- Home
- All Collections
- Switch Disconnectors & Transfer Switches
Switch Disconnectors & Transfer Switches
Switch Disconnectors & Transfer Switches Categories
Switch Disconnectors & Transfer Switches
Siemens 3NG1302 3NG1 400A Switch Disconnector
Siemens 3NG1202 3NG1 250A Switch Disconnector
Siemens 3NG1002 3NG1 160A Switch Disconnector
Siemens 3LD9344-5C 3LD9 Switch Disconnector
Siemens 3LD9344-4C 3LD9 Switch Disconnector
Siemens 3LD9344-3CA 3LD9 Switch Disconnector
Siemens 3LD9344-3C 3LD9 Switch Disconnector
Siemens 3LD9344-2CA 3LD9 Switch Disconnector
Siemens 3LD9344-2C 3LD9 Switch Disconnector
Siemens 3LD9341-2A 3LD9 Switch Disconnector
Siemens 3LD9341-0A 3LD9 Switch Disconnector
Siemens 3LD9340-6B 3LD9 6A Switch Disconnector
Siemens 3LD9340-3B 3LD9 Switch Disconnector
Siemens 3LD9340-2B 3LD9 Switch Disconnector
Siemens 3LD9286-4A 3LD9 Switch Disconnector
Siemens 3LD9286-1A 3LD9 Switch Disconnector
Siemens 3LD9284-1B 3LD9 63A Switch Disconnector
Siemens 3LD9280-0C 3LD9 100A Switch Disconnector
Siemens 3LD9280-0B 3LD9 100A Switch Disconnector
Siemens 3LD9250-0CA 3LD9 63A Switch Disconnector
Switch disconnectors and transfer switches from ABB, Siemens, Schneider Electric and Mersen, covering isolation, manual changeover, automatic transfer and cam switching from 6 A up to 3800 A. The range includes 1P to 4P devices, with 3P and 4P the most common. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- Switch Disconnectors – load-break isolators for panels and machines, including handles, shafts and interlocks.
- Changeover Switches (Manual & Motorized) – select between two supplies, such as mains and generator.
- Automatic Transfer Switches (ATS) – controller-driven transfer, including TransferPacT and ABB OXB and OTM units.
- Cam Switches – Harmony K rotary switches for control, metering and small loads.
How to choose
- Rated current and utilization category. Match the AC-22 or AC-23 duty to the load, and size for the full load current.
- Pole count. Use 4P where the neutral must be switched, for example when changing between two sources.
- Voltage and short-circuit withstand. Check the rating against the fault level at the installation point.
- Control method. Manual operation suits most panels. Choose motorized or automatic transfer when the change must happen without an operator.
- Mounting. Pick DIN-rail, base, door-coupled or enclosed to fit the panel layout.
FAQ
What is the difference between a switch disconnector and a circuit breaker?
A switch disconnector isolates and switches load current but gives no overcurrent protection. A circuit breaker also trips on overload and short circuit, so a protective device is normally installed upstream of the switch.
When should I use an ATS instead of a manual changeover switch?
Use an ATS when the transfer must happen automatically after a mains failure, for example to a generator. A manual changeover switch needs an operator and suits sites where short outages are acceptable.
Do you ship outside Turkey?
Yes. Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, and we quote project quantities on request.