- Home
- All Collections
- Switch Disconnectors & Transfer Switches
Switch Disconnectors & Transfer Switches
Switch Disconnectors & Transfer Switches Categories
Switch Disconnectors & Transfer Switches
Siemens 3LD3248-0TK51 3LD3 32A 3P 400V Switch Disconnector
Siemens 3LD3230-0TK11 3LD3 32A 3P 400V Switch Disconnector
Siemens 3LD3154-0TK51 3LD3 25A 3P 400V Switch Disconnector
Siemens 3LD3148-0TK51 3LD3 25A 3P 400V Switch Disconnector
Siemens 3LD3130-0TK11 3LD3 25A 3P 400V Switch Disconnector
Siemens 3LD3054-0TL51 3LD3 16A 4P 400V Switch Disconnector
Siemens 3LD3054-0TK51 3LD3 16A 3P 400V Switch Disconnector
Siemens 3LD3048-0TL51 3LD3 16A 4P 400V Switch Disconnector
Siemens 3LD3048-0TK51 3LD3 16A 3P 400V Switch Disconnector
Siemens 3LD3030-0TL11 3LD3 16A 4P 400V Switch Disconnector
Siemens 3LD3030-0TK11 3LD3 16A 3P 400V Switch Disconnector
Siemens 3LD2866-0TB51 3LD2 125A 3P 400V Switch Disconnector
Siemens 3LD2814-0TK51 3LD2 125A 3P 400V Switch Disconnector
Siemens 3LD2804-0TK51 3LD2 125A 3P 400V Switch Disconnector
Siemens 3LD2766-0TB51 3LD2 100A 3P 400V Switch Disconnector
Siemens 3LD2714-0TK51 3LD2 100A 3P 400V Switch Disconnector
Siemens 3LD2704-0TK51 3LD2 100A 3P 400V Switch Disconnector
Siemens 3LD2565-0TB51 3LD2 63A 3P 400V Switch Disconnector
Siemens 3LD2514-0TK51 3LD2 63A 3P 400V Switch Disconnector
Siemens 3LD2504-0TK51 3LD2 63A 3P 400V Switch Disconnector
Switch disconnectors and transfer switches from ABB, Siemens, Schneider Electric and Mersen, covering isolation, manual changeover, automatic transfer and cam switching from 6 A up to 3800 A. The range includes 1P to 4P devices, with 3P and 4P the most common. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- Switch Disconnectors – load-break isolators for panels and machines, including handles, shafts and interlocks.
- Changeover Switches (Manual & Motorized) – select between two supplies, such as mains and generator.
- Automatic Transfer Switches (ATS) – controller-driven transfer, including TransferPacT and ABB OXB and OTM units.
- Cam Switches – Harmony K rotary switches for control, metering and small loads.
How to choose
- Rated current and utilization category. Match the AC-22 or AC-23 duty to the load, and size for the full load current.
- Pole count. Use 4P where the neutral must be switched, for example when changing between two sources.
- Voltage and short-circuit withstand. Check the rating against the fault level at the installation point.
- Control method. Manual operation suits most panels. Choose motorized or automatic transfer when the change must happen without an operator.
- Mounting. Pick DIN-rail, base, door-coupled or enclosed to fit the panel layout.
FAQ
What is the difference between a switch disconnector and a circuit breaker?
A switch disconnector isolates and switches load current but gives no overcurrent protection. A circuit breaker also trips on overload and short circuit, so a protective device is normally installed upstream of the switch.
When should I use an ATS instead of a manual changeover switch?
Use an ATS when the transfer must happen automatically after a mains failure, for example to a generator. A manual changeover switch needs an operator and suits sites where short outages are acceptable.
Do you ship outside Turkey?
Yes. Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, and we quote project quantities on request.