The C12F6TM160B is a 4-pole (3D, neutral unprotected) Schneider Electric ComPacT NSXm160F moulded case circuit breaker rated 160 A, with a TM-D thermal-magnetic trip unit and 36 kA breaking capacity (Icu) at 380/415 V AC. Rated operational voltage (Ue) is 440 V AC. The 108 x 137 x 80 mm frame adds a switched, unprotected neutral pole for 3-phase-plus-neutral distribution circuits.
Technical Specifications
| SKU / Reference | C12F6TM160B |
| Brand | Schneider Electric |
| Range | ComPacT NSXm |
| Device application | Distribution |
| Poles | 4P (3D protected) |
| Neutral protection | No protection (3D, neutral left unprotected) |
| [In] Rated current | 160 A at 40 °C |
| [Ue] Rated operational voltage | 440 V AC 50/60 Hz |
| [Ui] Rated insulation voltage | 800 V AC 50/60 Hz |
| [Uimp] Rated impulse withstand voltage | 8 kV |
| [Icu] Breaking capacity | 85 kA at 220/240 V AC, 36 kA at 380/415 V AC, 35 kA at 440 V AC |
| [Ics] Service breaking capacity | 85 kA at 220/240 V AC, 36 kA at 380/415 V AC, 30 kA at 440 V AC |
| Trip unit | TM-D (thermal-magnetic) |
| Protection functions | LI (long-time overload + instantaneous) |
| [Ir] Long-time pick-up adjustment | 0.7...1 x In, adjustable |
| [Ii] Instantaneous pick-up | 1250 A, fixed |
| Control type | Toggle |
| Mounting mode | Fixed, DIN rail or mounting plate |
| Connection | Front upside, front downside, compression lug/busbar |
| Connection pitch | 35 mm with spreaders, 27 mm without |
| Dimensions (W x H x D) | 108 x 137 x 80 mm |
| Net weight | 1.42 kg |
| IP / IK degree | IP40 / IK07 |
| Pollution degree | 3, conforming to IEC 60664-1 |
| Ambient temperature (operation / storage) | -25…70 °C / -50…85 °C |
Certifications & Standards
- EN/IEC 60947-2
Selection Notes
At 160 A the C12F6TM160B runs the TM-D trip unit at the top of its 0.7...1 x In adjustment band, so the thermal setting can be dialled back if the downstream feeder is sized for less than the full frame current. The 3D pole configuration switches the neutral without protecting it — pick a 4P 4D device elsewhere in the NSX range if the neutral itself needs overload protection. Against the 125 A sibling in the same 36 kA/4P frame, this 160 A unit is the choice when the feeder cable is sized for the higher current.