Part number
3RT2636-1AP03
Model no
3RT26
$279.16 In stock · 50+ Dispatch Planned dispatch date. We aim to ship within 1 business day. Depending on warehouse workload it can take 2–3 business days. · From Türkiye

Siemens 3RT2636-1AP03 3RT2 72.2A 3P 400V Contactor

Rated current
72.2 A
Rated operational voltage
400 V AC
Poles
3P
EAN
4011209953499
Description

About the 3RT26

The Siemens 3RT2636-1AP03 is a contactor from the SENTRON/SIRIUS 3RT2 series. Capacitor contactor, AC-6b 50 kVAr, / 400 V, 3-pole, 230 V AC, 50 Hz, auxiliary contacts: 1 NO + 1 NC, screw terminal, size: S2. Supplied by Stoklink for industrial and commercial low-voltage applications.

Certifications & Standards

  • EN 50022

Applications & Use Cases

The Siemens 3RT2636-1AP03 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RT2 range it integrates with compatible SENTRON/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.

Specification

Full specification

110 values · Last verified 29 Oct 2026

General 3

product brand name SIRIUS
product designation capacitor contactors
product type designation 3RT26

General technical data 16

size of contactor S2
product extension auxiliary switch Yes
power loss [W] for rated value of the current: at AC in hot operating state per pole 4 W
power loss [W] for rated value of the current: without load current share typical 6 W
type of calculation of power loss current-dependent quadratic
insulation voltage: of main circuit with degree of pollution 3 rated value 690 V
insulation voltage: of auxiliary circuit with degree of pollution 3 rated value 690 V
surge voltage resistance: of main circuit rated value 6 kV
surge voltage resistance: of auxiliary circuit rated value 6 kV
maximum permissible voltage for protective separation between coil and main contacts according to EN 60947-1 400 V
shock resistance at rectangular impulse: at AC 6.8 g / 5 ms, 4 g / 10 ms
shock resistance with sine pulse: at AC 10.6 g / 5 ms, 6.2 g / 10 ms
mechanical service life (operating cycles): of the contactor with added auxiliary switch block typical 3 000 000
electrical endurance (operating cycles) 200 000
reference code according to IEC 81346-2 Q
Substance Prohibitance (day/month/year) 05/01/2014

Ambient conditions 5

installation altitude at height above sea level maximum 2 000 m
ambient temperature: during operation -25 ... +60 °C
ambient temperature: during storage -55 ... +80 °C
relative humidity minimum 10 %
relative humidity at 55 °C according to IEC 60068-2-30 maximum 95 %
Show all 110 specifications ↓ Show less ↑86 more values in Identification, Main circuit, Control circuit/ Control, Auxiliary circuit, UL/CSA ratings, Short-circuit protection, Installation/ mounting/ dimensions, Connections/ Terminals, Safety related data, Electrical Safety, Approvals Certificates, Logistics.

Identification 10

Part number 3RT2636-1AP03
Type designation 3RT26
Brand Siemens
Condition New, factory sealed
Source Siemens and its authorised distributors
Warranty Manufacturer warranty
Lifecycle status Active, in production
EAN 4011209953499
ETIM class EC001079
eCl@ss 27371006

Main circuit 16

number of poles for main current circuit 3
number of NO contacts for main contacts 3
number of NC contacts for main contacts 0
operational current at AC-6b at 690 V at ambient temperature 60 °C rated value 72.2 A
operating reactive power at AC-6b: at 230 V at 50/60 Hz at ambient temperature 60 °C rated value 10 ... 29 kvar
operating reactive power at AC-6b: at 400 V at 50/60 Hz at ambient temperature 60 °C rated value 17 ... 50 kvar
operating reactive power at AC-6b: at 500 V at 50/60 Hz at ambient temperature 60 °C rated value 21 ... 63 kvar
operating reactive power at AC-6b: at 690 V at 50/60 Hz at ambient temperature 60 °C rated value 29 ... 86 kvar
no-load switching frequency: at AC 500 1/h
operating frequency at AC-6b: at 230 V maximum 100 1/h
operating frequency at AC-6b: at 240 V maximum 100 1/h
operating frequency at AC-6b: at 400 V maximum 100 1/h
operating frequency at AC-6b: at 480 V maximum 60 1/h
operating frequency at AC-6b: at 500 V maximum 55 1/h
operating frequency at AC-6b: at 600 V maximum 40 1/h
operating frequency at AC-6b: at 690 V maximum 30 1/h

Control circuit/ Control 13

type of voltage AC
type of voltage of the control supply voltage AC
control supply voltage at AC: at 50 Hz rated value 230 V
control supply voltage frequency: 1 rated value 50 Hz
operating range factor control supply voltage rated value of magnet coil at AC: at 50 Hz 0.8 ... 1.1
apparent pick-up power of magnet coil at AC 190 V·A
inductive power factor with closing power of the coil 0.72
apparent holding power of magnet coil at AC 16 V·A
inductive power factor with the holding power of the coil 0.37
closing delay: at AC 10 ... 80 ms
opening delay: at AC 10 ... 18 ms
arcing time 10 ... 20 ms
control version of the switch operating mechanism Standard A1 - A2

Auxiliary circuit 14

number of NC contacts for auxiliary contacts 1
attachable 1
instantaneous contact 1
number of NO contacts for auxiliary contacts 1
operational current of auxiliary contacts at AC-12 maximum 10 A
operational current of auxiliary contacts at AC-15: at 230 V 6 A
operational current of auxiliary contacts at AC-15: at 400 V 3 A
operational current of auxiliary contacts at AC-15: at 690 V 0 A
operational current of auxiliary contacts at DC-13: at 24 V 6 A
operational current of auxiliary contacts at DC-13: at 60 V 2 A
operational current of auxiliary contacts at DC-13: at 110 V 1 A
operational current of auxiliary contacts at DC-13: at 125 V 0.9 A
operational current of auxiliary contacts at DC-13: at 220 V 0.3 A
contact reliability of auxiliary contacts 0.00000001

UL/CSA ratings 1

contact rating of auxiliary contacts according to UL A600 / Q600

Short-circuit protection 2

design of the miniature circuit breaker for short-circuit protection of the auxiliary circuit up to 230 V C characteristic: 10 A; 0.4 kA
design of the fuse link: for short-circuit protection of the main circuit with type of coordination 1 required gG: 160 A (690 V, 50 kA)

Installation/ mounting/ dimensions 7

mounting position +/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface
fastening method screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 50022
height 114 mm
width 65 mm
depth 130 mm
required spacing: with side-by-side mounting at the side 10 mm
required spacing: for grounded parts at the side 10 mm

Connections/ Terminals 11

type of electrical connection: for main current circuit screw-type terminals
type of electrical connection: for auxiliary and control circuit screw-type terminals
type of electrical connection: at contactor for auxiliary contacts Screw-type terminals
type of electrical connection: of magnet coil screw terminal
type of connectable conductor cross-sections for main contacts: solid 2x (1 ... 16 mm2)
for auxiliary contacts: solid 2x (0.5 ... 1.5 mm2), 2x (0.75 ... 2.5 mm2), 2x 4 mm2
for auxiliary contacts: solid or stranded 2x (0.5 ... 1.5 mm2), 2x (0.75 ... 2.5 mm2), 2x 4 mm2
for auxiliary contacts: finely stranded with core end processing 2x (0.5 ... 1.5 mm2), 2x (0.75 ... 2.5 mm2)
for auxiliary contacts: for AWG cables for auxiliary contacts 2x (20 ... 16), 2x (18 ... 14), 2x 12
type of minimum connectable cross-sections for main contacts at AC-6b: at 40 °C 1x 35 mm2
AWG number as coded connectable conductor cross section for main contacts 18 ... 0

Electrical Safety 2

protection class IP on the front according to IEC 60529 IP20
touch protection on the front according to IEC 60529 finger-safe, for vertical contact from the front

Approvals Certificates 1

Environmental Product Declaration: global warming potential [CO2 eq] / during manufacturing 2.47 kg

Logistics 7

Net weight 1.005 kg
Package dimensions 121 × 84 × 148 mm
Country of origin DE
Shipping weight 1.505 kg
Ships from Türkiye
Dispatch 13 Nov
Stock In stock

Source: manufacturer data · Last verified: 29 Oct 2026

Documents

Documents for 3RT2636-1AP03

No documents are on file for this part yet.

Ask us for the datasheet
Certifications

Certifications and standards

  • EN 50022
Quick answers

Questions about the 3RT26

What is the rated current of 3RT26?

The rated current of 3RT26 is 72.2 A.

Which supply voltage is 3RT26 rated for?

The rated operational voltage of 3RT26 is 400 V AC.

What is the EAN of 3RT26?

The EAN (GTIN) of 3RT26 is 4011209953499.

Where does 3RT26 ship from, and how fast?

3RT26 ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival. Stock items are dispatched within 1–2 business days.

Guides

Guides for contactors

All guides for contactors
Reviews

Customer reviews

Series

Siemens Siemens 3RT2

Brand
Siemens
Series
Siemens 3RT2
Series page →
Series

Other series in Contactors

$279.16 In stock · 13 Nov
Quote

Get a Quote

3RT26

Genuine parts

Genuine, factory-sealed parts

Siemens · 3RT2636-1AP03

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
Siemens and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.

Added to cart Could not add to cart