Filter

Motor Control & Protection Categories

Motor Control & Protection

Filter
Showing 1 - 2240 of 3212 items

Schneider Electric GV2ME22 GV2ME 3-Pole 20-25A TeSys Deca Manual Starter and Protector

Reference No: GV2ME22
Rated Current (A): 25
Number of Poles: 3P
100 pcs in stock
$70.68

Schneider Electric GV2ME21 GV2ME 3P 17-23A Manual Motor Starter and Protector TeSys Deca

Reference No: GV2ME21
Rated Current (A): 23
Number of Poles: 3P
100 pcs in stock
$69.14

Schneider Electric GV2ME20 TeSys Deca 3P 13-18A Manual Starter and Protector

Reference No: GV2ME20
Rated Current (A): 18
Number of Poles: 3P
100 pcs in stock
$65.27

Schneider Electric GV2ME16 GV2ME 3P 9-14A Manual Motor Starter and Protector TeSys Deca

Reference No: GV2ME16
Rated Current (A): 14
Number of Poles: 3P
100 pcs in stock
$56.97

Schneider Electric GV2ME14 GV2ME 3-Pole 6-10A Manual Starter and Protector TeSys Deca

Reference No: GV2ME14
Rated Current (A): 10
Number of Poles: 3P
100 pcs in stock
$56.97

Schneider Electric GV2ME10 GV2ME 3P 4-6.3A Manual Starter and Protector TeSys Deca

Reference No: GV2ME10
Rated Current (A): 6.3
Number of Poles: 3P
100 pcs in stock
$53.71

Schneider Electric GV2ME08 GV2ME 3P 2.5-4A TeSys Deca Manual Motor Starter and Protector

Reference No: GV2ME08
Rated Current (A): 4
Number of Poles: 3P
100 pcs in stock
$53.71

Schneider Electric GV2ME07 GV2ME 3P 1.6-2.5A Manual Starter and Protector TeSys Deca

Reference No: GV2ME07
Rated Current (A): 2.5
Number of Poles: 3P
100 pcs in stock
$53.71

Schneider Electric GV2ME05 GV2ME 3-Pole 0.63-1A Manual Starter and Protector TeSys Deca

Reference No: GV2ME05
Rated Current (A): 1
Number of Poles: 3P
100 pcs in stock
$53.03

Schneider Electric GV2ME04 TeSys Deca 3P 0.4-0.63A Manual Starter and Protector

Reference No: GV2ME04
Rated Current (A): 0.63
Number of Poles: 3P
100 pcs in stock
$53.03

Schneider Electric GV2ME03 TeSys Deca 3P 0.25-0.40A Manual Starter and Protector

Reference No: GV2ME03
Rated Current (A): 0.40
Number of Poles: 3P
100 pcs in stock
$53.03

Schneider Electric GV2ME02 GV2ME 3P 0.16-0.25A Manual Starter and Protector TeSys Deca

Reference No: GV2ME02
Rated Current (A): 0.25
Number of Poles: 3P
30 pcs in stock
$60.84

Schneider Electric GV2ME01 TeSys Deca 3P 0.1-0.16A Manual Starter and Protector

Reference No: GV2ME01
Rated Current (A): 0.16
Number of Poles: 3P
55 pcs in stock
$60.84

Schneider Electric GV2LE32 TeSys GV2 3P 32A Manual Starter and Protector Magnetic Circuit Protector

Reference No: GV2LE32
Rated Current (A): 32
Number of Poles: 3P
26 pcs in stock
$117.05

Schneider Electric GV2LE22 TeSys Deca GV2LE 25 A Manual Starter and Protector

Reference No: GV2LE22
Rated Current (A): 25
Number of Poles: 3P
0 pcs in stock
$55.66

Schneider Electric GV2LE20 TeSys Deca GV2LE 18 A Manual Starter and Protector

Reference No: GV2LE20
Rated Current (A): 18
Number of Poles: 3P
0 pcs in stock
$53.83

Schneider Electric GV2LE16 TeSys Deca GV2LE 14A 690V Manual Starter and Protector

Reference No: GV2LE16
Rated Current (A): 14
Number of Poles: 3P
0 pcs in stock
$47.94

Schneider Electric GV2LE14 TeSys Deca GV2LE 10 A Manual Starter and Protector

Reference No: GV2LE14
Rated Current (A): 10
Rated Voltage (VAC): 690 V AC
Number of Poles: 3P
0 pcs in stock
$47.94

Schneider Electric GV2LE10 TeSys Deca GV2LE 6.3A 690V Manual Starter and Protector

Reference No: GV2LE10
Rated Current (A): 6.3
Number of Poles: 3P
0 pcs in stock
$43.33

Schneider Electric GV2LE08 TeSys Deca GV2LE 4A 690V Manual Starter and Protector

Reference No: GV2LE08
Rated Current (A): 4
Number of Poles: 3P
0 pcs in stock
$43.33

Motor control and protection equipment from ABB, Siemens and Schneider Electric covers everything between the supply and the motor shaft. The range spans contactors, overload relays, motor protection circuit breakers, starters, soft starters, variable frequency drives, servo systems and industrial motors, with rated currents from 0.1 A to 2,650 A and power up to 800 kW. Stoklink ships worldwide from Turkey and quotes project volumes on request.

What's in this range

How to choose

  • Motor power and rated current at the supply voltage. Size the starter or drive for the nameplate current, not just the kW value.
  • Starting method: direct on line, soft start or variable speed. This decides whether you need a contactor, a soft starter or a VFD.
  • Duty class, for example AC-3 for squirrel-cage motors under IEC 60947-4-1.
  • Protection split: overload relay plus fuses or MCB, or a single MPCB.
  • Control interface: coil voltage, fieldbus such as PROFINET, and mounting.

FAQ

What is the difference between a soft starter and a VFD?

A soft starter limits inrush current during start and stop at fixed supply frequency. A VFD changes the output frequency, so it also controls speed while running.

Do I need a contactor and an overload relay, or an MPCB?

An MPCB combines short-circuit and overload protection and works with a contactor. The separate route uses a fuse or MCB, a contactor and an overload relay. Choose by space, coordination type and rating.

Can you ship motor control products outside Turkey?

Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, and project quantities are quoted on request.