- Home
- All Collections
- Power Contactors (AC-3)
Power Contactors (AC-3)
Schneider Electric LP1K0910FD TeSys K Contactor 3P 1NO Aux 9 A AC-3 110 V DC Coil Contactor
Schneider Electric LP1K0910BD LP1K 3-Pole 9A 24V DC Coil TeSys K Contactor
Schneider Electric LP1K0901ED TeSys K Contactor 3P 1NC Aux 9 A AC-3 48 V DC Coil Contactor
Schneider Electric LP1K0901BD TeSys K 3-Pole 9A 440V 24VDC Coil AC Contactor
Schneider Electric LP1K0610ED TeSys K Contactor 3P 1NO Aux 6 A AC-3 48 V DC Coil Contactor
Schneider Electric LP1K0610BD TeSys K LP1K 3-Pole 6A 24V DC Coil AC Contactor
Schneider Electric LP1K0601ED TeSys K Contactor 3P 1NC Aux 6 A AC-3 48 V DC Coil Contactor
Schneider Electric LP1K0601BD TeSys K 3-Pole 6A 440V 24V DC Coil Contactor
Schneider Electric LC1K1610Q7 TeSys K Contactor 3P 3NO AC-3 16 A 1NO Aux 380-400 V AC Coil Contactor
Schneider Electric LC1K1610M7 TeSys K 3P 16A 440V AC Contactor
Schneider Electric LC1K1610B7 TeSys K 3-Pole 16A 440V AC Contactor
Schneider Electric LC1K1601M7 TeSys K 3P 16A 440V AC Contactor
Schneider Electric LC1K1601F7 TeSys K Contactor 3P 3NO AC-3 16 A 1NC Aux 110 V AC Coil Contactor
Schneider Electric LC1K1601B7 TeSys K 3P 16A 440V AC Contactor
Schneider Electric LC1K1210M7 TeSys K 3-Pole 12A 440V Coil 220V AC Contactor
Schneider Electric LC1K1210F7 TeSys K Contactor 3P 3NO AC-3 12 A 1NO Aux 110 V AC Coil Contactor
Schneider Electric LC1K1210E7 TeSys K Contactor 3P 3NO AC-3 12 A 1NO Aux 48 V AC Coil Contactor
Schneider Electric LC1K1210B7 TeSys K 3-Pole 12A 440V Coil 24V AC Contactor
Schneider Electric LC1K1201M7 TeSys K 3P 12A AC-3 5.5kW 220V Coil Contactor
Schneider Electric LC1K1201F7 TeSys K Contactor 3P 3NO AC-3 12 A 1NC Aux 110 V AC Coil Contactor
Power contactors (AC-3) from ABB, Schneider Electric and Siemens start and stop three-phase motors and switch heavy loads. The range covers over 650 products from 6 A to 2650 A, with motor ratings from 2.2 kW to 450 kW, mostly in 3 and 4 pole versions. Stoklink ships worldwide from Turkey and quotes project volumes on request.
What's in this range
- ABB AF Contactors – 3 and 4 pole AF series with wide-range AC/DC coils.
- Schneider TeSys Deca Contactors – the largest series here, from 9 A to 200 A.
- Schneider TeSys Giga Contactors – high-current frames from 115 A to 800 A.
- Schneider TeSys K Contactors – compact contactors for 6 A to 16 A.
- Schneider Easy TeSys Contactors – general-purpose contactors from 6 A to 630 A.
- Siemens SIRIUS 3RT2 Contactors and Siemens SIRIUS 3RT1 Contactors – SIRIUS frames from small to very large.
How to choose
- Motor power and current in AC-3 at your supply voltage. Do not size from the AC-1 value.
- Pole count: 3P for motors, 4P where the neutral is switched.
- Coil voltage and type, AC or DC, against the control supply.
- Short-circuit protection and overload relay matched to the contactor, following the manufacturer's coordination tables.
- Auxiliary contact needs and whether add-on blocks fit the frame.
FAQ
What does AC-3 mean on a contactor?
AC-3 is the IEC 60947-4-1 category for starting and stopping squirrel-cage motors. Ratings in AC-3 are usually lower than AC-1 for the same frame.
Can I replace a contactor with another brand?
Check rated current in AC-3, pole count, coil voltage and mounting dimensions. Auxiliary contacts and coordination with the overload relay must also match.
Do you ship contactors outside Turkey?
Yes. Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so send the part numbers for a quote. Project quantities are quoted on request.