The Schneider Electric LV847382 is an MN instantaneous undervoltage release for fixed MasterPact MTZ1, MTZ2, and MTZ3 air circuit breakers, supplied for 100-130 V AC 50/60 Hz or 100-130 V DC control circuits. It opens the breaker automatically once the supervised voltage falls to 0.35-0.7 Un, then re-closes the circuit once voltage recovers to 0.85 Un.
Pick the LV847382 when the circuit being supervised runs at 100-130 V AC or DC; the same MN release is also offered in 200-250 V and 380-480 V bands for higher control voltages, so matching this rating to the actual supply keeps the release from tripping immediately or never tripping at all. It only fits fixed-mounted MTZ1, MTZ2, and MTZ3 breakers, not drawout versions. Response time is 45 ms on MTZ1 and 95 ms on MTZ2/MTZ3, so coordinate it with upstream relay timing when it is used as a safety interlock rather than a simple undervoltage trip.
| Maximum response time | 45 ms on opening MasterPact MTZ1, 95 ms on opening MasterPact MTZ2, 95 ms on opening MasterPact MTZ3 |
|---|---|
| Range | MasterPact |
| Device short name | MN |
| Product or Component Type | Undervoltage release |
| Device Application | Safety |
| Range compatibility | Masterpact MasterPact MTZ1 circuit breaker, Masterpact MasterPact MTZ2 circuit breaker, Masterpact MasterPact MTZ3 circuit breaker |
| Voltage release type | Instantaneous |
| Control Type | Standard |
|---|---|
| [Un] voltage power supply | 100...130 V AC 50/60 Hz, 100...130 V DC |
| Threshold tripping voltage | 0.35...0.7 Un opening, 0.85 Un closing |
| Holding power consumption | 4.5 W |
| Circuit breaker mounting mode | Fixed |
| Warranty (in months) | 18 |
|---|
| Part number | LV847382 |
|---|---|
| Type designation | MN |
| Brand | Schneider Electric |
| Condition | New, factory sealed |
| Source | Schneider Electric and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| EAN | 3606480806575 |
| Unit Type of Package 1 | PCE |
|---|---|
| Nbr. of units in pkg. | 1 |
| Package 1 Height | 1.2 in (3.0 cm) |
| Package 1 Width | 3.1 in (8.0 cm) |
| Package 1 Length | 2.4 in (6.0 cm) |
| Package weight(Lbs) | 6.1 oz (174.0 g) |
| Shipping weight | 0.174 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 30 Oct 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated operational voltage of MN is 100–130 V AC.
The tariff (HS) code on file for MN is 853890.
The EAN (GTIN) of MN is 3606480806575.
MN ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
Source ACB accessories fast with verified OEM parts, lead times, authenticity checks, and stocking strategy to cut downtime on Emax 2 frames. Shop at...
Compare 1600-2500A ACB platforms: ABB Emax 2, Schneider MTZ2, Siemens 3WL2 on breaking capacity, trip units, endurance and lifecycle cost. Shop at Stoklink.
ABB Emax 2 air circuit breaker selection, sizing, trip units, selectivity, and maintenance guide for 630 to 6300 A LV switchgear engineers. Shop at...