Part number
3TF6944-0CM7
Model no
3TF6
$4,399.60 In stock · 16 Dispatch Planned dispatch date. We aim to ship within 1 business day. Depending on warehouse workload it can take 2–3 business days. · From Türkiye
3TF6

Siemens 3TF6944-0CM7 3TF6 630A 3P 400V Contactor

Rated current
630 A
Rated operational voltage
400 V AC
Poles
3P
EAN
4011209044517
Description

About the 3TF6

The Siemens 3TF6944-0CM7 is a contactor from the SENTRON/SIRIUS 3TF6 series. Vacuum contactor AC-3e 630 A, 335 kW / 400 V, AC-3 820 A, 450 kW / 400 V, Ue 690 V, 3-pole, Uc: 200-240 V AC(50/60 Hz) drive: conventional auxiliary contacts 4 NO + 4 NC main circuit: busbar control and auxiliary circuit: screw terminal. Supplied by Stoklink for industrial and commercial low-voltage applications.

Applications & Use Cases

The Siemens 3TF6944-0CM7 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3TF6 range it integrates with compatible SENTRON/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.

Specification

Full specification

174 values · Last verified 29 Oct 2026

General 2

product designation Vacuum contactor
product type designation 3TF6

General technical data 14

size of contactor 14
product extension: function module for communication No
product extension: auxiliary switch No
insulation voltage: of main circuit with degree of pollution 3 rated value 1 000 V
insulation voltage: of auxiliary circuit with degree of pollution 3 rated value 690 V
surge voltage resistance: of main circuit rated value 8 kV
surge voltage resistance: of auxiliary circuit rated value 6 kV
maximum permissible voltage for protective separation: in networks with grounded star point between auxiliary and auxiliary circuit 300 V
shock resistance at rectangular impulse: at AC 9.5 g / 5 ms, 5.7 g / 10 ms
shock resistance with sine pulse: at AC 13.5 g / 5 ms, 7.8 g / 10 ms
mechanical service life (operating cycles): of contactor typical 5 000 000
reference code according to IEC 81346-2 Q
Substance Prohibitance (day/month/year) 03/01/2017
SVHC substance name Lead CAS-No. 7439-92-1 Lead monoxide (lead oxide) CAS-No. 1317-36-8 2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868- 10-5 Melamine CAS-No. 108-78-1

Ambient conditions 6

installation altitude at height above sea level maximum 2 000 m
ambient temperature: during operation -25 ... +55 °C
ambient temperature: during storage -55 ... +80 °C
relative humidity minimum 10 %
relative humidity during operation 10 ... 95 %
relative humidity at 55 °C according to IEC 60068-2-30 maximum 95 %
Show all 174 specifications ↓ Show less ↑152 more values in Identification, Main circuit, Control circuit/ Control, Auxiliary circuit, UL/CSA ratings, Short-circuit protection, Installation/ mounting/ dimensions, Connections/ Terminals, Safety related data, ISO 13849, IEC 61508, Electrical Safety, Logistics.

Identification 10

Part number 3TF6944-0CM7
Type designation 3TF6
Brand Siemens
Condition New, factory sealed
Source Siemens and its authorised distributors
Warranty Manufacturer warranty
Lifecycle status Active, in production
EAN 4011209044517
ETIM class EC000066
eCl@ss 27371003

Main circuit 35

number of poles for main current circuit 3
number of NO contacts for main contacts 3
number of NC contacts for main contacts 0
type of voltage for main current circuit AC
operating voltage: at AC-3 rated value maximum 690 V
operating voltage: at AC-3e rated value maximum 690 V
at AC-1: up to 690 V at ambient temperature 40 °C rated value 910 A
at AC-1: up to 690 V at ambient temperature 55 °C rated value 850 A
at AC-3: at 400 V rated value 820 A
at AC-3: at 500 V rated value 820 A
at AC-3: at 690 V rated value 820 A
at AC-3e: at 400 V rated value 630 A
at AC-3e: at 500 V rated value 630 A
at AC-3e: at 690 V rated value 630 A
at AC-3e: at AC-4 at 400 V rated value 690 A
at AC-6a: up to 500 V for current peak value n=20 rated value 675 A
at AC-6a: up to 690 V for current peak value n=20 rated value 675 A
at AC-6a: up to 400 V for current peak value n=30 rated value 450 A
at AC-6a: up to 500 V for current peak value n=30 rated value 450 A
at AC-6a: up to 690 V for current peak value n=30 rated value 450 A
connectable conductor cross-section in main circuit at AC-1: at 40 °C minimum permissible 600 mm2
operational current for approx. 200000 operating cycles at AC-4: at 400 V rated value 360 A
at AC-3: at 230 V rated value 260 kW
at AC-3e: at 230 V rated value 200 kW
operating apparent power at AC-6a: up to 400 V for current peak value n=20 rated value 445 kVA
operating apparent power at AC-6a: up to 690 V for current peak value n=20 rated value 771 kVA
thermal short-time current limited to 10 s 7 000 A
power loss [W] at AC-3 at 400 V for rated value of the operational current per conductor 70 W
power loss [W] at AC-3e at 400 V for rated value of the operational current per conductor 42 W
no-load switching frequency at AC 500 1/h
operating frequency: at AC-1 maximum 500 1/h
at AC-3e: at 400 V maximum 500 1/h
at AC-3e: at 690 V maximum 500 1/h
at AC-3e: at AC-2 at AC-3 maximum 200 1/h
at AC-3e: at AC-2 at AC-3e maximum 200 1/h

Control circuit/ Control 21

type of voltage of the control supply voltage AC
control supply voltage at AC: at 50 Hz rated value 200 ... 240 V
control supply voltage at AC: at 60 Hz rated value 200 ... 240 V
operating range factor control supply voltage rated value of magnet coil at AC: at 50 Hz 0.8 ... 1.1
inrush current peak 18 A
duration of inrush current peak 300 µs
pickup current mean value 4.5 mA
pickup current peak 5.5 A
duration of pickup current 150 000 µs
holding current mean value 35 mA
at minimum rated control supply voltage at AC: at 50 Hz 900 V·A
at minimum rated control supply voltage at AC: at 60 Hz 900 V·A
at maximum rated control supply voltage at AC: at 60 Hz 1 050 V·A
at maximum rated control supply voltage at AC: at 50 Hz 1 050 V·A
inductive power factor with closing power of the coil: at 50 Hz 1
inductive power factor with closing power of the coil: at 60 Hz 1
inductive power factor with the holding power of the coil: at 50 Hz 0.4
closing delay: at AC 70 ... 120 ms
opening delay: at AC 50 ... 130 ms
arcing time 10 ... 15 ms
control version of the switch operating mechanism Standard A1 - A2

Auxiliary circuit 23

number of NC contacts for auxiliary contacts: attachable 4
number of NC contacts for auxiliary contacts: instantaneous contact 4
number of NO contacts for auxiliary contacts: attachable 4
number of NO contacts for auxiliary contacts: instantaneous contact 4
operational current at AC-12 maximum 10 A
operational current at AC-15: at 230 V rated value 5.6 A
operational current at AC-15: at 400 V rated value 3.6 A
operational current at AC-15: at 500 V rated value 2.5 A
operational current at AC-15: at 690 V rated value 2.3 A
operational current at DC-12 at 440 V rated value 0.33 A
operational current at DC-12: at 24 V rated value 10 A
operational current at DC-12: at 48 V rated value 10 A
operational current at DC-12: at 110 V rated value 3.2 A
operational current at DC-12: at 125 V rated value 2.5 A
operational current at DC-12: at 220 V rated value 0.9 A
operational current at DC-12: at 600 V rated value 0.22 A
operational current at DC-13: at 24 V rated value 10 A
operational current at DC-13: at 48 V rated value 5 A
operational current at DC-13: at 110 V rated value 1.14 A
operational current at DC-13: at 125 V rated value 0.98 A
operational current at DC-13: at 220 V rated value 0.48 A
operational current at DC-13: at 600 V rated value 0.07 A
contact reliability of auxiliary contacts one incorrect switching operation of 100 million switching operations (17 V, 5 mA)

UL/CSA ratings 7

full-load current (FLA) for 3-phase AC motor: at 480 V rated value 820 A
full-load current (FLA) for 3-phase AC motor: at 600 V rated value 820 A
for 3-phase AC motor: at 200/208 V rated value 290 hp
for 3-phase AC motor: at 220/230 V rated value 350 hp
for 3-phase AC motor: at 460/480 V rated value 700 hp
for 3-phase AC motor: at 575/600 V rated value 860 hp
contact rating of auxiliary contacts according to UL A600 / Q600

Short-circuit protection 2

for short-circuit protection of the main circuit: with type of coordination 1 required gG: 1250 A (690 V, 100 kA)
for short-circuit protection of the main circuit: for short-circuit protection of the auxiliary switch required fuse gG: 10 A

Installation/ mounting/ dimensions 18

mounting position with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
fastening method side-by-side mounting Yes
fastening method screw fixing
height 295 mm
width 230 mm
depth 237 mm
with side-by-side mounting: forwards 20 mm
with side-by-side mounting: upwards 10 mm
with side-by-side mounting: downwards 10 mm
with side-by-side mounting: at the side 10 mm
for grounded parts: forwards 20 mm
for grounded parts: upwards 10 mm
for grounded parts: at the side 10 mm
for grounded parts: downwards 10 mm
for live parts: forwards 20 mm
for live parts: upwards 10 mm
for live parts: downwards 10 mm
for live parts: at the side 10 mm

Connections/ Terminals 15

type of electrical connection: for main current circuit Connection bar
type of electrical connection: for auxiliary and control circuit screw-type terminals
type of electrical connection: at contactor for auxiliary contacts Screw-type terminals
width of connection bar 40 mm
thickness of connection bar 6 mm
diameter of holes 13.5 mm
number of holes 1
type of connectable conductor cross-sections for main contacts: stranded 50 ... 240 mm2
connectable conductor cross-section for main contacts: finely stranded with core end processing 240 ... 50 mm2
connectable conductor cross-section for auxiliary contacts: solid or stranded 0.5 ... 2.5 mm2
connectable conductor cross-section for auxiliary contacts: finely stranded with core end processing 0.5 ... 2.5 mm2
for auxiliary contacts: solid 2x (0.5 ... 1.0 mm2), 2x (1.0 ... 2.5 mm2)
for auxiliary contacts: finely stranded with core end processing 2x (0.5 ... 1.0 mm2), 2x (0.75 ... 2.5 mm2)
for auxiliary contacts: for AWG cables for auxiliary contacts 2x (18 ... 12)
AWG number as coded connectable conductor cross section for main contacts 500

ISO 13849 2

device type according to ISO 13849-1 3
overdimensioning according to ISO 13849-2 necessary Yes

IEC 61508 1

safety device type according to IEC 61508-2 Type A

Electrical Safety 2

protection class IP on the front according to IEC 60529 IP00; IP20 with cover
touch protection on the front according to IEC 60529 finger-safe, for vertical contact from the front with cover

Logistics 7

Net weight 22.202 kg
Package dimensions 404 × 374 × 378 mm
Country of origin Turkiye
Shipping weight 24.202 kg
Ships from Türkiye
Dispatch 18 Nov
Stock In stock

Source: manufacturer data · Last verified: 29 Oct 2026

Documents

Documents for 3TF6944-0CM7

No documents are on file for this part yet.

Ask us for the datasheet
Quick answers

Questions about the 3TF6

What is the rated current of 3TF6?

The rated current of 3TF6 is 630 A.

Which supply voltage is 3TF6 rated for?

The rated operational voltage of 3TF6 is 400 V AC.

What is the EAN of 3TF6?

The EAN (GTIN) of 3TF6 is 4011209044517.

Where does 3TF6 ship from, and how fast?

3TF6 ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival. Stock items are dispatched within 1–2 business days.

Guides

Guides for contactors

All guides for contactors
Reviews

Customer reviews

Series

Siemens 3TF6

Brand
Siemens
Series
3TF6
Series

Other series in Contactors

$4,399.60 In stock · 18 Nov
Quote

Get a Quote

3TF6

Genuine parts

Genuine, factory-sealed parts

Siemens · 3TF6944-0CM7

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
Siemens and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.

Added to cart Could not add to cart