Filter

Molded Case Circuit Breakers (MCCB)

DEMO
Filter
Showing 1 - 700 of 1818 items

Siemens 3VM1080-3ED42-0AA0 3VM1 4P 80A 25kA 415V TM210 LI Molded Case Circuit Breaker

Reference No: 3VM1080-3ED42-0AA0
Catalog No: 3VM1080-3ED42-0AA0
Rated Current (A): 80
Breaking Capacity (kA): 25 kA @415V AC (Icu, class N)
Rated Voltage (VAC): 500 V AC
Number of Poles: 4P
1 pcs in stock
$147.04

Siemens 3VM1112-4ED42-0AA0 3VM1 4P 125A 36kA 415V TM210 LI Molded Case Circuit Breaker

Reference No: 3VM1112-4ED42-0AA0
Catalog No: 3VM1112-4ED42-0AA0
Rated Current (A): 125
Breaking Capacity (kA): 36 kA @415V AC (Icu, class S)
Rated Voltage (VAC): 500 V AC
Number of Poles: 4P
7 pcs in stock
$223.99

Siemens 3VM1116-4ED42-0AA0 3VM1 4P 160A 36kA 415V TM210 LI Molded Case Circuit Breaker

Reference No: 3VM1116-4ED42-0AA0
Catalog No: 3VM1116-4ED42-0AA0
Rated Current (A): 160
Breaking Capacity (kA): 36 kA @415V AC (Icu, class S)
Rated Voltage (VAC): 500 V AC
Number of Poles: 4P
10 pcs in stock
$244.01

Siemens 3VM1132-5MH32-0AA0 3VM1 3P 32A 55kA 415V TM120M I Molded Case Circuit Breaker

Reference No: 3VM1132-5MH32-0AA0
Catalog No: 3VM1132-5MH32-0AA0
Rated Current (A): 32
Breaking Capacity (kA): 55 kA @415V AC (Icu, class M)
Rated Voltage (VAC): 500 V AC
Number of Poles: 3P
0 pcs in stock
$172.02

Siemens 3VM1180-5MH32-0AA0 3VM1 3P 80A 55kA 415V TM120M I Molded Case Circuit Breaker

Reference No: 3VM1180-5MH32-0AA0
Catalog No: 3VM1180-5MH32-0AA0
Rated Current (A): 80
Breaking Capacity (kA): 55 kA @415V AC (Icu, class M)
Rated Voltage (VAC): 500 V AC
Number of Poles: 3P
0 pcs in stock
$152.81

Siemens 3VM1220-4EE42-0AA0 3VM1 4P 200A 36kA 415V TM220 LI Molded Case Circuit Breaker

Reference No: 3VM1220-4EE42-0AA0
Catalog No: 3VM1220-4EE42-0AA0
Rated Current (A): 200
Breaking Capacity (kA): 36 kA @415V AC (Icu, class S)
Rated Voltage (VAC): 500 V AC
Number of Poles: 4P
20 pcs in stock
$386.84

Siemens 3VM1225-3ED32-0AA0 3VM1 3P 250A 25kA 415V TM210 LI Molded Case Circuit Breaker

Reference No: 3VM1225-3ED32-0AA0
Catalog No: 3VM1225-3ED32-0AA0
Rated Current (A): 250
Breaking Capacity (kA): 25 kA @415V AC (Icu, class N)
Rated Voltage (VAC): 500 V AC
Number of Poles: 3P
117 pcs in stock
$258.28

Siemens 3VM1332-5MH32-0AA0 3VM1 3P 320A 55kA 415V TM120M I Molded Case Circuit Breaker

Reference No: 3VM1332-5MH32-0AA0
Catalog No: 3VM1332-5MH32-0AA0
Rated Current (A): 320
Breaking Capacity (kA): 55 kA @415V AC (Icu, class M)
Rated Voltage (VAC): 500 V AC
Number of Poles: 3P
0 pcs in stock
$711.10

Siemens 3VM1450-5MH32-0AA0 3VM1 3P 500A 55kA 415V TM120M I Molded Case Circuit Breaker

Reference No: 3VM1450-5MH32-0AA0
Catalog No: 3VM1450-5MH32-0AA0
Rated Current (A): 500
Breaking Capacity (kA): 55 kA @415V AC (Icu, class M)
Rated Voltage (VAC): 500 V AC
Number of Poles: 3P
0 pcs in stock
$979.19

Siemens 3VA1110-5MH36-0AA0 3VA1 100A 55kA 3-Pole Magnetic Protection Molded Case Circuit Breaker

Reference No: 3VA1110-5MH36-0AA0
Catalog No: 3VA1110-5MH36-0AA0
Rated Current (A): 100
Breaking Capacity (kA): 55 kA
Rated Voltage (VAC): 415 V
Number of Poles: 3P
4 pcs in stock
$238.65

Schneider Electric C12N3TM125B ComPacT NSXm160N 3P 125 A 50 kA TM-D Fixed Moulded Case Circuit Breaker

Reference No: C12N3TM125B
Catalog No: C12N3TM125B
Rated Current (A): 125
Rated Voltage (VAC): 440 V
Number of Poles: 4P
0 pcs in stock
$259.33

Schneider Electric C12F6TM160B ComPacT NSXm160F 4P 160 A 36 kA TM-D Fixed Moulded Case Circuit Breaker

Reference No: C12F6TM160B
Catalog No: C12F6TM160B
Rated Current (A): 160
Rated Voltage (VAC): 440 V
Number of Poles: 4P
0 pcs in stock
$509.16

Schneider Electric C12F6TM125B ComPacT NSXm160F 4P 125 A 36 kA TM-D Fixed Moulded Case Circuit Breaker

Reference No: C12F6TM125B
Catalog No: C12F6TM125B
Rated Current (A): 125
Rated Voltage (VAC): 440 V
Number of Poles: 4P
0 pcs in stock
$435.79

Schneider Electric C12F3TM160B ComPacT NSXm160F 3P 160 A 36 kA TM-D Fixed Moulded Case Circuit Breaker

Reference No: C12F3TM160B
Catalog No: C12F3TM160B
Rated Current (A): 160
Rated Voltage (VAC): 440 V
Number of Poles: 3P
0 pcs in stock
$235.29

Schneider Electric C12B6TM160B ComPacT NSXm 160B 4P 160 A 25 kA TM-D Fixed Moulded Case Circuit Breaker

Reference No: C12B6TM160B
Catalog No: C12B6TM160B
Rated Current (A): 160
Rated Voltage (VAC): 440 V
Number of Poles: 4P
0 pcs in stock
$463.62

Schneider Electric C12B6TM125B ComPacT NSXm 160B 4P 125 A 25 kA TM-D Fixed Moulded Case Circuit Breaker

Reference No: C12B6TM125B
Catalog No: C12B6TM125B
Rated Current (A): 125
Rated Voltage (VAC): 440 V
Number of Poles: 4P
0 pcs in stock
$414.29

Schneider Electric C12B3TM160B ComPacT NSXm 160B 3P 160 A 25 kA TM-D Fixed Moulded Case Circuit Breaker

Reference No: C12B3TM160B
Catalog No: C12B3TM160B
Rated Current (A): 160
Rated Voltage (VAC): 440 V
Number of Poles: 3P
0 pcs in stock
$230.23

Schneider Electric C12B3TM125B ComPacT NSXm 160B 3P 125 A 25 kA TM-D Fixed Moulded Case Circuit Breaker

Reference No: C12B3TM125B
Catalog No: C12B3TM125B
Rated Current (A): 125
Rated Voltage (VAC): 440 V
Number of Poles: 3P
0 pcs in stock
$222.64

Schneider Electric C11N6TM100B ComPacT NSXm 160N 4P 100 A 50 kA TM-D Fixed Moulded Case Circuit Breaker

Reference No: C11N6TM100B
Catalog No: C11N6TM100B
Rated Current (A): 100
Rated Voltage (VAC): 440 V
Number of Poles: 4P
0 pcs in stock
$319.41

Schneider Electric C11N6TM050B ComPacT NSXm 63N 4P 50 A 50 kA TM-D Fixed Moulded Case Circuit Breaker

Reference No: C11N6TM050B
Catalog No: C11N6TM050B
Rated Current (A): 50
Rated Voltage (VAC): 690 V
Number of Poles: 4P
0 pcs in stock
$272.61

Molded case circuit breakers (MCCB) from ABB, Schneider Electric and Siemens protect feeders, motors and distribution boards from about 10 A up to 1600 A. The range covers 3-pole and 4-pole breakers with fixed and adjustable trip units, with more than 1,800 products including accessories. Stoklink ships worldwide from Turkey and quotes project volumes on request.

What's in this range

How to choose

  • Frame size and rated current, with the trip unit set to the load current.
  • Rated breaking capacity (Icu and Ics) at the system voltage, above the prospective short-circuit current.
  • Trip unit: thermal-magnetic for simple feeders, electronic (LSI or LSIG) where selectivity is needed.
  • Poles: 3P or 4P according to the neutral arrangement. Standard: IEC 60947-2.

FAQ

What is the difference between an MCCB and an ACB?

An MCCB is a compact molded-case breaker, typically used from tens of amperes to 1600 A. An ACB is a larger, often draw-out breaker for main incomers from 630 A upward.

What do Icu and Ics mean on an MCCB?

Icu is the ultimate breaking capacity. Ics is the service breaking capacity, the share of Icu after which the breaker stays fit for service.

Do you export MCCBs and their accessories?

Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so request a quote with your part numbers and quantities.