Contactors for Data Center PDU and UPS Systems: Selection Guide
AC-1 and AC-6a contactors for data center PDU and UPS systems: sizing, harmonic derating, coil selection, and endurance guidance for engineers. Shop at Stoklink.
The Siemens 3TF6844-0CM7 is a contactor from the SENTRON/SIRIUS 3TF6 series. Vacuum contactor AC-3e/AC-3 630 A, 335 kW / 400 V, Ue 690 V, 3-pole, Uc: 200-240 V AC(50/60 Hz) drive: conventional auxiliary contacts 4 NO + 4 NC main circuit: busbar control and auxiliary circuit: screw terminal. Supplied by Stoklink for industrial and commercial low-voltage applications.
The Siemens 3TF6844-0CM7 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3TF6 range it integrates with compatible SENTRON/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.
| product designation | Vacuum contactor |
|---|---|
| product type designation | 3TF6 |
| size of contactor | 14 |
|---|---|
| product extension: function module for communication | No |
| product extension: auxiliary switch | No |
| insulation voltage: of main circuit with degree of pollution 3 rated value | 1 000 V |
| insulation voltage: of auxiliary circuit with degree of pollution 3 rated value | 690 V |
| surge voltage resistance: of main circuit rated value | 8 kV |
| surge voltage resistance: of auxiliary circuit rated value | 6 kV |
| maximum permissible voltage for protective separation: in networks with grounded star point between auxiliary and auxiliary circuit | 300 V |
| shock resistance at rectangular impulse: at AC | 8.1 g / 5 ms, 4.7 g / 10 ms |
| shock resistance with sine pulse: at AC | 12.8 g / 5 ms, 7.4 g / 10 ms |
| mechanical service life (operating cycles): of contactor typical | 5 000 000 |
| reference code according to IEC 81346-2 | Q |
| Substance Prohibitance (day/month/year) | 03/01/2017 |
| SVHC substance name | Lead CAS-No. 7439-92-1 Lead monoxide (lead oxide) CAS-No. 1317-36-8 2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868- 10-5 Melamine CAS-No. 108-78-1 |
| installation altitude at height above sea level maximum | 2 000 m |
|---|---|
| ambient temperature: during operation | -25 ... +55 °C |
| ambient temperature: during storage | -55 ... +80 °C |
| relative humidity minimum | 10 % |
| relative humidity during operation | 10 ... 95 % |
| relative humidity at 55 °C according to IEC 60068-2-30 maximum | 95 % |
| Part number | 3TF6844-0CM7 |
|---|---|
| Type designation | 3TF6 |
| Brand | Siemens |
| Condition | New, factory sealed |
| Source | Siemens and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 4011209044463 |
| ETIM class | EC000066 |
| eCl@ss | 27371003 |
| number of poles for main current circuit | 3 |
|---|---|
| number of NO contacts for main contacts | 3 |
| number of NC contacts for main contacts | 0 |
| type of voltage for main current circuit | AC |
| operating voltage: at AC-3 rated value maximum | 690 V |
| operating voltage: at AC-3e rated value maximum | 690 V |
| at AC-1: up to 690 V at ambient temperature 40 °C rated value | 700 A |
| at AC-1: up to 690 V at ambient temperature 55 °C rated value | 630 A |
| at AC-3: at 400 V rated value | 630 A |
| at AC-3: at 500 V rated value | 630 A |
| at AC-3: at 690 V rated value | 630 A |
| at AC-3e: at 400 V rated value | 552 A |
| at AC-3e: at 500 V rated value | 552 A |
| at AC-3e: at 690 V rated value | 552 A |
| at AC-3e: at AC-4 at 400 V rated value | 610 A |
| at AC-6a: up to 500 V for current peak value n=20 rated value | 513 A |
| at AC-6a: up to 690 V for current peak value n=20 rated value | 513 A |
| at AC-6a: up to 400 V for current peak value n=30 rated value | 342 A |
| at AC-6a: up to 500 V for current peak value n=30 rated value | 342 A |
| at AC-6a: up to 690 V for current peak value n=30 rated value | 342 A |
| connectable conductor cross-section in main circuit at AC-1: at 40 °C minimum permissible | 480 mm2 |
| operational current for approx. 200000 operating cycles at AC-4: at 400 V rated value | 300 A |
| at AC-3: at 230 V rated value | 200 kW |
| at AC-3e: at 230 V rated value | 160 kW |
| operating apparent power at AC-6a: up to 400 V for current peak value n=20 rated value | 338 kVA |
| operating apparent power at AC-6a: up to 690 V for current peak value n=20 rated value | 586 kVA |
| thermal short-time current limited to 10 s | 5 040 A |
| power loss [W] at AC-3 at 400 V for rated value of the operational current per conductor | 45 W |
| power loss [W] at AC-3e at 400 V for rated value of the operational current per conductor | 35 W |
| no-load switching frequency at AC | 500 1/h |
| operating frequency: at AC-1 maximum | 500 1/h |
| at AC-3e: at 400 V maximum | 500 1/h |
| at AC-3e: at 690 V maximum | 500 1/h |
| at AC-3e: at AC-2 at AC-3 maximum | 200 1/h |
| at AC-3e: at AC-2 at AC-3e maximum | 200 1/h |
| type of voltage of the control supply voltage | AC |
|---|---|
| control supply voltage at AC: at 50 Hz rated value | 200 ... 240 V |
| control supply voltage at AC: at 60 Hz rated value | 200 ... 240 V |
| operating range factor control supply voltage rated value of magnet coil at AC: at 50 Hz | 0.8 ... 1.1 |
| inrush current peak | 18 A |
| duration of inrush current peak | 300 µs |
| pickup current mean value | 4.3 mA |
| pickup current peak | 5 A |
| duration of pickup current | 150 000 µs |
| holding current mean value | 35 mA |
| at minimum rated control supply voltage at AC: at 50 Hz | 850 V·A |
| at minimum rated control supply voltage at AC: at 60 Hz | 850 V·A |
| at maximum rated control supply voltage at AC: at 60 Hz | 950 V·A |
| at maximum rated control supply voltage at AC: at 50 Hz | 950 V·A |
| inductive power factor with closing power of the coil: at 50 Hz | 1 |
| inductive power factor with closing power of the coil: at 60 Hz | 1 |
| inductive power factor with the holding power of the coil: at 50 Hz | 0.4 |
| closing delay: at AC | 70 ... 120 ms |
| opening delay: at AC | 50 ... 130 ms |
| arcing time | 10 ... 15 ms |
| control version of the switch operating mechanism | Standard A1 - A2 |
| number of NC contacts for auxiliary contacts: attachable | 4 |
|---|---|
| number of NC contacts for auxiliary contacts: instantaneous contact | 4 |
| number of NO contacts for auxiliary contacts: attachable | 4 |
| number of NO contacts for auxiliary contacts: instantaneous contact | 4 |
| operational current at AC-12 maximum | 10 A |
| operational current at AC-15: at 230 V rated value | 5.6 A |
| operational current at AC-15: at 400 V rated value | 3.6 A |
| operational current at AC-15: at 500 V rated value | 2.5 A |
| operational current at AC-15: at 690 V rated value | 2.3 A |
| operational current at DC-12 at 440 V rated value | 0.33 A |
| operational current at DC-12: at 24 V rated value | 10 A |
| operational current at DC-12: at 48 V rated value | 10 A |
| operational current at DC-12: at 110 V rated value | 3.2 A |
| operational current at DC-12: at 125 V rated value | 2.5 A |
| operational current at DC-12: at 220 V rated value | 0.9 A |
| operational current at DC-12: at 600 V rated value | 0.22 A |
| operational current at DC-13: at 24 V rated value | 10 A |
| operational current at DC-13: at 48 V rated value | 5 A |
| operational current at DC-13: at 110 V rated value | 1.14 A |
| operational current at DC-13: at 125 V rated value | 0.98 A |
| operational current at DC-13: at 220 V rated value | 0.48 A |
| operational current at DC-13: at 600 V rated value | 0.07 A |
| contact reliability of auxiliary contacts | one incorrect switching operation of 100 million switching operations (17 V, 5 mA) |
| full-load current (FLA) for 3-phase AC motor: at 480 V rated value | 630 A |
|---|---|
| full-load current (FLA) for 3-phase AC motor: at 600 V rated value | 630 A |
| for 3-phase AC motor: at 200/208 V rated value | 231 hp |
| for 3-phase AC motor: at 220/230 V rated value | 266 hp |
| for 3-phase AC motor: at 460/480 V rated value | 530 hp |
| for 3-phase AC motor: at 575/600 V rated value | 664 hp |
| contact rating of auxiliary contacts according to UL | A600 / Q600 |
| for short-circuit protection of the main circuit: with type of coordination 1 required | gG: 1000 A (690 V, 100 kA) |
|---|---|
| for short-circuit protection of the main circuit: for short-circuit protection of the auxiliary switch required | fuse gG: 10 A |
| mounting position | with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back |
|---|---|
| fastening method side-by-side mounting | Yes |
| fastening method | screw fixing |
| height | 276 mm |
| width | 230 mm |
| depth | 237 mm |
| with side-by-side mounting: forwards | 20 mm |
| with side-by-side mounting: upwards | 10 mm |
| with side-by-side mounting: downwards | 10 mm |
| with side-by-side mounting: at the side | 10 mm |
| for grounded parts: forwards | 20 mm |
| for grounded parts: upwards | 10 mm |
| for grounded parts: at the side | 10 mm |
| for grounded parts: downwards | 10 mm |
| for live parts: forwards | 20 mm |
| for live parts: upwards | 10 mm |
| for live parts: downwards | 10 mm |
| for live parts: at the side | 10 mm |
| type of electrical connection: for main current circuit | Connection bar |
|---|---|
| type of electrical connection: for auxiliary and control circuit | screw-type terminals |
| type of electrical connection: at contactor for auxiliary contacts | Screw-type terminals |
| width of connection bar | 30 mm |
| thickness of connection bar | 6 mm |
| diameter of holes | 11 mm |
| number of holes | 1 |
| type of connectable conductor cross-sections for main contacts: stranded | 70 ... 240 mm2 |
| connectable conductor cross-section for main contacts: finely stranded with core end processing | 240 ... 50 mm2 |
| connectable conductor cross-section for auxiliary contacts: solid or stranded | 0.5 ... 2.5 mm2 |
| connectable conductor cross-section for auxiliary contacts: finely stranded with core end processing | 0.5 ... 2.5 mm2 |
| for auxiliary contacts: solid | 2x (0.5 ... 1.0 mm2), 2x (1.0 ... 2.5 mm2) |
| for auxiliary contacts: finely stranded with core end processing | 2x (0.5 ... 1.0 mm2), 2x (0.75 ... 2.5 mm2) |
| for auxiliary contacts: for AWG cables for auxiliary contacts | 2x (18 ... 12) |
| AWG number as coded connectable conductor cross section for main contacts | 500 |
| device type according to ISO 13849-1 | 3 |
|---|---|
| overdimensioning according to ISO 13849-2 necessary | Yes |
| safety device type according to IEC 61508-2 | Type A |
|---|
| protection class IP on the front according to IEC 60529 | IP00; IP20 with cover |
|---|---|
| touch protection on the front according to IEC 60529 | finger-safe, for vertical contact from the front with cover |
| Net weight | 19.24 kg |
|---|---|
| Package dimensions | 390 × 375 × 380 mm |
| Country of origin | Turkiye |
| Shipping weight | 21.24 kg |
| Ships from | Türkiye |
| Dispatch | 18 Nov |
| Stock | In stock |
Source: manufacturer data · Last verified: 29 Oct 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated current of 3TF6 is 630 A.
The rated operational voltage of 3TF6 is 400 V AC.
The EAN (GTIN) of 3TF6 is 4011209044463.
3TF6 ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival. Stock items are dispatched within 1–2 business days.
AC-1 and AC-6a contactors for data center PDU and UPS systems: sizing, harmonic derating, coil selection, and endurance guidance for engineers. Shop at Stoklink.
Compare AC3 rating IEC contactors versus NEMA size codes, with cross-reference tables, derating formulas, and selection tips for engineers. Shop at Stoklink.
Master AC3 rating selection with our complete contactor checklist covering load sizing, utilization categories, derating, and coordination. Shop at Stoklink.