- Home
- All Collections
- Motor Control & Protection
Motor Control & Protection
Motor Control & Protection Categories
Motor Control & Protection
Schneider Electric LC1D40ABD TeSys Deca 3-Pole 40A 24VDC Coil 480V AC 30HP Power Contactor
Schneider Electric LC1D40AB7 TeSys D 3-Pole 40A 440V AC Contactor
Schneider Electric LC1D38Q7 TeSys Deca Contactor 3P 3NO AC-3 38 A 380 V AC Coil Contactor
Schneider Electric LC1D38M7 TeSys D 3-Pole 38A 440V AC Contactor
Schneider Electric LC1D38FD TeSys Deca Contactor 3P 3NO AC-3 38 A 110 V DC Coil Contactor
Schneider Electric LC1D38E7 TeSys D 3-Pole 38A 440V Coil AC Power Contactor
Schneider Electric LC1D38D7 TeSys Deca Contactor 3P 3NO AC-3 38 A 42 V AC Coil Contactor
Schneider Electric LC1D38BL TeSys Deca 3-Pole 38A 20HP 480VAC Coil 24VDC Contactor
Schneider Electric LC1D38B7 TeSys D 3P 38A 18.5kW AC-3 Coil 24V AC Contactor
Schneider Electric LC1D32V7 TeSys Deca Contactor 3P 3NO AC-3 32 A 400 V AC Coil Contactor
Schneider Electric LC1D32Q7 TeSys Deca 3-Pole 32A 480V AC 20HP Contactor
Schneider Electric LC1D32M7 TeSys Deca 3-Pole 32A 20HP 480V AC Coil 220V Contactor
Schneider Electric LC1D32FD TeSys Deca Contactor 3P 3NO AC-3 32 A 110 V DC Coil Contactor
Schneider Electric LC1D32F7 TeSys Deca 3-Pole 32A 480V AC Coil 20HP Power Contactor
Schneider Electric LC1D32ED TeSys Deca Contactor 3P 3NO AC-3 32 A 48 V DC Coil Contactor
Schneider Electric LC1D32E7 TeSys Deca 3-Pole 32A 480V AC 20HP 100kA SCCR Contactor
Schneider Electric LC1D32D7 TeSys Deca Contactor 3P 3NO AC-3 32 A 42 V AC Coil Contactor
Schneider Electric LC1D32BNE TeSys Deca Contactor 3P 3NO AC-3 32 A 24-60 V AC/DC Coil Contactor
Schneider Electric LC1D32BL TeSys Deca LC1D 32 A 15 kW 24 V DC Contactor
Schneider Electric LC1D32BD TeSys Deca 3-Pole 32A 480V AC 24VDC Coil 20HP Power Contactor
Motor control and protection equipment from ABB, Siemens and Schneider Electric covers everything between the supply and the motor shaft. The range spans contactors, overload relays, motor protection circuit breakers, starters, soft starters, variable frequency drives, servo systems and industrial motors, with rated currents from 0.1 A to 2,650 A and power up to 800 kW. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- Contactors – switching devices for motor and load circuits, mostly 3-pole
- Thermal Overload Relays – bimetal and electronic relays for motor overload protection
- Motor Protection Circuit Breakers (MPCB) – short-circuit and overload protection in one device
- Motor Starters & Motor Management – starter combinations and motor controllers such as TeSys U and SIRIUS 3RK
- Soft Starters – controlled ramp-up for 3-phase motors
- Variable Frequency Drives (VFD) – speed control with ABB ACS, Schneider Altivar and Siemens SINAMICS
- Servo Drives & Motion Control – servo motors, drives, controllers and cables
- Industrial Motors – SIMOTICS asynchronous motors
How to choose
- Motor power and rated current at the supply voltage. Size the starter or drive for the nameplate current, not just the kW value.
- Starting method: direct on line, soft start or variable speed. This decides whether you need a contactor, a soft starter or a VFD.
- Duty class, for example AC-3 for squirrel-cage motors under IEC 60947-4-1.
- Protection split: overload relay plus fuses or MCB, or a single MPCB.
- Control interface: coil voltage, fieldbus such as PROFINET, and mounting.
FAQ
What is the difference between a soft starter and a VFD?
A soft starter limits inrush current during start and stop at fixed supply frequency. A VFD changes the output frequency, so it also controls speed while running.
Do I need a contactor and an overload relay, or an MPCB?
An MPCB combines short-circuit and overload protection and works with a contactor. The separate route uses a fuse or MCB, a contactor and an overload relay. Choose by space, coordination type and rating.
Can you ship motor control products outside Turkey?
Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, and project quantities are quoted on request.