltage.
- Check accuracy class for metering points. Class 0.2S, 0.5 and 1 are common choices depending on whether the data is used for billing or for monitoring.
- Confirm mounting and communication: DIN rail or panel cut-out, Modbus or Ethernet interfaces, and input voltage range of the supply.
FAQ
What is the difference between an energy meter and a power analyzer?
An energy meter mainly records kWh consumption. A power analyzer also measures harmonics, power factor, demand and waveform data, so it suits power quality studies.
Do I need current transformers with every meter?
Not always. Direct-connect meters take current up to their rating. Above that, a meter normally works with current transformers, typically with a 5 A secondary.
Do you ship these products outside Turkey?
Yes. Stoklink ships worldwide from Turkey under EXW terms. Lead time depends on distributor stock, and bulk quotes are available on request.