The Schneider Electric TPRSM001 is a TeSys island SIL interface module that implements a safe-stop function for compatible TPRSS SIL motor starters. It monitors an isolated 24 V DC switching input and drives a 1 NO potential-free relay output, meeting SIL 2 (IEC 61508), SILCL 2 (IEC 62061) and PL d category 2 (ISO 13849-1) in a single-channel architecture, and works only when connected to a TPRBC bus coupler.
Technical Specifications
| Reference | TPRSM001 |
| Brand | Schneider Electric |
| Range | TeSys island |
| Product Type | SIL interface module (safety relay) |
| Device Short Name | TPRSM |
| Product Compatibility | TPRBC bus coupler, TPRSS SIL motor starter |
| Input Type | Isolated switching input, safe stop |
| Input Voltage | 15-28.8 V DC (state 1); 0-5 V DC (state 0) |
| Output Type | Relay, instantaneous opening, 1 NO, potential free |
| Output Thermal Current | 8 A (relay output) |
| Protection Type | External fuse, 8 A gG, relay output |
| Rated Operational Voltage [Ue] | Input/output circuit 24 V DC |
| Rated Insulation Voltage [Ui] | 50 V |
| Rated Impulse Withstand Voltage [Uimp] | 2 kV (IEC 60947-1) |
| Safety Function | Safe stop category 0 and category 1 (IEC 60204-1) |
| Safety Integrity Level | SIL 2 (IEC 61508); SILCL 2 (IEC 62061); PL d category 2 (ISO 13849-1) |
| Rated Supply Voltage [Us] | 24 V DC, supplied by the bus coupler |
| Current Consumption | 10 mA |
| Mounting | 35 mm DIN rail (horizontal/vertical) |
| Dimensions (W x H x D) | 25 x 118 x 114 mm |
| Net Weight | 0.159 kg |
| IP Degree of Protection | IP20 |
| Ambient Operating Temperature | -10...60 °C |
| GTIN | 3606489832872 |
Certifications & Standards
- EAC (pending)
- UL
- CSA
- UL 60947-5-1
- IEC 60947-5-1
Selection Notes
The TPRSM001 only adds value when paired with a TPRSS SIL motor starter and a TPRBC bus coupler on the same TeSys island DIN rail run; on its own it has no starting or protection function. Its category 0 and category 1 safe-stop options (immediate power removal versus a controlled stop delay) let it match the stopping category the machine's risk assessment calls for, and the SIL 2 / PL d single-channel rating means it can be used directly in a safety function without an external safety PLC, provided the rest of the safety chain meets the same performance level.