- Home
- All Collections
- Molded Case Circuit Breakers (MCCB)
Molded Case Circuit Breakers (MCCB)
Siemens 3VA1196-5EE36-0AA0 3VA1 3P 16A 55kA 415V TM220 LI Molded Case Circuit Breaker
Siemens 3VA1450-5EF42-0AA0 3VA1 4P 500A 55kA 415V TM240 LI Molded Case Circuit Breaker
Siemens 3VA2116-5HL42-0AA0 3VA2 4P 160A 55kA 415V ETU320 LI Molded Case Circuit Breaker
Siemens 3VA2116-5KP36-0AA0 3VA2 3P 160A 55kA 415V ETU850 LSI Molded Case Circuit Breaker
Siemens 3VA2125-6KP46-0AA0 3VA2 4P 25A 85kA 415V ETU850 LSI Molded Case Circuit Breaker
Siemens 3VA2163-5HL42-0AA0 3VA2 4P 63A 55kA 415V ETU320 LI Molded Case Circuit Breaker
Siemens 3VA2225-6HL42-0AA0 3VA2 4P 250A 85kA 415V ETU320 LI Molded Case Circuit Breaker
Siemens 3VA2340-4HL42-0AA0 3VA2 4P 400A 36kA 415V ETU320 LI Molded Case Circuit Breaker
Siemens 3VA2450-5KP32-0AA0 3VA2 3P 500A 55kA 415V ETU850 LSI Molded Case Circuit Breaker
Siemens 3VA2450-6KP32-0AA0 3VA2 3P 500A 85kA 415V ETU850 LSI Molded Case Circuit Breaker
Siemens 3VA2463-5KP32-0AA0 3VA2 3P 630A 55kA 415V ETU850 LSI Molded Case Circuit Breaker
Siemens 3VA2463-6HL42-0AA0 3VA2 4P 630A 85kA 415V ETU320 LI Molded Case Circuit Breaker
Siemens 3VA2463-6KP32-0AA0 3VA2 3P 630A 85kA 415V ETU850 LSI Molded Case Circuit Breaker
Siemens 3VA2510-5HL42-0AA0 3VA2 4P 1000A 55kA 415V ETU320 LI Molded Case Circuit Breaker
Siemens 3VA2563-5MN32-0AA0 3VA2 3P 630A 55kA 415V ETU350M LSI Molded Case Circuit Breaker
Siemens 3VA2580-6HL32-0AA0 3VA2 3P 800A 85kA 415V ETU320 LI Molded Case Circuit Breaker
Siemens 3VA2612-6HL42-0AA0 3VA2 4P 1250A 85kA 415V ETU320 LI Molded Case Circuit Breaker
Siemens 3VA2716-1AC13-0AA0 3VA2 4P 1600A 55kA 415V ETU350 LSI Molded Case Circuit Breaker
Siemens 3VA2716-6AB03-0AA0 3VA2 3P 1600A 85kA 415V ETU320 LI Molded Case Circuit Breaker
Siemens 3VM1010-4ED42-0AA0 3VM1 4P 100A 36kA 415V TM210 LI Molded Case Circuit Breaker
Molded case circuit breakers (MCCB) from ABB, Schneider Electric and Siemens protect feeders, motors and distribution boards from about 10 A up to 1600 A. The range covers 3-pole and 4-pole breakers with fixed and adjustable trip units, with more than 1,800 products including accessories. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- ABB Tmax XT MCCBs – XT1 to XT7 frames with thermal-magnetic and Ekip electronic trip units.
- ABB Formula A MCCBs – A1 to A3 frames for general distribution.
- Schneider ComPacT NSX MCCBs – frames from 100 A to 630 A.
- Schneider ComPacT NS MCCBs – breakers from 630 A to 1600 A.
- Schneider GoPact MCCBs – compact breakers up to 800 A.
- Schneider EasyPact CVS MCCBs – CVS100 to CVS630 frames.
- Siemens SENTRON 3VA MCCBs – 3VA1 and 3VA2 breakers up to 1250 A.
- Siemens SENTRON 3VM MCCBs – 3VM1 breakers up to 630 A.
- MCCB Accessories, Releases & Trip Units – releases and trip units.
How to choose
- Frame size and rated current, with the trip unit set to the load current.
- Rated breaking capacity (Icu and Ics) at the system voltage, above the prospective short-circuit current.
- Trip unit: thermal-magnetic for simple feeders, electronic (LSI or LSIG) where selectivity is needed.
- Poles: 3P or 4P according to the neutral arrangement. Standard: IEC 60947-2.
FAQ
What is the difference between an MCCB and an ACB?
An MCCB is a compact molded-case breaker, typically used from tens of amperes to 1600 A. An ACB is a larger, often draw-out breaker for main incomers from 630 A upward.
What do Icu and Ics mean on an MCCB?
Icu is the ultimate breaking capacity. Ics is the service breaking capacity, the share of Icu after which the breaker stays fit for service.
Do you export MCCBs and their accessories?
Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so request a quote with your part numbers and quantities.