Schneider Electric GV2RT07 TeSys Deca 3P 1.6-2.5 A 100 kA Motor Protection Circuit Breaker (MPCB)

Reference No: GV2RT07
Rated Current (A): 2.5
Rated Voltage (VAC): 690 V
Number of Poles: 3P
0 pcs in stock
$54.27

Schneider Electric GV2RT06 TeSys Deca 3P 1-1.6 A 100 kA Motor Protection Circuit Breaker (MPCB)

Reference No: GV2RT06
Rated Current (A): 1.6
Rated Voltage (VAC): 690 V
Number of Poles: 3P
0 pcs in stock
$54.27

Schneider Electric GV2RT05 TeSys Deca 3P 0.63-1 A 100 kA Motor Protection Circuit Breaker (MPCB)

Reference No: GV2RT05
Rated Current (A): 1
Rated Voltage (VAC): 690 V
Number of Poles: 3P
0 pcs in stock
$52.75

Schneider Electric GV2RT04 TeSys Deca 3P 0.4-0.63 A 100 kA Motor Protection Circuit Breaker (MPCB)

Reference No: GV2RT04
Rated Current (A): 0.63
Rated Voltage (VAC): 690 V
Number of Poles: 3P
0 pcs in stock
$52.75

Schneider Electric GV2RT03 TeSys Deca 3P 0.25-0.4 A 100 kA Motor Protection Circuit Breaker (MPCB)

Reference No: GV2RT03
Rated Current (A): 0.4
Rated Voltage (VAC): 690 V
Number of Poles: 3P
0 pcs in stock
$52.75

Schneider Electric GV2P32 GV2RT 3-Pole 24-32A TeSys Deca Manual Starter and Protector

Reference No: GV2P32
Rated Current (A): 32
Number of Poles: 3P
87 pcs in stock
$131.39

Schneider Electric GV2P22 GV2RT 3P 20-25A Manual Starter and Protector TeSys Deca

Reference No: GV2P22
Rated Current (A): 25
Number of Poles: 3P
50 pcs in stock
$81.09

Schneider Electric GV2P21 GV2RT 3-Pole 17-23A TeSys Deca Manual Starter and Protector

Reference No: GV2P21
Rated Current (A): 23
Number of Poles: 3P
12 pcs in stock
$81.09

Schneider Electric GV2P20 GV2RT 3-Pole 13-18A Manual Starter and Protector TeSys Deca

Reference No: GV2P20
Rated Current (A): 18
Number of Poles: 3P
99 pcs in stock
$73.76

Schneider Electric GV2P16 GV2RT 3P 9-14A TeSys Deca Manual Starter and Protector

Reference No: GV2P16
Rated Current (A): 14
Number of Poles: 3P
100 pcs in stock
$66.91

Schneider Electric GV2P14 GV2P 3-Pole 6-10A Manual Starter and Protector TeSys Deca

Reference No: GV2P14
Rated Current (A): 10
Number of Poles: 3P
94 pcs in stock
$66.91

Schneider Electric GV2P10 GV2P 3-Pole 4-6.3A TeSys Deca Manual Starter and Protector

Reference No: GV2P10
Rated Current (A): 6.3
Number of Poles: 3P
100 pcs in stock
$60.55

Schneider Electric GV2P08 GV2P 3-Pole 2.5-4A TeSys Deca Manual Starter and Protector

Reference No: GV2P08
Rated Current (A): 4
Number of Poles: 3P
100 pcs in stock
$60.55

Schneider Electric GV2P07 GV2P 3-Pole 1.6-2.5A TeSys Deca Manual Starter and Protector

Reference No: GV2P07
Rated Current (A): 2.5
Number of Poles: 3P
74 pcs in stock
$60.55

Schneider Electric GV2P06 GV2P 3-Pole 1-1.6A TeSys Deca Manual Motor Starter and Protector

Reference No: GV2P06
Rated Current (A): 1.6
Number of Poles: 3P
44 pcs in stock
$60.55

Schneider Electric GV2P05 GV2P 3P 0.63-1A Motor Circuit Breaker TeSys GV2 Series

Reference No: GV2P05
Rated Current (A): 1
Number of Poles: 3P
27 pcs in stock
$59.97

Schneider Electric GV2P04 GV2P 3-Pole 0.40-0.63A TeSys Deca Manual Starter and Protector

Reference No: GV2P04
Rated Current (A): 0.63
Number of Poles: 3P
19 pcs in stock
$59.97

Schneider Electric GV2P03 GV2P 3P 0.25-0.40A TeSys Deca Manual Starter and Protector

Reference No: GV2P03
Rated Current (A): 0.40
Number of Poles: 3P
36 pcs in stock
$59.97

Schneider Electric GV2P02 TeSys Deca GV2P 0.16-0.25 A Manual Starter and Protector

Reference No: GV2P02
Rated Current (A): 0.25
Number of Poles: 3P
0 pcs in stock
$53.83

Schneider Electric GV2ME32 GV2P 3P 24-32A Manual Starter and Protector TeSys Deca

Reference No: GV2ME32
Rated Current (A): 32
Number of Poles: 3P
100 pcs in stock
$119.16

Motor control and protection equipment from ABB, Siemens and Schneider Electric covers everything between the supply and the motor shaft. The range spans contactors, overload relays, motor protection circuit breakers, starters, soft starters, variable frequency drives, servo systems and industrial motors, with rated currents from 0.1 A to 2,650 A and power up to 800 kW. Stoklink ships worldwide from Turkey and quotes project volumes on request.

What's in this range

How to choose

  • Motor power and rated current at the supply voltage. Size the starter or drive for the nameplate current, not just the kW value.
  • Starting method: direct on line, soft start or variable speed. This decides whether you need a contactor, a soft starter or a VFD.
  • Duty class, for example AC-3 for squirrel-cage motors under IEC 60947-4-1.
  • Protection split: overload relay plus fuses or MCB, or a single MPCB.
  • Control interface: coil voltage, fieldbus such as PROFINET, and mounting.

FAQ

What is the difference between a soft starter and a VFD?

A soft starter limits inrush current during start and stop at fixed supply frequency. A VFD changes the output frequency, so it also controls speed while running.

Do I need a contactor and an overload relay, or an MPCB?

An MPCB combines short-circuit and overload protection and works with a contactor. The separate route uses a fuse or MCB, a contactor and an overload relay. Choose by space, coordination type and rating.

Can you ship motor control products outside Turkey?

Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, and project quantities are quoted on request.