Siemens 3RT2316-1AP00 3RT2 18A 4P 400V Contactor

Rated current
18 A
Rated operational voltage
400 V AC
Poles
4P
EAN
4011209845589
Other ratings in Siemens 3RT2 All 9 ratings ↓
Neighbouring ratings in the same series
Motor power kW Rated current In (A) Part number Stock Price
18 3RT2316-1AP00This part In stock $31.22
22 3RT2317-1AP00 In stock $34.78
35 3RT2325-1AP00 In stock $54.80
40 3RT2326-1AP00 In stock $77.23
50 3RT2327-1AP00 In stock $120.46
Description

About the 3RT23

The Siemens 3RT2316-1AP00 is a contactor from the SENTRON/SIRIUS 3RT2 series. Contactor AC-1, 18 A, 400 V / 40 °C, 4-pole, 230 V AC, 50/60 Hz, screw terminal, size: S00. Supplied by Stoklink for industrial and commercial low-voltage applications.

Certifications & Standards

  • EN 60715

Applications & Use Cases

The Siemens 3RT2316-1AP00 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3RT2 range it integrates with compatible SENTRON/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.

Specification

Full specification

142 values · Last verified 29 Oct 2026

General 3

product brand name SIRIUS
product designation Contactor
product type designation 3RT23

General technical data 16

size of contactor S00
product extension: function module for communication No
product extension: auxiliary switch Yes
power loss [W] for rated value of the current: at AC in hot operating state 4.4 W
power loss [W] for rated value of the current: without load current share typical 1.1 W
type of calculation of power loss current-dependent quadratic
insulation voltage: of main circuit with degree of pollution 3 rated value 690 V
insulation voltage: of the auxiliary and control circuit with degree of pollution 3 rated value 690 V
surge voltage resistance: of main circuit rated value 6 kV
surge voltage resistance: of auxiliary circuit rated value 6 kV
shock resistance at rectangular impulse: at AC 6,7 g / 5 ms, 4,2 g / 10 ms
shock resistance with sine pulse: at AC 10,5 g / 5 ms, 6,6 g / 10 ms
mechanical service life (operating cycles): of contactor typical 30 000 000
mechanical service life (operating cycles): of the contactor with added auxiliary switch block typical 10 000 000
reference code according to IEC 81346-2 Q
Substance Prohibitance (day/month/year) 10/01/2009

Ambient conditions 5

installation altitude at height above sea level maximum 2 000 m
ambient temperature: during operation -25 ... +60 °C
ambient temperature: during storage -55 ... +80 °C
relative humidity minimum 10 %
relative humidity at 55 °C according to IEC 60068-2-30 maximum 95 %
Show all 142 specifications ↓ Show less ↑118 more values in Identification, Main circuit, Control circuit/ Control, Auxiliary circuit, Short-circuit protection, Installation/ mounting/ dimensions, Connections/ Terminals, Safety related data, Electrical Safety, Communication/ Protocol, Approvals Certificates, Logistics.

Identification 10

Part number 3RT2316-1AP00
Type designation 3RT23
Brand Siemens
Condition New, factory sealed
Source Siemens and its authorised distributors
Warranty Manufacturer warranty
Lifecycle status Active, in production
EAN 4011209845589
ETIM class EC000066
eCl@ss 27371003

Main circuit 39

number of poles for main current circuit 4
number of NO contacts for main contacts 4
type of voltage for main current circuit AC
operational current: at AC-1 at 400 V at ambient temperature 40 °C rated value 18 A
at AC-1: up to 690 V at ambient temperature 40 °C rated value 18 A
at AC-1: up to 690 V at ambient temperature 60 °C rated value 16 A
at AC-3: at 400 V rated value 9 A
at AC-3: at AC-4 at 400 V rated value 8.5 A
minimum cross-section in main circuit at maximum AC-1 rated value 2.5 mm2
at 1 current path at DC-1: at 24 V rated value 16 A
at 1 current path at DC-1: at 60 V rated value 16 A
at 1 current path at DC-1: at 110 V rated value 2.1 A
at 1 current path at DC-1: at 220 V rated value 0.8 A
at 1 current path at DC-1: at 440 V rated value 0.6 A
with 2 current paths in series at DC-1: at 24 V rated value 16 A
with 2 current paths in series at DC-1: at 60 V rated value 16 A
with 2 current paths in series at DC-1: at 110 V rated value 12 A
with 2 current paths in series at DC-1: at 220 V rated value 1.6 A
with 2 current paths in series at DC-1: at 440 V rated value 0.8 A
with 3 current paths in series at DC-1: at 24 V rated value 16 A
with 3 current paths in series at DC-1: at 60 V rated value 16 A
with 3 current paths in series at DC-1: at 110 V rated value 16 A
with 3 current paths in series at DC-1: at 220 V rated value 16 A
with 3 current paths in series at DC-1: at 440 V rated value 1.3 A
at 1 current path at DC-3 at DC-5: at 24 V rated value 16 A
at 1 current path at DC-3 at DC-5: at 60 V rated value 0.5 A
at 1 current path at DC-3 at DC-5: at 110 V rated value 0.15 A
with 2 current paths in series at DC-3 at DC-5: at 24 V rated value 16 A
with 2 current paths in series at DC-3 at DC-5: at 60 V rated value 5 A
with 2 current paths in series at DC-3 at DC-5: at 110 V rated value 0.35 A
with 3 current paths in series at DC-3 at DC-5: at 24 V rated value 16 A
with 3 current paths in series at DC-3 at DC-5: at 60 V rated value 16 A
with 3 current paths in series at DC-3 at DC-5: at 110 V rated value 16 A
with 3 current paths in series at DC-3 at DC-5: at 220 V rated value 1.5 A
with 3 current paths in series at DC-3 at DC-5: at 440 V rated value 0.2 A
operating power: at AC-3 at 400 V rated value 4 kW
operating power: at AC-4 at 400 V rated value 4 kW
no-load switching frequency: at AC 10 000 1/h
operating frequency: at AC-1 maximum 1 000 1/h

Control circuit/ Control 16

type of voltage AC
type of voltage of the control supply voltage AC
control supply voltage at AC: at 50 Hz rated value 230 V
control supply voltage at AC: at 60 Hz rated value 230 V
operating range factor control supply voltage rated value of magnet coil at AC: at 50 Hz 0.8 ... 1.1
apparent pick-up power of magnet coil at AC: at 50 Hz 27 V·A
apparent pick-up power of magnet coil at AC: at 60 Hz 24.3 V·A
inductive power factor with closing power of the coil: at 50 Hz 0.8
inductive power factor with closing power of the coil: at 60 Hz 0.75
apparent holding power of magnet coil at AC: at 50 Hz 4.2 V·A
apparent holding power of magnet coil at AC: at 60 Hz 3.3 V·A
inductive power factor with the holding power of the coil: at 50 Hz 0.25
closing delay: at AC 9 ... 35 ms
opening delay: at AC 7 ... 13 ms
arcing time 10 ... 15 ms
control version of the switch operating mechanism Standard A1 - A2

Auxiliary circuit 2

number of NC contacts for auxiliary contacts: attachable 2
number of NO contacts for auxiliary contacts: attachable 2

Short-circuit protection 1

for short-circuit protection of the main circuit: with type of coordination 1 required gG: 35 A (690 V, 100 kA)

Installation/ mounting/ dimensions 18

mounting position +/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface
fastening method side-by-side mounting Yes
fastening method screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
height 58 mm
width 45 mm
depth 73 mm
with side-by-side mounting: forwards 10 mm
with side-by-side mounting: upwards 10 mm
with side-by-side mounting: downwards 10 mm
with side-by-side mounting: at the side 0 mm
for grounded parts: forwards 10 mm
for grounded parts: upwards 10 mm
for grounded parts: at the side 6 mm
for grounded parts: downwards 10 mm
for live parts: forwards 10 mm
for live parts: upwards 10 mm
for live parts: downwards 10 mm
for live parts: at the side 6 mm

Connections/ Terminals 19

type of electrical connection: for main current circuit screw-type terminals
type of electrical connection: for auxiliary and control circuit screw-type terminals
type of electrical connection: at contactor for auxiliary contacts Screw-type terminals
type of electrical connection: of magnet coil screw terminal
for main contacts: solid 2x (0.5 ... 1.5 mm2), 2x (0.75 ... 2.5 mm2), 2x 4 mm2
for main contacts: solid or stranded 2x (0,5 ... 1,5 mm2), 2x (0,75 ... 2,5 mm2), 2x 4 mm2
for main contacts: finely stranded with core end processing 2x (0.5 ... 1.5 mm2), 2x (0.75 ... 2.5 mm2)
for main contacts: for AWG cables for main contacts 2x (20 ... 16), 2x (18 ... 14), 2x 12
connectable conductor cross-section for main contacts: solid 0.5 ... 4 mm2
connectable conductor cross-section for main contacts: solid or stranded 0.5 ... 4 mm2
connectable conductor cross-section for main contacts: stranded 0.5 ... 4 mm2
connectable conductor cross-section for main contacts: finely stranded with core end processing 0.5 ... 2.5 mm2
connectable conductor cross-section for auxiliary contacts: solid or stranded 0.5 ... 4 mm2
connectable conductor cross-section for auxiliary contacts: finely stranded with core end processing 0.5 ... 2.5 mm2
for auxiliary contacts: solid 2x (0.5 ... 1.5 mm2), 2x (0.75 ... 2.5 mm2)
for auxiliary contacts: solid or stranded 2x (0.5 ... 1.5 mm2), 2x (0.75 ... 2.5 mm2), 2x 4 mm2
for auxiliary contacts: finely stranded with core end processing 2x (0.5 ... 1.5 mm2), 2x (0.75 ... 2.5 mm2)
for auxiliary contacts: for AWG cables for auxiliary contacts 2x (20 ... 16), 2x (18 ... 14), 2x 12
AWG number as coded connectable conductor cross section for main contacts 20 ... 12

Electrical Safety 2

protection class IP on the front according to IEC 60529 IP20
touch protection on the front according to IEC 60529 finger-safe, for vertical contact from the front

Communication/ Protocol 1

product function bus communication No

Approvals Certificates 1

Environmental Product Declaration: global warming potential [CO2 eq] / during manufacturing 1.15 kg

Logistics 7

Net weight 0.218 kg
Package dimensions 62 × 50 × 78 mm
Country of origin DE
Shipping weight 0.718 kg
Ships from Türkiye
Dispatch 12 Nov
Stock In stock

Source: manufacturer data · Last verified: 29 Oct 2026

Documents

Documents for 3RT2316-1AP00

No documents are on file for this part yet.

Ask us for the datasheet
Other ratings

All 9 ratings in Siemens 3RT2

Siemens Siemens 3RT2 series page →
Other ratings in the same series
Motor power Rated current Part number Model no Stock Dispatch Price Add to cart
18 A 3RT2316-1AP00 This part 3RT2 In stock $31.22
22 A 3RT2317-1AP00 3RT2 In stock $34.78
35 A 3RT2325-1AP00 3RT2 In stock $54.80
40 A 3RT2326-1AP00 3RT2 In stock $77.23
50 A 3RT2327-1AP00 3RT2 In stock $120.46
60 A 3RT2336-1AP00 3RT2 In stock $149.22
110 A 3RT2337-1AP00 3RT2 Low stock $205.44
140 A 3RT2346-1AP00 3RT2 Low stock $389.62
Certifications

Certifications and standards

  • EN 60715
Quick answers

Questions about the 3RT23

What is the rated current of 3RT23?

The rated current of 3RT23 is 18 A.

Which supply voltage is 3RT23 rated for?

The rated operational voltage of 3RT23 is 400 V AC.

What is the EAN of 3RT23?

The EAN (GTIN) of 3RT23 is 4011209845589.

Where does 3RT23 ship from, and how fast?

3RT23 ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival. Stock items are dispatched within 1–2 business days.

Guides

Guides for contactors

All guides for contactors
Reviews

Customer reviews

Series

Siemens Siemens 3RT2

Brand
Siemens
Series
Siemens 3RT2
Rated current
18–160 A
Supply voltage
400 V AC
Ratings listed
9
Series page →
Series

Other series in Contactors

$31.22 In stock · 12 Nov
Quote

Get a Quote

3RT23

Genuine parts

Genuine, factory-sealed parts

Siemens · 3RT2316-1AP00

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
Siemens and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.

Added to cart Could not add to cart

View cart