- Home
- All Collections
- Timer Relays
Timer Relays
ABB 1SVR500020R1100 CT-MFD.21 Multifunction Timer Relay 2C/O 12-240V AC/DC 5A 250V
Schneider Electric RE10RCMUN Harmony Timer Relay Off-Delay 0.1s-30h 24V AC/DC 240V AC 1 CO Timer Relay
Schneider Electric RENF22R2MMW Harmony NFC Timer Relay 8A 2CO 0.05s-999h 24-240V Multifunction Timer Relay
Schneider Electric RE10RQM7N Harmony Timer Relay Star-Delta 2-120s 240V AC 1NO+1NO Timer Relay
Schneider Electric RE10RAMUN Harmony Timer Relay On-Delay 0.1s-30h 24V AC/DC 240V AC 1 CO Timer Relay
Siemens 3RP2576-1NW30 3RP2 240V Relay
Siemens 3RP2574-1NW30 3RP2 240V Relay
Siemens 3RP2555-1AW30 3RP2 240V Relay
Siemens 3RP2540-1AW30 3RP2 240V Relay
Siemens 3RP2535-1AW30 3RP2 240V Relay
Siemens 3RP2525-1BW30 3RP2 240V Relay
Siemens 3RP2525-1AW30 3RP2 240V Relay
Siemens 3RP2513-1AW30 3RP2 240V Relay
Siemens 3RP2512-1AW30 3RP2 240V Relay
Siemens 3RP2511-1AW30 3RP2 240V Relay
Siemens 3RP2505-1BW30 3RP2 240V Relay
Siemens 3RP2505-1AW30 3RP2 240V Relay
Schneider Electric LADT2 TeSys Deca Pneumatic Time Delay Attachment for Contactors
Schneider Electric RE48ATM12MW Harmony RE48 5A 2CO On-Delay Timer Relay
Schneider Electric RE48AML12MW Harmony RE48A 5A 2CO Multifunction Timer Relay
Timer relays from ABB, Siemens and Schneider Electric provide on-delay, off-delay, flasher and star-delta timing for control panels. The range includes ABB CT-S, CT-D and CT-C types, Siemens 3RP2 and Harmony timer relays, with contact ratings from 0.7 A to 16 A. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- Multifunction timer relays that combine several time functions in one unit, such as ABB CT-MFD and CT-MVS or Harmony RE22 and RE48.
- Star-delta timers for motor starting, for example ABB CT-SDD.
- Flasher and asymmetrical flashing timers.
- Siemens SIRIUS 3RP2 timing relays with universal supply voltage.
- Staircase light switches with timing function.
How to choose
- Time function: on-delay, off-delay, pulse, flasher or star-delta.
- Time range: select a range where your required delay is not at the extreme ends of the dial.
- Supply voltage: 24-48 V DC with 24-240 V AC universal supply is common.
- Contact output: one or two C/O contacts and the load current at 250 V.
- Width and mounting: DIN rail modules or 8-pin and 11-pin plug-in formats.
FAQ
When do I need a star-delta timer?
When a squirrel-cage motor starts in star and then switches to delta. The timer sets the changeover delay and a short pause between the two contactors.
What is a multifunction timer relay?
A single device where you select among several time functions with a rotary switch. It reduces the number of part numbers you stock for spares.
Do you quote timer relays in volume?
Stoklink ships worldwide from Turkey, EXW. Lead time depends on distributor stock, and project quantities are quoted on request.