Filter

Switch Disconnectors & Transfer Switches Categories

Switch Disconnectors & Transfer Switches

Filter
Showing 1 - 280 of 552 items

Siemens 3LD9250-0BA 3LD9 63A Switch Disconnector

Reference No: 3LD9250-0BA
Catalog No: 3LD9250-0BA
Rated Current (A): 63
12 pcs in stock
$18.79

Siemens 3LD9245-2C 3LD9 Switch Disconnector

Reference No: 3LD9245-2C
Catalog No: 3LD9245-2C
0 pcs in stock
$32.33

Siemens 3LD9243-1B 3LD9 160A Switch Disconnector

Reference No: 3LD9243-1B
Catalog No: 3LD9243-1B
Rated Current (A): 160
0 pcs in stock
$78.26

Siemens 3LD9240-0C 3LD9 160A Switch Disconnector

Reference No: 3LD9240-0C
Catalog No: 3LD9240-0C
Rated Current (A): 160
0 pcs in stock
$90.93

Siemens 3LD9240-0B 3LD9 160A Switch Disconnector

Reference No: 3LD9240-0B
Catalog No: 3LD9240-0B
Rated Current (A): 160
0 pcs in stock
$91.08

Siemens 3LD9224-1B 3LD9 25A Switch Disconnector

Reference No: 3LD9224-1B
Catalog No: 3LD9224-1B
Rated Current (A): 25
0 pcs in stock
$15.63

Siemens 3LD9220-0C 3LD9 32A Switch Disconnector

Reference No: 3LD9220-0C
Catalog No: 3LD9220-0C
Rated Current (A): 32
4 pcs in stock
$12.37

Siemens 3LD9220-0B 3LD9 32A Switch Disconnector

Reference No: 3LD9220-0B
Catalog No: 3LD9220-0B
Rated Current (A): 32
3 pcs in stock
$12.37

Siemens 3LD9205-2C 3LD9 Switch Disconnector

Reference No: 3LD9205-2C
Catalog No: 3LD9205-2C
17 pcs in stock
$16.46

Siemens 3LD9200-5C 3LD9 6A Switch Disconnector

Reference No: 3LD9200-5C
Catalog No: 3LD9200-5C
Rated Current (A): 6
35 pcs in stock
$14.92

Siemens 3LD9200-5B 3LD9 6A Switch Disconnector

Reference No: 3LD9200-5B
Catalog No: 3LD9200-5B
Rated Current (A): 6
43 pcs in stock
$14.92

Siemens 3LD9200-2C 3LD9 16A Switch Disconnector

Reference No: 3LD9200-2C
Catalog No: 3LD9200-2C
Rated Current (A): 16
2 pcs in stock
$11.60

Siemens 3LD9200-2B 3LD9 16A Switch Disconnector

Reference No: 3LD9200-2B
Catalog No: 3LD9200-2B
Rated Current (A): 16
9 pcs in stock
$13.37

Siemens 3LD3454-0TK51 3LD3 63A 3P 400V Switch Disconnector

Reference No: 3LD3454-0TK51
Catalog No: 3LD3454-0TK51
Rated Current (A): 63
Rated Voltage (VAC): 400 V
Number of Poles: 3P
23 pcs in stock
$50.86

Siemens 3LD3448-0TK51 3LD3 63A 3P 400V Switch Disconnector

Reference No: 3LD3448-0TK51
Catalog No: 3LD3448-0TK51
Rated Current (A): 63
Rated Voltage (VAC): 400 V
Number of Poles: 3P
0 pcs in stock
$82.34

Siemens 3LD3430-0TK11 3LD3 63A 3P 400V Switch Disconnector

Reference No: 3LD3430-0TK11
Catalog No: 3LD3430-0TK11
Rated Current (A): 63
Rated Voltage (VAC): 400 V
Number of Poles: 3P
1 pcs in stock
$52.50

Siemens 3LD3354-0TK51 3LD3 40A 3P 400V Switch Disconnector

Reference No: 3LD3354-0TK51
Catalog No: 3LD3354-0TK51
Rated Current (A): 40
Rated Voltage (VAC): 400 V
Number of Poles: 3P
1 pcs in stock
$58.18

Siemens 3LD3348-0TK51 3LD3 40A 3P 400V Switch Disconnector

Reference No: 3LD3348-0TK51
Catalog No: 3LD3348-0TK51
Rated Current (A): 40
Rated Voltage (VAC): 400 V
Number of Poles: 3P
0 pcs in stock
$71.40

Siemens 3LD3330-0TK11 3LD3 40A 3P 400V Switch Disconnector

Reference No: 3LD3330-0TK11
Catalog No: 3LD3330-0TK11
Rated Current (A): 40
Rated Voltage (VAC): 400 V
Number of Poles: 3P
4 pcs in stock
$42.76

Siemens 3LD3254-0TK51 3LD3 32A 3P 400V Switch Disconnector

Reference No: 3LD3254-0TK51
Catalog No: 3LD3254-0TK51
Rated Current (A): 32
Rated Voltage (VAC): 400 V
Number of Poles: 3P
0 pcs in stock
$38.04

Switch disconnectors and transfer switches from ABB, Siemens, Schneider Electric and Mersen, covering isolation, manual changeover, automatic transfer and cam switching from 6 A up to 3800 A. The range includes 1P to 4P devices, with 3P and 4P the most common. Stoklink ships worldwide from Turkey and quotes project volumes on request.

What's in this range

How to choose

  • Rated current and utilization category. Match the AC-22 or AC-23 duty to the load, and size for the full load current.
  • Pole count. Use 4P where the neutral must be switched, for example when changing between two sources.
  • Voltage and short-circuit withstand. Check the rating against the fault level at the installation point.
  • Control method. Manual operation suits most panels. Choose motorized or automatic transfer when the change must happen without an operator.
  • Mounting. Pick DIN-rail, base, door-coupled or enclosed to fit the panel layout.

FAQ

What is the difference between a switch disconnector and a circuit breaker?

A switch disconnector isolates and switches load current but gives no overcurrent protection. A circuit breaker also trips on overload and short circuit, so a protective device is normally installed upstream of the switch.

When should I use an ATS instead of a manual changeover switch?

Use an ATS when the transfer must happen automatically after a mains failure, for example to a generator. A manual changeover switch needs an operator and suits sites where short outages are acceptable.

Do you ship outside Turkey?

Yes. Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, and we quote project quantities on request.