Schneider Electric GV2LE22 TeSys Deca GV2LE 25 A Manual Starter and Protector
Schneider Electric GV2LE22 TeSys Deca GV2LE 25 A Manual Starter and Protector
Get Quote
- Description
The Schneider Electric GV2LE22 is a TeSys Deca GV2 manual motor circuit breaker with a fixed magnetic trip unit set for a 25 A line current and a 388.3 A magnetic tripping point. Rated for 690 V AC, it delivers a 15 kA breaking capacity at 400/415 V (dropping to 3 kA at 690 V) and protects motor branches up to 9-11 kW at 400/415 V without a built-in thermal overload function.
Technical Specifications
| Reference | GV2LE22 |
| Brand | Schneider Electric |
| Range | TeSys Deca |
| Product Type | Motor circuit breaker (Manual Starter and Protector) |
| Device Short Name | GV2LE |
| Trip Unit Technology | Magnetic |
| Poles | 3P |
| Line Rated Current [Ith] | 25 A |
| Magnetic Tripping Current | 388.3 A |
| Rated Operational Voltage [Ue] | 690 V AC 50/60 Hz |
| Rated Insulation Voltage [Ui] | 690 V AC |
| Rated Impulse Withstand Voltage [Uimp] | 6 kV |
| Breaking Capacity [Icu] at 400/415 V | 15 kA |
| Breaking Capacity [Icu] at 690 V | 3 kA |
| Motor Power | 9 kW / 11 kW at 400/415 V AC; 11-15 kW at 500 V AC; 18.5 kW at 690 V AC |
| Control Type | Toggle switch |
| Suitability for Isolation | Yes (IEC 60947-1) |
| Power Dissipation per Pole | 1.8 W |
| IP Degree of Protection | IP20 |
| IK Degree of Protection | IK04 |
| Mounting | 35 mm DIN rail or panel with adaptor plate |
| Dimensions (W x H x D) | 45 x 89 x 78.5 mm |
| Net Weight | 0.33 kg |
| Ambient Operating Temperature | -20...60 °C |
| GTIN | 3389110517033 |
Certifications & Standards
- CB Scheme
- CE
- UKCA
- CCC
- cULus
- EAC
- BV
- RINA
- EN/IEC 60947-2
- EN/IEC 60947-4-1
- UL 60947-4-1
- CSA C22.2 No 60947-4-1
- IEC/EN 60335-2-40 Annex JJ
Selection Notes
The magnetic-only trip unit protects against short circuits and locked-rotor surges but carries no thermal overload element, so a separate overload relay or self-protected motor is needed for continuous overload coverage. Breaking capacity falls off sharply with voltage: 15 kA at 400/415 V versus 3 kA at 690 V, so on 690 V feeders it should be backed by upstream fault-current limiting. At 25 A it is the top rating in the GV2LE line covering motors up to 18.5 kW at 690 V; lower-current variants in the same GV2LE range suit smaller motors.
Applications
Used as a motor branch disconnector and short-circuit protector ahead of a contactor in TeSys motor starter combinations for pumps, compressors and conveyor drives on 35 mm DIN rail.